Publications and source records attributed to Ewert Bengtsson.

9 recordsLinked to original sources

A new application of pre-normalized principal component analysis for improvement of image quality and clinical diagnosis in human brain PET studies--clinical brain studies using [11C]-GR205171, [11C]-L-deuterium-deprenyl, [11C]-5-Hydroxy-L-Tryptophan, [11C]-L-DOPA and Pittsburgh Compound-B.

Principal component analysis (PCA) is one of the most applied multivariate image analysis tool on dynamic Positron Emission Tomography (PET). Independent of used reconstruction methodologies, PET images contain correlation in-between pixels, correlations in-between frame and errors caused by the reconstruction algorithm including different corrections, which can affect the performance of the PCA. In this study, we have investigated a new approach of application of PCA on pre-normalized, dynamic human PET images. A range of different tracers have been used for this purpose to explore the performance of the new method as a way to improve detection and visualization of significant changes in tracer kinetics and to enhance the discrimination between pathological and healthy regions in the brain. We compare the new results with the results obtained using other methods. Images generated using the new approach contain more detailed anatomical information with higher quality, precision and visualization, compared with images generated using other methods.

Antiemetics↗

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM.

BACKGROUND: Positron Emission Tomography (PET), Computed Tomography (CT), PET/CT and Single Photon Emission Tomography (SPECT) are non-invasive imaging tools used for creating two dimensional (2D) cross section images of three dimensional (3D) objects. PET and SPECT have the potential of providing functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules, whereas CT visualizes X-ray density in tissues in the body. PET/CT provides fused images representing both functional and anatomical information with better precision in localization than PET alone. Images generated by these types of techniques are generally noisy, thereby impairing the imaging potential and affecting the precision in quantitative values derived from the images. It is crucial to explore and understand the properties of noise in these imaging techniques. Here we used autocorrelation function (ACF) specifically to describe noise correlation and its non-isotropic behaviour in experimentally generated images of PET, CT, PET/CT and SPECT. METHODS: Experiments were performed using phantoms with different shapes. In PET and PET/CT studies, data were acquired in 2D acquisition mode and reconstructed by both analytical filter back projection (FBP) and iterative, ordered subsets expectation maximisation (OSEM) methods. In the PET/CT studies, different magnitudes of X-ray dose in the transmission were employed by using different mA settings for the X-ray tube. In the CT studies, data were acquired using different slice thickness with and without applied dose reduction function and the images were reconstructed by FBP. SPECT studies were performed in 2D, reconstructed using FBP and OSEM, using post 3D filtering. ACF images were generated from the primary images, and profiles across the ACF images were used to describe the noise correlation in different directions. The variance of noise across the images was visualised as images and with profiles across these images. RESULTS: The most important finding was that the pattern of noise correlation is rotation symmetric or isotropic, independent of object shape in PET and PET/CT images reconstructed using the iterative method. This is, however, not the case in FBP images when the shape of phantom is not circular. Also CT images reconstructed using FBP show the same non-isotropic pattern independent of slice thickness and utilization of care dose function. SPECT images show an isotropic correlation of the noise independent of object shape or applied reconstruction algorithm. Noise in PET/CT images was identical independent of the applied X-ray dose in the transmission part (CT), indicating that the noise from transmission with the applied doses does not propagate into the PET images showing that the noise from the emission part is dominant. The results indicate that in human studies it is possible to utilize a low dose in transmission part while maintaining the noise behaviour and the quality of the images. CONCLUSION: The combined effect of noise correlation for asymmetric objects and a varying noise variance across the image field significantly complicates the interpretation of the images when statistical methods are used, such as with statistical estimates of precision in average values, use of statistical parametric mapping methods and principal component analysis. Hence it is recommended that iterative reconstruction methods are used for such applications. However, it is possible to calculate the noise analytically in images reconstructed by FBP, while it is not possible to do the same calculation in images reconstructed by iterative methods. Therefore for performing statistical methods of analysis which depend on knowing the noise, FBP would be preferred.

Journal Article↗

Non-isotropic noise correlation in PET data reconstructed by FBP but not by OSEM demonstrated using auto-correlation function.

