Volumetric cartilage measurements of porcine knee at 1.5-T and 3.0-T MR imaging: evaluation of precision and accuracy.

PURPOSE: To compare the precision and accuracy of 3.0-T and 1.5-T magnetic resonance (MR) imaging in the quantification of cartilage volume by using direct volumetric measurements as a reference standard. MATERIALS AND METHODS: The local animal experimentation committee did not require its approval for this study. Porcine knees were obtained from an abattoir. These specimens were used to optimize imaging parameters regarding effective signal-to-noise ratio (SNRE) and contrast-to-noise ratio (CNRE) for a fat-saturated spoiled gradient-recalled acquisition in the steady state (SPGR) sequence, a water excitation SPGR sequence, and a fast spin-echo sequence at 3.0 T and a fat-saturated SPGR sequence at 1.5 T. By using the optimized sequences, 18 specimens were imaged in less than 6 minutes per sequence. A fivefold repetition of measurements of four specimens was performed for precision analysis. Cartilage was segmented by using semiautomatic software to calculate the volume. After imaging, the cartilage was scraped off and the volume was measured directly by using a saline-displacement method to calculate accuracy. Precision and accuracy errors were calculated as the root-mean-squares of the single errors per specimen. RESULTS: SNRE and CNRE values, respectively, were highest for the water excitation sequence at 3.0 T (1.81 sec(-1/2) and 1.27 sec(-1/2)), followed by the fat-saturated SPGR sequence (1.52 sec(-1/2) and 1.07 sec(-1/2)). The fast spin-echo sequence and the fat-saturated SPGR sequence at 1.5 T had lower SNR(E) (1.27 sec(-1/2) and 0.59 sec(-1/2), respectively). Accuracy error for MR-based volume calculation at the femur was 5.0%, 3.0%, 21%, and 16% for the water excitation, fat-saturated SPGR, and fast spin-echo sequences at 3.0 T and the fat-saturated SPGR sequence at 1.5 T, respectively. CONCLUSION: MR imaging at 3.0 T was shown in our study to better quantify cartilage volume. SNRE and CNRE were substantially improved, resulting in significantly higher accuracy in determining cartilage volume.

Animals↗

Computer-aided quantification of focal cartilage lesions of osteoarthritic knee using MRI.

Noninvasive assessment of articular cartilage using magnetic resonance imaging (MRI) has gained popularity in the diagnosis of osteoarthritis (OA), a condition that affects 20 million Americans. Focal cartilage lesions, a defect found in roughly 19% of the OA population, currently can only be evaluated with confidence using minimally invasive arthroscopy. This article presents a computer-aided procedure using MRI to quantify focal cartilage lesions and aims to support clinical practices of diagnosis and monitoring of lesion progress. Upon a local minima search for identifying focal lesions, the proposed gradient peak method outlines lesion boundaries and then generates morphological properties, such as lesion volume and lesion area. The procedure was evaluated using simulated and in vivo data. First, a simulated lesion was created and analyzed, and the results were compared with the exact solutions. Second, an in vivo evaluation was carried out on seven human knees in which nine focal lesions were identified and quantified. Three of the subjects had follow-up analyses, at either 1 or 2 years. Finally, in an attempt to characterize local biochemical changes underlying focal lesions, MR-derived T2 values of defective cartilage within the lesion boundaries were examined and compared with the values of adjacent cartilage compartments.

Aged↗

A three-dimensional MRI analysis of knee kinematics.

