PubMed Health⌕ Search

Biomedical subjects

Eugene Kozlov

Publications and source records attributed to Eugene Kozlov.

4 recordsLinked to original sources

Real-time cell dynamics with a multianalyte physiometer.

A technique for simultaneously measuring changes in extracellular glucose, lactate, and oxygen concentrations in conjunction with acidification rates on a Cytosensor Microphysiometer is described. Platinum electrodes are inserted into the standard Cytosensor plunger head and modified with enzymes and biocompatible polymeric films. The lactate and glucose oxidase enzymes catalyze the reaction of lactate and glucose. An end product of these catalyses, H2O2, is measured amperometrically. Extracellular oxygen is also measured amperometrically, while the acidification rate is measured potentiometrically by the Cytosensor. Useful information is obtained during the Cytosensor stop-flow cycles, which produce increasing or decreasing peaks, owing to the production of lactic and carbonic acid and consumption of glucose and oxygen by the cells. Fabrication of the modified sensor head and deposition of the electrode films is detailed, and the operation of the technique is described and illustrated by the simultaneous measurement of all four analytes during the addition of 20 mM fluoride to mouse fibro blast cells.

Animals↗

A microphysiometer for simultaneous measurement of changes in extracellular glucose, lactate, oxygen, and acidification rate.

A microphysiometer capable of measuring changes in extracellular glucose, lactate, oxygen, and acidification rate has been developed by incorporating modified electrodes into a standard Cytosensor Microphysiometer plunger. Glucose and lactate are measured indirectly at platinum electrodes by amperometric oxidation of hydrogen peroxide, which is produced from catalysis of glucose and lactate at films containing their respective entrapped oxidase. Oxygen is measured amperometrically at a platinum electrode coated with a Nafion film, while the acidification rate is measured potentiometrically by a Cytosensor Microphysiometer. Analytical information is obtained during the Cytosensor stop-flow cycles, where the electrodes measure changes in the extracellular medium corresponding to the consumption or production of the analyte by the cells. Modification of the Cytosensor plunger for multianalyte determination is described, and the operation of the technique is illustrated by the simultaneous measurement of all four analytes during the addition of fluoride and DNP to Chinese hamster ovary cells and fluoride and antimycin A to mouse fibroblast cells. Cell metabolic recovery and dynamics after exposure to agents can also be observed in specific cases.

Animals↗

NanoLiterBioReactor: long-term mammalian cell culture at nanofabricated scale.

There is a need for microminiaturized cell-culture environments, i.e. NanoLiter BioReactors (NBRs), for growing and maintaining populations of up to several hundred cultured mammalian cells in volumes three orders of magnitude smaller than those contained in standard multi-well screening plates. These devices would enable the development of a new class of miniature, automated cell-based bioanalysis arrays for monitoring the immediate environment of multiple cell lines and assessing the effects of drug or toxin exposure. We fabricated NBR prototypes, each of which incorporates a culture chamber, inlet and outlet ports, and connecting microfluidic conduits. The fluidic components were molded in polydimethylsiloxane (PDMS) using soft-lithography techniques, and sealed via plasma activation against a glass slide, which served as the primary culture substrate in the NBR. The input and outlet ports were punched into the PDMS block, and enabled the supply and withdrawal of culture medium into/from the culture chamber (10-100 nL volume), as well as cell seeding. Because of the intrinsically high oxygen permeability of the PDMS material, no additional CO(2)/air supply was necessary. The developmental process for the NBR typically employed several iterations of the following steps: Conceptual design, mask generation, photolithography, soft lithography, and proof-of-concept culture assay. We have arrived at several intermediate designs. One is termed "circular NBR with a central post (CP-NBR)," another, "perfusion (grid) NBR (PG-NBR)," and a third version, "multitrap (cage) NBR (MT-NBR)," the last two providing total cell retention. Three cells lines were tested in detail: a fibroblast cell line, CHO cells, and hepatocytes. Prior to the culturing trials, extensive biocompatibility tests were performed on all materials to be employed in the NBR design. To delineate the effect of cell seeding density on cell viability and survival, we conducted separate plating experiments using standard culture protocols in well-plate dishes. In both experiments, PicoGreen assays were used to evaluate the extent of cell growth achieved in 1-5 days following the seeding. Low seeding densities resulted in the absence of cell proliferation for some cell lines because of the deficiency of cell-cell and extracellular matrix (ECM)-cell contacts. High viabilities were achieved in all designs. We conclude that an instrumented microfluidics-based NanoBioReactor (NBR) will represent a dramatic departure from the standard culture environment. The employment of NBRs for mammalian cell culture opens a new paradigm of cell biology, so far largely neglected in the literature.

Animals↗

Nanoparticulate system for efficient gene transfer into refractory cell targets.

A biocompatible, nanoparticulate formulation has been designed to retain, protect, and deliver adenoviral gene constructs over an extended time course. Such devices can be administered locally or systemically with low toxicity. A multipolymeric nanoparticulate system, featuring very high stability in physiologic media, was designed to allow efficient in vitro gene transfer. The efficacy of nanoparticulate delivery is effective in cell systems that are normally refractory to gene transfer, such as pancreatic islets and antigen-presenting cells. The findings suggest a nonspecific uptake system that permits adenoviral particle release within the transfected cells. A comparison with literature data revealed that our system is efficient at much lower levels (at least three orders of magnitude) of infectious viral particles.

Animals↗