PubMed Health⌕ Search

Biomedical subjects

Evonne T Curran

Publications and source records attributed to Evonne T Curran.

2 recordsLinked to original sources

Controlling methicillin-resistant Staphylococcus aureus: a feedback approach using annotated statistical process control charts.

OBJECTIVES: To investigate the benefit of a hospitalwide feedback program regarding methicillin-resistant Staphylococcus aureus (MRSA), using annotated statistical process control charts. DESIGN: Retrospective and prospective analysis of MRSA rates using statistical process control charts. PARTICIPANTS: Twenty-four medical, medical specialty, surgical, intensive care, and cardiothoracic care wards and units at four Glasgow Royal Infirmary hospitals. METHODS: Annotated control charts were applied to prospective and historical monthly data on MRSA cases from each ward and unit during a 46-month period from January 1997 through September 2000. Results were fed back from December 1999 and then on a regular monthly basis to medical staff, ward managers, senior managers, and hotel services. RESULTS: Monthly reductions in the MRSA acquisition rate started 2 months after the introduction of the feedback program and have continued to the present time. The overall MRSA rate currently is approximately 50% lower than when the program began and has become more consistent and less variable within departments throughout Glasgow Royal Infirmary. The control charts have helped to detect rate changes and manage resources more effectively. Medical and nursing staff and managers also report that they find this the most positive form of MRSA feedback they have received. CONCLUSIONS: Feedback programs that provide current information to front-line staff and incorporate annotated control charts can be effective in reducing the rate of MRSA.

Humans↗

Decontamination of reusable instruments in primary care.

Staff who undertake effective decontamination in non-centralized settings such as general practices must be provided with training and easy-to-follow guidance. In this article we present a distillation of the current guidance in an industrial quality control format of fishbone charts. A fishbone chart (or cause-and-effect chart) depicts all the causes of an outcome in a logical way to facilitate the identification of a specific problem. We developed our fishbone chart to include instructions that, if followed, would achieve safe and effective cleaning and sterilization. A survey of those given the charts showed high user acceptability: 76% found the fishbone better than existing guidelines - although the response rate was low at 46%. The charts will enable those involved in decontamination of instruments, including managers and infection control staff, to audit the facilities, equipment and practices. The use of industrial quality tools may assist other specialties that require complicated and comprehensive guidelines to be presented in a more user-friendly design.

Cross Infection↗