PURPOSE: To quantify normal, in vivo tibio-femoral knee joint kinematics in multiple weight bearing positions using non-invasive, high-resolution MRI and discuss the potential of developing future kinematic methods to assess patients with abnormal joint pathologies. METHODS: Ten volunteers with clinically normal knees pushed inferiorly on the footplate of a weight bearing apparatus inside the MR scanner. The volunteers held the weight (133 N) for five scans as the knee motion was evaluated from 0 degrees to 60 degrees of flexion. Full extension was set as the zero point for all measured parameters. Using 3D reconstructions, tibia motion relative to the femur and flexion angle was measured as varus-valgus angle, axial rotation, anterior-posterior translation, and medial-lateral translation. Medial and lateral compartment tibio-femoral contact areas were examined and centroids of the contract areas were calculated. RESULTS: Tibial internal rotation averaged 4.8 degrees at 40 degrees of flexion and then decreased. Tibial valgus increased by 8 degrees at 60 degrees of flexion. Femoral roll back also increased to 18.5 mm average at 60 degrees of flexion, while the tibia translated medially 2.5 mm. Medial compartment femoro-tibial contact area started at 374 mm2 and decreased to 308 mm2 with flexion of 60 degrees, while lateral compartment contact area did not change significantly from 276 mm2. CONCLUSIONS: Results correlate with previous studies of knee kinematics while providing greater three-dimensional detail. MR imaging allows excellent non-invasive evaluation of knee joint kinematics with weight bearing. This tool may potentially be used for assessing knee kinematics in patients with knee pathology.

Biomechanical Phenomena↗

A new computational efficient approach for trabecular bone analysis using beam models generated with skeletonized graph technique.

Micro-finite element (FE) analysis is a well established technique for the evaluation of the elastic properties of trabecular bone, but is limited in its application due to the large number of elements that it requires to represent the complex internal structure of the bone. In this paper, we present an alternative FE approach that makes use of a recently developed 3D-Line Skeleton Graph Analysis (LSGA) technique to represent the complex internal structure of trabecular bone as a network of simple straight beam elements in which the beams are assigned geometrical properties of the trabeculae that they represent. Since an enormous reduction of cputime can be obtained with this beam modeling approach, ranging from approximately 1,200 to 3,600 for the problems investigated here, we think that the FE modeling technique that we introduced could potentially constitute an interesting alternative for the evaluation of the elastic mechanical properties of trabecular bone.

Algorithms↗

Magnetic resonance imaging of patellofemoral kinematics with weight-bearing.

BACKGROUND: Previous studies of the patellofemoral joint have been limited by the use of invasive techniques, measurements under non-weight-bearing conditions, cadaveric specimens, or computerized models. It has been shown that soft tissue and bone can be accurately quantified with magnetic resonance imaging. The present study was designed to define the relationship between the patellofemoral contact area and patellofemoral kinematics in vivo. METHODS: Ten subjects with clinically normal knee joints were scanned with high-resolution magnetic resonance imaging while they pushed a constant weight (133 N) on the foot-plate of a custom-designed load-bearing apparatus. Images were obtained at five positions of flexion between -10 degrees and 60 degrees. Three-dimensional reconstructions were used to measure the patellofemoral cartilage contact area, patellar centroid, patellar medial and inferior translation, patellar medial and inferior tilt, and patellar varus-valgus rotation. All translation and area measurements were normalized on the basis of the interepicondylar distance. Random-effects models of quadratic regressions were used to evaluate the data. RESULTS: The mean contact area ranged from 126 mm(2) in extension to 560 mm(2) at 60 degrees of flexion. The patella translated inferiorly to a maximum distance of 34 mm at 60 degrees of flexion and translated medially to a maximum distance of 3.2 mm at 30 degrees of flexion before returning to nearly 0 mm at 60 degrees of flexion. The patella tilted inferiorly to a mean of nearly 35 degrees at 60 degrees of flexion and medially to a maximum of 4.2 degrees at 30 degrees of flexion. By 60 degrees of flexion, the centroid of the contact area had shifted to an inferior and posterior maximum of 20 and 10 mm, respectively. CONCLUSIONS: We found that lateral patellar subluxation and tilt occurred in these normal knees at full extension and the patella was reduced into the trochlear groove at 30 degrees of flexion. Therefore, we believe that lateral patellar tilt and subluxation observed during arthroscopy of the extended knee may not represent a pathological condition.

Adult↗