Publications and source records attributed to F A Arabia.

24 records · Page 2Linked to original sources

Cost analysis of the Novacor Left Ventricular Assist System as an outpatient bridge to heart transplantation.

Three patients were bridged to heart transplantation with the wearable Novacor Left Ventricular Assist System (Baxter Healthcare Corp., Oakland, CA) (LVAS). Two have been transplanted and discharged. The third patient remains at home. Hospitalization costs, which include the unit room charge, admission profile to the unit, and daily supply charge, were determined for all patients and compared. The patients were transferred from the surgical intensive care unit to a telemetry unit once they were hemodynamically stable. The projected hospitalization costs, if the patients had remained in the hospital, were calculated to determine probable savings for the third party payer. The average period from admission to placement of the Novacor LVAS was 15 days (range, 7-21 days). The average hospitalization cost from admission to time of Novacor left ventricular assist device implant was $2,240/day, and the average hospitalization cost after implant to discharge was $1,570/day. Hospitalization cost savings were $2,632 for the first patient, $5,922 for the second patient, and $132,124 for the third patient, who has not been transplanted. Although the number of patients is small, the daily hospitalization cost was higher before the Novacor LVAS was implanted. This is related to the severity of the disease and the length of stay in a surgical intensive care unit. There also is a significant cost savings for the third party payer, especially if the patient has to wait a significant amount of time before heart transplantation. These are important considerations in this time of managed care.

Ambulatory Care↗

Update on the total artificial heart.

There has been a quest for an artificial organ that can replace the heart for decades. Remarkable advances were made in the second half of the twentieth century in the fields of medicine and engineering that led to the development of several devices with the intention of totally replacing the human heart. Some of these devices, like the Jarvik artificial heart, were utilized initially as a permanent replacement for the failing heart. It became more successful as a bridge to heart transplantation (BTT) in the years that followed its introduction. Currently the CardioWest total artificial heart (TAH) is the only device in clinical use with the intention of bridging patients to heart transplantation. Two new TAHs are being developed with the intention of being used as an alternative to transplantation (ATT) or on a permanent basis. The next 100 years will bring revolutionary new designs and advances in the field of end stage heart disease that may only be ideas at the present time.

Heart Transplantation↗

A computerized physiologic pulse duplicator for in-vitro hydrodynamic and ultrasonic studies of prosthetic heart valves.

A physiologic pulse duplicator for the simultaneous in-vitro hydrodynamic and ultrasonic evaluation of aortic prosthetic heart valves is described. The system is interfaced to a personal computer, which provides greater efficiency over manual techniques in system calibration, data acquisition, and analysis. The data analysis program aids selection of start and end systole and calculates pressure difference across the valve, the closing and regurgitant volumes, flow rates, and the Gabbay and Swanson performance indices. The pulse duplicator is designed to accommodate the ultrasonic measurement of fluid velocities, including pressure difference via the Bernoulli equation, and color-flow imaging. In tests of 19-mm, 23-mm, and 27-mm Bjork-Shiley spherical occluder valves, continuous-wave Doppler ultrasound was found to overestimate by about 50% the pressure difference measured directly by pressure transducers, a finding that is clinically important.

Aortic Valve↗

Is it necessary to perform surveillance endomyocardial biopsies in heart transplant recipients?

BACKGROUND: Routine surveillance endomyocardial biopsies to diagnose unsuspected rejection are performed at 3- to 12-month intervals after heart transplantation. From 1979 to 1989, surveillance biopsies were routinely performed as a part of the yearly evaluation. METHODS: A retrospective analysis of the follow-up data showed that "routine surveillance biopsies" had an extremely low yield, and, on the basis of the results of this study, we discontinued to perform surveillance biopsies beyond 6 months after transplantation. To validate these results, we compared the outcome of two groups of patients who had similar demographics and identical immunosuppression, except that in one group the surveillance biopsies were not performed. RESULTS: No difference was found in either actuarial survival rate or freedom from late rejection between the two groups. CONCLUSIONS: These findings confirm that routine surveillance heart biopsies beyond 6 months after transplantation are not necessary and they should be performed only if there is clinical suspicion of rejection or as part of a research protocol.

Actuarial Analysis↗

Correlation of clinical embolic events with coagulability in a patient with a total artificial heart.

A 46-year-old female patient was supported for 185 days with a total artificial heart, underwent successful transplantation, and survived for over 1 year with no clinical residual findings suggestive of embolic events. Daily observation, analysis of a large battery of coagulation tests, and eight serial computed tomographic scans suggest that she had 12 embolic events while receiving mechanical support. Furthermore, it appears that the events were associated temporally with several mild infections and that coagulation was stimulated several days to 1 week before we detected the events.

Blood Coagulation↗