PubMed Health⌕ Search

Biomedical subjects

Eunice Yeoh

Publications and source records attributed to Eunice Yeoh.

3 recordsLinked to original sources

Redefining the normal angiogram using population-derived ranges for coronary size and shape: validation using intravascular ultrasound and applications in diverse patient cohorts.

OBJECTIVES: To develop a method for quantitating coronary angiographic abnormalities of segmental size and shape (tapering) in comparison to gender- and segment-specific, population derived, normal values. BACKGROUND: In the absence of obvious focal stenoses, remodeling renders the angiogram insensitive to the presence of atherosclerosis and invalidates use of a "normal reference segment" for calculation of percent diameter stenosis. METHODS: Equations were created for detection of size/shape abnormalities of coronary angiographic segments. After validation using intravascular ultrasound (IVUS), the equations were applied to a cohort of segments judged to be completely normal by a panel of highly experienced, core laboratory technicians; and a cohort of patients judged by an experienced interventionalist to have completely normal coronaries. RESULTS: In patients assessed by core technicians, 53% (162/303) of males, 39% (209/538) of normal segments in males, 60% (56/94) of females, and 40% (81/205) of normal segments in females had quantifiable abnormalities. In patients with normal coronaries as judged by an experienced interventionalist, 100% of males (n = 14) and females (n = 19), 37% (67/182) of segments in males and 43% (105/247) of segments in females had abnormalities. The left main segment was most commonly abnormal. CONCLUSIONS: We propose a set of equations validated using IVUS and based on gender- and segment-specific normal values for coronary angiographic size and shape that markedly improves the sensitivity of the coronary angiogram for detection of abnormalities. The method should replace the unfounded practice of labeling coronary angiograms as "normal" based solely on the failure to detect focal stenoses.

Cohort Studies↗

Validation of a new ultrasound method for the measurement of carotid artery intima medial thickness and plaque dimensions.

BACKGROUND: Carotid ultrasound is an accepted method for the detection of subclinical atherosclerosis. Valid methods that allow quantitation of carotid atheroma burden may be useful for stratifying risk. OBJECTIVE: To validate the results of intima medial thickness (IMT) and plaque measurements using a newly created software algorithm by comparing them with those obtained using a previously validated method. METHODS: Carotid ultrasound videotapes (n=24) were analyzed by experienced observers using a validated method and a new method. Ultrasound parameters were compared by measuring the difference +/- SD to yield indexes of accuracy and precision. Performance was also assessed using correlation and Bland-Altman analyses. RESULTS: Average IMT (n=24), plaque area (n=46), and several indexes that integrate IMT and plaque measurements were all found to be comparable with measurements obtained using the previously validated method. For example, the plaque area showed excellent accuracy and precision (-0.17+/-2.0 mm2, P=0.56), excellent correlation (r=0.98, standard error of the estimate = 2.01 mm2, P<0.001) and no evidence of bias using Bland-Altman analyses (Spearman's rho = 0.04, P=0.82). CONCLUSIONS: A new algorithm for the quantitation of carotid atheroma burden yields results that are comparable with those of a previously validated and widely used method. Availability of valid tools for measuring carotid ultrasound should facilitate the incorporation of this procedure into clinical risk stratification paradigms.

British Columbia↗

Validation of an automated method for assessing brachial artery endothelial dysfunction.

BACKGROUND: Endothelial dysfunction is an early finding in diverse vascular diseases and can be measured noninvasively using brachial ultrasound. There is great interest in the potential use of this parameter for assessing interventions or cardiovascular prognosis. Automated image analysis of the ultrasound images would facilitate implementation of such measurements in high throughput clinics and/or large clinical trials. OBJECTIVES: To compare a new method designed to assess brachial artery diameter and percentage diameter changes through automated, beat-by-beat image processing (Brachial Tools, Medical Imaging Applications, USA), with a nonautomated method (Prosound System, Jet Propulsion Laboratory, USA). PATIENTS AND METHODS: Brachial ultrasound tapes from 12 patients undergoing endothelial function assessment using forearm cuff-occlusion, measurement of flow-mediated dilation and responses to nitroglycerin were analyzed by both methods. RESULTS: The correlation between the two systems was excellent for both the measurement of absolute diameters (r=0.995, P<0.001) and percentage diameter changes (r=0.973, P<0.001). The automated method demonstrated no bias compared with the frame-by-frame method and excellent precision (0.07 mm and 1.62 percentage diameter change). CONCLUSIONS: The automated method provides valid data while substantially diminishing analysis time.

Adult↗