PubMed Health⌕ Search

Biomedical subjects

Eve Langelier

Publications and source records attributed to Eve Langelier.

3 recordsLinked to original sources

Cross-sectional profiles and volume reconstructions of soft tissues using laser beam measurements.

Precise geometric reconstruction is a valuable tool in the study of soft tissues biomechanics. Optical methods have been developed to determine the tissue cross section without mechanical contact with the specimen. An adaptation of the laser micrometer developed by Lee and Woo [ASME J. Biomech. Eng., 110 (2), pp. 110-114]. is proposed in which the laser-collimated beam rotates around and moves along a fixed specimen to reconstruct its cross sections and volume. Beam motion is computer controlled to accelerate data acquisition and improve beam positioning accuracy. It minimizes time-dependent shape modifications and increases global reconstruction precision. The technique is also competent for the measurement of immersed collagen matrices.

Algorithms↗

Increasing strain and strain rate strengthen transient stiffness but weaken the response to subsequent compression for articular cartilage in unconfined compression.

Strain amplitude and strain rate dependent nonlinear behavior and load-induced mechanical property alterations of full-thickness bovine articular cartilage attached to bone were investigated in unconfined compression. A sequence of test compressions of finite deformation (ranging from 0.9% to 34.5% nominal strain) was performed at strain rates ranging from approximately 0.053%/s to 5.8%/s. Peak and equilibrium loads were analyzed to determine strain amplitude and strain rate dependence of linear versus nonlinear responses. The test protocol was designed to reveal changes in mechanical properties due to these finite deformations by interspersing small-amplitude witness ramps of approximately 1.1% deformation and approximately 0.44%/s strain rate between the test ramps ("witness" meaning to assess any mechanical property changes). We found that peak loads displayed high nonlinearity, stiffening with both increasing compression amplitude and more so with increasing strain rate. The response to witness ramps suggested that mechanical weakening occurred when compression amplitude reached 1.9-2.9% strain and beyond, and that weakening was much more significant at higher strain rate. These findings delineate regimes of linear versus nonlinear behavior of cartilage, and indicate the types of loads which can cause mechanical property alterations. Biological implications of this study are that strain amplitude and strain rate dependent stiffening may be essential to bear physiological loads and to protect cells and matrix from mechanical damage. Structural changes reflected by mechanical weakening at small compression could also initiate remodeling or disease processes.

Animals↗

Tissue reorganization in response to mechanical load increases functionality.

In the rapidly growing field of tissue engineering, the functional properties of tissue substitutes are recognized as being of the utmost importance. The present study was designed to evaluate the effects of static mechanical forces on the functionality of the produced tissue constructs. Living tissue sheets reconstructed by the self-assembly approach from human cells, without the addition of synthetic material or extracellular matrix (ECM), were subjected to mechanical load to induce cell and ECM alignment. In addition, the effects of alignment on the function of substitutes reconstructed from these living tissue sheets were evaluated. Our results show that tissue constructs made from living tissue sheets, in which fibroblasts and ECM were aligned, presented higher mechanical resistance. This was assessed by the modulus of elasticity and ultimate strength as compared with tissue constructs in which components were randomly oriented. Moreover, tissue-engineered vascular media made from a prealigned living tissue sheet, produced with smooth muscle cells, possessed greater contractile capacity compared with those produced from living tissue sheets that were not prealigned. These results show that the mechanical force generated by cells during tissue organization is an asset for tissue component alignment. Therefore, this work demonstrates a means to improve the functionality (mechanical and vasocontractile properties) of tissues reconstructed by tissue engineering by taking advantage of the biomechanical forces generated by cells under static strain.

Biocompatible Materials↗