Evaluation of MLC leaf positioning using a scanning liquid ionization chamber EPID.

A method was developed to determine the accuracy of multileaf collimator (MLC) positioning using transmitted dose maps measured by a scanning liquid ionization chamber electronic portal imaging device (SLIC-EPID). Several MLC fields were designed, using the Varian C-series standard MLC-80, as reference fields for open fields. The MLC leaves were then shifted from the reference positions along the direction of MLC leaf movement towards the central axis from 0.1 to 1.6 mm. The electronic portal images (EPIs), acquired for each case, were converted to two-dimensional dose maps using an appropriate calibration method and the relative dose difference maps were then calculated. The experiment was then performed at non-zero gantry angles in the presence of an anthropomorphic phantom for typical prostate and head and neck fields. Several standard edge detection algorithms were also used in order to find the shifted MLC leaf position. In addition, the short-term reproducibility of MLC leaf positioning was evaluated using the above-mentioned methods. It was found that the relationship between the relative dose difference and MLC leaf spatial displacement is linear. A variation of 0.2 mm in leaf position leads to approximately 4% change in the relative dose values for open fields. The variation of the relative dose difference for phantom studies depends on the phantom positioning and the EPI normalization. From the standard edge detection algorithms, used in the current study, the 'Canny' algorithm was found to be the optimum method to identify the minimum detectable MLC leaf displacements with a precision of approximately 0.1 mm for all cases. However, the result of edge detection algorithms generally is binary and there is no additional information compared to the relative dose maps. The reproducibility of MLC positions was found to be within 0.3 mm. In conclusion, a SLIC-EPID can be used for regular quality assurance (QA) of MLC leaf positioning. Despite significant difference in the pixel size of the acquired SLIC-EPIs, it can be concluded that the SLIC-EPID can be used for MLC quality assurance protocols with similar accuracy compared to amorphous silicon (a-Si) EPID results.

Algorithms↗

Two-dimensional transmitted dose measurements using a scanning liquid ionization chamber EPID.

The use of a scanning liquid ionization chamber electronic portal imaging device (SLIC-EPID) for two-dimensional transmitted dosimetry was investigated and a calibration method was developed using extended dose range (EDR2) film. In order to convert pixel value to dose, the acquired SLIC-EPID pixel values were calibrated using an ionization chamber on the central axis. The relationship between pixel values, dose rate and absorbed dose was identified for various linac output repetition rates. To correct EPIs for dosimetric purposes, the off-axis ratio of dose profiles measured by EPIDs and EDR2 film was used to derive correction factor matrices (CFMs) for a range of source-to-EPID distances (SEDs). The corrected relative dose maps acquired for different conditions, including open and wedged fields, measured using a SLIC-EPID were compared with EDR2 film images using a gamma function algorithm with distance to agreement (DTA) = 2.5 mm and dose difference (DeltaDmax) = 1% criteria. The results showed that (a) for two-dimensional dosimetric purposes, EPIDs must be calibrated using appropriate two-dimensional correction factors and (b) SLIC-EPIDs can be used to measure the transmitted dose with good accuracy.

Algorithms↗

2D versus 3D radiation therapy for prostate carcinoma: a direct comparison of dose volume parameters.

That three dimensional (3D) planning for radiation therapy (RT) of carcinoma of the prostate (CaP) improves radiation dosimetry to the tumour and reduces dose to the rectum and bladder compared with 2D planning, has not been properly evaluated. We addressed this by downloading the CT data files of twenty-two patients who had completed 2D planned RT for CaP onto a 3D planning system and re-planning RT using the same four field technique and dose prescription as the 2D technique. The radiation dose at 100%, 90%, 50% and 0% volumes (D100, D90, D50 and D0) of the Dose Volume Histograms (DVH's) of the GTV, PTV, rectum and bladder, the area under the curves of each DVH and the field sizes were evaluated and compared between the two sets of plans. Repeated measured t-tests were used to compare the means of the different measurements. The D100, D90 and D50 of the GTV, PTV and rectum were increased for the 3D versus the 2D plans (p < 0.05 for each parameter). The area under the rectal DVH was also greater for the 3D plans (p < 0.05). These changes are attributable to the larger field sizes, particularly the length in the 3D compared with the 2D plans.

Aged↗