Publications and source records attributed to Eugene E Gualtieri.

5 recordsLinked to original sources

Spatial and temporal characteristics of physiological noise in fMRI at 3T.

RATIONALE AND OBJECTIVES: Physiological noise in blood oxygen level-dependent functional magnetic resonance imaging (BOLD fMRI) has been shown to have characteristics similar to the BOLD signal itself, suggesting that it may have a vascular dependence. In this study, we evaluated the influence of physiological noise in fMRI as revealed by the differences in vasculature sensitivity of gradient-echo echo-planar imaging (GE-EPI) and spin-echo EPI (SE-EPI). MATERIALS AND METHODS: The contribution of physiological noise to the fMRI signal during activation of the visual cortex was assessed by comparing its temporal characteristics with respect to echo time (TE), using both GE-EPI and SE-EPI. The correlation of the noise in fMRI with apparent diffusion coefficient (ADC) and the number of components required to describe its variance, as determined by principal-component analysis (PCA), were also assessed. RESULTS: The SE-EPI data were less affected by a TE-dependence of noise, in contrast to the apparent physiological noise in GE-EPI. Voxel-wise analysis revealed that total apparent noise increased as ADC values increased, and the relationship was different for GE-EPI and SE-EPI. PCA revealed that while the number of components characterizing the noise in SE-EPI data increased in a TE-dependent manner, approaching that of white noise at long echo time, the number of components from GE-EPI data was TE-independent. CONCLUSIONS: The difference in sensitivities to physiological noise between SE-EPI and GE-EPI suggests that extravascular BOLD processes around draining veins contribute significantly to physiological noise in BOLD fMRI, and the suppression of this noise component may enhance SE-EPI BOLD sensitivity at higher fields.

Echo-Planar Imaging↗

Spatial sensitivity and temporal response of spin echo and gradient echo bold contrast at 3 T using peak hemodynamic activation time.

Recent theoretical and experimental work has suggested that spin echo (SE) functional MRI (fMRI) has improved localization of neural activity compared to gradient echo (GE) fMRI at high field strengths, albeit with a decrease in blood oxygenation level-dependent (BOLD) contrast. The present study investigated spatial and temporal variations in GE and SE fMRI at 3 T in response to a brief visual stimulus. The results demonstrate that SE BOLD contrast reaches its maximum amplitude more quickly than does GE contrast at long echo times. We have called this metric the peak hemodynamic activation time (PHAT). Because BOLD changes in response to increased neuronal activity occur earlier in the microvasculature and then later propagate into the venous compartment, these results provide further evidence that SE-based BOLD contrast provides superior localization to the site of activation at 3 T. Spatial overlay of SE and GE PHAT maps onto structural images reveal markedly different spatial profiles and further support the interpretation that shorter peak times correlate to improved spatial sensitivity.

Artifacts↗

Temporal resolving power of spin echo and gradient echo fMRI at 3T with apparent diffusion coefficient compartmentalization.

The temporal resolving power of blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) at 3T was investigated in the visual and auditory cortices of the human brain. By using controlled temporal delays and selective visual hemifield stimulation, regions with similar (left vs. right occipital cortex) and different (occipital cortex vs. auditory cortex) vascular architectures were compared. Estimates of the time-to-peak (TTP) of the BOLD hemodynamic response function (hrf) were obtained using a spin echo (SE) sequence and compared to those acquired using a traditional gradient echo (GE) sequence. The hrf TTP in the visual cortex was found to be 4.73 s and 4.21 s for GE and SE, respectively. The auditory cortex response was significantly delayed, with TTPs of 4.95 s and 4.51 s for GE and SE, respectively. The GE response was able to resolve visual stimuli separated by 250 ms, whereas SE could resolve stimuli 500 ms apart. Apparent-diffusion-coefficient (ADC) compartmentalization of the BOLD signal was applied to restrict the vascular sensitivity of the SE and GE sequences. Limiting the response to voxels with ADCs < 0.8 x 10(-3) mm(2)/s improved the temporal resolving power of GE and SE BOLD to 125 ms and 250 ms, respectively.

Acoustic Stimulation↗

T1rho contrast in functional magnetic resonance imaging.

The application of T1 in the rotating frame (T1rho) to functional MRI in humans was studied at 3 T. Increases in neural activity increased parenchymal T1rho. Modeling suggested that cerebral blood volume mediated this increase. A pulse sequence named spin-locked echo planar imaging (SLEPI) that produces both T1rho and T2* contrast was developed and used in a visual functional MRI (fMRI)experiment. Spin-locked contrast significantly augments the T2* blood oxygen level-dependent (BOLD) contrast in this sequence. The total functional contrast generated by the SLEPI sequence (1.31%) was 54% larger than the contrast (0.85%) obtained from a conventional gradient-echo EPI sequence using echo times of 30 ms. Analysis of image SNR revealed that the spin-locked preparation period of the sequence produced negligible signal loss from static dephasing effects. The SLEPI sequence appears to be an attractive alternative to conventional BOLD fMRI, particularly when long echo times are undesirable, such as when studying prefrontal cortex or ventral regions, where static susceptibility gradients often degrade T2*-weighted images.

Algorithms↗

The effects of geometric distortion correction on motion realignment in fMRI.

RATIONALE AND OBJECTIVES: Subject motion is well recognized as a significant impediment to resolution and sensitivity in functional magnetic resonance imaging (fMRI). A parallel confounder to fMRI data quality is geometric image distortion, particularly at high field strengths, due to susceptibility-induced magnetic field inhomogeneity. Consequently, many high-field echo-planar imaging methods incorporate a post-processing distortion correction by acquiring a field map of the sample prior to the fMRI measurement. However, field mapping methods impose a spatial mask on the data, since field information is only obtainable from regions with adequate signal-to-noise ratio (SNR). This masking, when applied to subsequent images in the fMRI time series, can clip the effects of motion, resulting in inaccurate estimation and correction of motion-based changes in the images. MATERIALS AND METHODS: The effects of geometric distortion correction on automated realignment (motion correction) of fMRI data are investigated from data acquired at 4 T. The results of image realignment with and without prior application of distortion correction are compared, using the estimated motion parameters and overall image realignment as metrics. RESULTS: The application of field-map-based distortion correction prior to image realignment reduces the amount of motion detected by a standard motion correction algorithm. Moreover, motion correction applied before distortion correction is shown to result in superior realignment of motion-correction images. CONCLUSION: It is preferable to perform motion realignment prior to correcting for geometric distortion.

Humans↗