PubMed Health⌕ Search

Biomedical subjects

Eva Maria Fallenberg

Publications and source records attributed to Eva Maria Fallenberg.

5 recordsLinked to original sources

Assessment of coronary artery stents using 16-slice MDCT angiography: evaluation of a dedicated reconstruction kernel and a noise reduction filter.

To compare the effect of different reconstruction kernels and a noise-reducing postprocessing filter on the delineation of coronary artery stents in 16-slice CT-angiography. Ten patients with coronary stents (seven LAD, five RCX and three RCA) were examined with a 16-slice MDCT using standard acquisition parameters. Images were reconstructed using a medium soft (B30f) and a dedicated, edge-enhancing kernel (B46f). Additional postprocessing with an edge-preserving filter was performed on B46f images to reduce the image noise. In multiplanar reformations (MPRs) along and perpendicular to the stent axis, intraluminal attenuation values and the visible lumen diameter were measured. Image noise was measured in the subcutaneous fat using a region of interest (ROI) technique. Arterial enhancement in the aorta was 275.1 HU. Attenuation in the stent lumen was 390.4, 340.0 and 346.8 HU in MPRs derived from B30f, original B46 and postprocessed B46f images. The mean noise level was 20.4, 35.0 and 24.9 HU respectively. The visible lumen diameter was significantly greater in B46f and postprocessed B46f images (2.17 and 2.16 mm), compared to 1.93 mm in B30f images (p<0.01). Edge-enhancing reconstruction kernels increase the visible stent lumen, but also increase image noise. Dedicated postprocessing filters can reduce the introduced noise without a loss of spatial resolution.

Artifacts↗

Multi-detector row computed tomography of the heart: does a multi-segment reconstruction algorithm improve left ventricular volume measurements?

A multi-segment cardiac image reconstruction algorithm in multi-detector row computed tomography (MDCT) was evaluated regarding temporal resolution and determination of left ventricular (LV) volumes and global LV function. MDCT and cine magnetic resonance (CMR) imaging were performed in 12 patients with known or suspected coronary artery disease. Patients gave informed written consent for the MDCT and the CMR exam. MDCT data were reconstructed using the standard adaptive cardiac volume (ACV) algorithm as well as a multi-segment algorithm utilizing data from three, five and seven rotations. LV end-diastolic (LV-EDV) and end-systolic volumes and ejection fraction (LV-EF) were determined from short-axis image reformations and compared to CMR data. Mean temporal resolution achieved was 192+/-24 ms using the ACV algorithm and improved significantly utilizing the three, five and seven data segments to 139+/-12, 113+/-13 and 96+/-11 ms (P<0.001 for each). Mean LV-EDV was without significant differences using the ACV algorithm, the multi-segment approach and CMR imaging. Despite improved temporal resolution with multi-segment image reconstruction, end-systolic volumes were less accurately measured (mean differences 3.9+/-11.8 ml to 8.1+/-13.9 ml), resulting in a consistent underestimation of LV-EF by 2.3-5.4% in comparison to CMR imaging (Bland-Altman analysis). Multi-segment image reconstruction improves temporal resolution compared to the standard ACV algorithm, but this does not result in a benefit for determination of LV volume and function.

Adult↗

Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

PURPOSE: To determine left ventricular (LV) volumetric and functional parameters from retrospectively electrocardiographically gated multi-detector row computed tomography (CT) by using semiautomated analysis software and to correlate results with those of magnetic resonance (MR) imaging. MATERIALS AND METHODS: In 30 patients (mean age, 59.2 years +/- 7.1 [SD]) known to have or suspected of having coronary artery disease, four-channel multi-detector row CT was performed with standard technique, and diastolic and systolic image reconstructions were generated. With commercially available analysis software capable of semiautomated contour detection, end diastolic and end systolic LV volumes were determined from short-axis secondary CT reformations. Steady-state free-precession cine MR images were acquired in short-axis orientation within 48 hours and analyzed by using dedicated software. Bland-Altman analysis was performed to calculate limits of agreement and systematic errors between CT and MR imaging. RESULTS: Mean end diastolic (138.8 mL +/- 31.9) and end systolic (53.9 mL +/- 21.2) LV volumes as determined with CT correlated well with MR imaging measurements (142.0 mL +/- 32.5 [r = 0.93] and 54.9 mL +/- 22.8 [r = 0.94], respectively [P <.001]). LV ejection fraction (61.6% +/- 10.6 for CT vs 62.3% +/- 10.1 for MR imaging; r = 0.89) and stroke volume (84.6 mL +/- 20.9 for CT vs 86.9 mL +/- 21.5 for MR imaging; r = 0.88) also showed good correlation (P <.001). Bland-Altman analysis showed acceptable limits of agreement (+/-9.8% for ejection fraction) without systematic errors. CONCLUSION: In selected patients, semiautomated analysis software enables LV volumetric and functional analysis based on multi-detector row CT data sets, the results of which correlate well with MR imaging findings.

Aged↗

Evaluation of global left ventricular myocardial function with electrocardiogram-gated multidetector computed tomography: comparison with magnetic resonance imaging.

RATIONALE AND OBJECTIVES: Electrocardiogram-gated 3D volume data from multidetector computed tomography coronary angiography (MDCT-CA) enable image reconstruction in any phase of the cardiac cycle. The objective was to determine left ventricular (LV) function parameters by MDCT in comparison to cine magnetic resonance imaging (MRI). METHOD: Thirty patients with known or suspected coronary artery disease (CAD) underwent MDCT-CA. From multiplanar reformations in short axis orientation end-diastolic and end-systolic LV volumes (LVEDV, LVESV) were determined to calculate LV stroke volume and ejection fraction (LVSV, LVEF) and compared with MRI measurements. RESULTS: LVEDV (147 +/- 27 mL) and LVESV (65 +/- 22 mL) determined by MDCT correlated well to the respective MRI measurements (LVEDV 133 +/- 27 mL, r = 0.80, P < 0.001; LVESV 48 +/- 19 mL, r = 0.89, P < 0.001). LVSV (MDCT 82 +/- 15 mL; MRI 85 +/- 17 mL; r = 0.77, P < 0.001) and LVEF (MDCT 56 +/- 9%; MRI 65 +/- 8%; r = 0.85, P < 0.001) showed a good correlation as well. LVEF was significantly underestimated by MDCT (-8.5 +/- 4.7%, P < 0.001). CONCLUSIONS: Initial experience in patients evaluated for CAD shows that spiral MDCT studies may provide LV functional data in good correlation to Cine MRI.

Adult↗

Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease.

OBJECTIVE: Retrospectively ECG-gated three-dimensional volume data from multidetector CT (MDCT) coronary angiography enable image reconstruction of the cardiac cycle in the diastolic and systolic phases. The objective of our study was to investigate the feasibility of determining left ventricular function from MDCT coronary angiography data sets in 22 patients with coronary artery disease and to study the correlation of MDCT results with those of functional data from biplane cineventriculography. CONCLUSION: Multiplanar reformations from three-dimensional MDCT data allowed good delineation of endocardial and epicardial left ventricular contours. In patients evaluated for coronary artery disease, MDCT coronary angiography with retrospective ECG gating provides functional data in an acceptable correlation (r = 0.8; p < 0.05) to biplane cineventriculography.

Adult↗