BACKGROUND: Positron emission tomography (PET) is a powerful imaging technique with the potential of obtaining functional or biochemical information by measuring distribution and kinetics of radiolabelled molecules in a biological system, both in vitro and in vivo. PET images can be used directly or after kinetic modelling to extract quantitative values of a desired physiological, biochemical or pharmacological entity. Because such images are generally noisy, it is essential to understand how noise affects the derived quantitative values. A pre-requisite for this understanding is that the properties of noise such as variance (magnitude) and texture (correlation) are known. METHODS: In this paper we explored the pattern of noise correlation in experimentally generated PET images, with emphasis on the angular dependence of correlation, using the autocorrelation function (ACF). Experimental PET data were acquired in 2D and 3D acquisition mode and reconstructed by analytical filtered back projection (FBP) and iterative ordered subsets expectation maximisation (OSEM) methods. The 3D data was rebinned to a 2D dataset using FOurier REbinning (FORE) followed by 2D reconstruction using either FBP or OSEM. In synthetic images we compared the ACF results with those from covariance matrix. The results were illustrated as 1D profiles and also visualized as 2D ACF images. RESULTS: We found that the autocorrelation images from PET data obtained after FBP were not fully rotationally symmetric or isotropic if the object deviated from a uniform cylindrical radioactivity distribution. In contrast, similar autocorrelation images obtained after OSEM reconstruction were isotropic even when the phantom was not circular. Simulations indicated that the noise autocorrelation is non-isotropic in images created by FBP when the level of noise in projections is angularly variable. Comparison between 1D cross profiles on autocorrelation images obtained by FBP reconstruction and covariance matrices produced almost identical results in a simulation study. CONCLUSION: With asymmetric radioactivity distribution in PET, reconstruction using FBP, in contrast to OSEM, generates images in which the noise correlation is non-isotropic when the noise magnitude is angular dependent, such as in objects with asymmetric radioactivity distribution. In this respect, iterative reconstruction is superior since it creates isotropic noise correlations in the images.

Journal Article↗

Image analysis for automatic segmentation of cytoplasms and classification of Rac1 activation.

BACKGROUND: Rac1 is a GTP-binding molecule involved in a wide range of cellular processes. Using digital image analysis, agonist-induced translocation of green fluorescent protein (GFP) Rac1 to the cellular membrane can be estimated quantitatively for individual cells. METHODS: A fully automatic image analysis method for cell segmentation, feature extraction, and classification of cells according to their activation, i.e., GFP-Rac1 translocation and ruffle formation at stimuli, is described. Based on training data produced by visual annotation of four image series, a statistical classifier was created. RESULTS: The results of the automatic classification were compared with results from visual inspection of the same time sequences. The automatic classification differed from the visual classification at about the same level as visual classifications performed by two different skilled professionals differed from each other. Classification of a second image set, consisting of seven image series with different concentrations of agonist, showed that the classifier could detect an increased proportion of activated cells at increased agonist concentration. CONCLUSIONS: Intracellular activities, such as ruffle formation, can be quantified by fully automatic image analysis, with an accuracy comparable to that achieved by visual inspection. This analysis can be done at a speed of hundreds of cells per second and without the subjectivity introduced by manual judgments.

Animals↗

Abnormal expression pattern of cyclin E in tumour cells.

The expression pattern of cyclin E during the cell cycle was studied in normal and tumour cells in culture and in tumour biopsies. This pattern was found to be abnormal in tumour cells. A triple immunostaining protocol, digital microscopy and image analysis were used to find the position of the individual cells in the cell cycle and to measure the nuclear cyclin E levels. In normal cells, the number of cyclin E-positive cells decreased rapidly when the cells entered the S-phase. In the tumour cell lines, cyclin E was not downregulated in early S-phase, as in normal cells. Instead the number of cyclin E-positive cells remained high throughout S-phase, and the cyclin E staining intensity per cell often increased during S-phase. In about half of the analysed tumour cell lines, many cells stained positive for cyclin E even in the G(2)-phase. This abnormal expression over the cell cycle of cyclin E was also found in tumour biopsies from cervical, breast and prostatic carcinomas, even though it varied greatly between individual tumours. In some tumours, the expression pattern of cyclin E was similar to that of normal cells in culture, whereas in others high cyclin E levels could be seen in S-phase cells, as in the transformed cell lines. A high percentage of cells expressing cyclin E during S- or G(2)-phase was found to be related to poor outcome (p < 0.025) in a small group of cervical carcinoma patients (n = 12).

Biomarkers, Tumor↗

A feature set for cytometry on digitized microscopic images.

Feature extraction is a crucial step in most cytometry studies. In this paper a systematic approach to feature extraction is presented. The feature sets that have been developed and used for quantitative cytology at the Laboratory for Biomedical Image Analysis of the GSF as well as at the Center for Image Analysis in Uppsala over the last 25 years are described and illustrated. The feature sets described are divided into morphometric, densitometric, textural and structural features. The latter group is used to describe the eu- and hetero-chromatin in a way complementing the textural methods. The main goal of the paper is to bring attention to the need of a common and well defined description of features used in cyto- and histometrical studies. The application of the sets of features is shown in an overview of projects from different fields. Finally some rules of thumb for the design of studies in this field are proposed. Colour figures can be viewed on http://www.esacp.org/acp/2003/25-1/rodenacker.htm.

Algorithms↗

Sequential immunofluorescence staining and image analysis for detection of large numbers of antigens in individual cell nuclei.

BACKGROUND: Visualization of more than one antigen by multicolor immunostaining is often desirable or even necessary to explore spatial and temporal relationships of functional significance. Previously presented staining protocols have been limited to the visualization of three or four antigens. METHODS: Immunofluorescence staining was performed both on slices of formalin-fixed tissue and on cells in culture. Images of the stained material were recorded using digital imaging fluorescence microscopy. The primary and secondary antibodies, as well as the fluorophores, were thereafter removed using a combination of denaturation and elution techniques. After removal of the fluorescence stain, a new immunofluorescence staining was performed, visualizing a new set of antigens. The procedure was repeated up to three times. A method for image registration combined with segmentation, extraction of data, and cell classification was developed for efficient and objective analysis of the image data. RESULTS: The results show that immunofluorescence stains in many cases can be repeatedly removed without major effects on the antigenicity of the sample. CONCLUSIONS: The concentration of at least six different antigens in each cell can thus be measured semiquantitatively using sequential immunofluorescence staining and the described image analysis techniques. The number of antigens that can be visualized in a single sample is considerably increased by the presented protocol.

Antibodies↗

Algorithms for cytoplasm segmentation of fluorescence labelled cells.

Automatic cell segmentation has various applications in cytometry, and while the nucleus is often very distinct and easy to identify, the cytoplasm provides a lot more challenge. A new combination of image analysis algorithms for segmentation of cells imaged by fluorescence microscopy is presented. The algorithm consists of an image pre-processing step, a general segmentation and merging step followed by a segmentation quality measurement. The quality measurement consists of a statistical analysis of a number of shape descriptive features. Objects that have features that differ to that of correctly segmented single cells can be further processed by a splitting step. By statistical analysis we therefore get a feedback system for separation of clustered cells. After the segmentation is completed, the quality of the final segmentation is evaluated. By training the algorithm on a representative set of training images, the algorithm is made fully automatic for subsequent images created under similar conditions. Automatic cytoplasm segmentation was tested on CHO-cells stained with calcein. The fully automatic method showed between 89% and 97% correct segmentation as compared to manual segmentation.

Algorithms↗

Faster shading by equal angle interpolation of vectors.

In this paper, we show how spherical linear interpolation can be used to produce shading with a quality at least similar to Phong shading at a computational effort in the inner loop that is close to that of the Gouraud method. We show how to use the Chebyshev's recurrence relation in order to compute the shading very efficiently. Furthermore, it can also be used to interpolate vectors in such a way that normalization is not necessary, which will make the interpolation very fast. The somewhat larger setup effort required by this approach can be handled through table look up techniques.

Algorithms↗