PubMed Health⌕ Search

Biomedical subjects

F A Bassi

Publications and source records attributed to F A Bassi.

10 recordsLinked to original sources

Growth kinetics and structure of fibrin gels.

The structure and kinetics of fibrin gels grown from fibrinogen solutions under quasiphysiological conditions, but in absence of Ca++, were investigated by means of elastic light scattering. By combining classical light scattering and low-angle elastic light scattering, an overall wave-vector range of about three decades was spanned, from q approximately 3 x 10(2) to q approximately 3 x 10(5) cm(-1). The scattered intensity distribution of the gels was measured in absolute units and fitted to a single function, which was able to reproduce accurately the data over the entire wave-vector range. From the fitting, it was possible to estimate the average diameter d of the fibrin fibers, the average crossover length xi of the gel, and establish the fractal nature of the gel structure, with a measure of its fractal dimension D(m). The measure of the intensity in absolute units also allowed the estimate of the density rho of the fibrin fibers and provided an independent measure of their size. The kinetics of formation of the gel was described in terms of a simple growth model: the scaffold of the network is formed very early in the course of the gelation process, at a "networking time," t(n), which is much smaller than the time required to form the final gel. At times t>t(n), the gel structure remains substantially unchanged and the successive growth consists only in a thickening of the gel fibers. Gels prepared under the same physical-chemical conditions, but at different fibrinogen concentrations, exhibited rather similar structures and kinetics, showing that the modalities of the gelation process are mainly governed by the solution conditions, and only secondarily by the fibrinogen concentration. For gels at fibrinogen concentration of approximately 0.24 mg/ml, the gel parameters were d approximately 130 nm, xi approximately 27 microm, D(m) approximately 1.3, and rho approximately 0.4 g/cm(3). Our d and rho values are in very good agreement with electron microscopy- and turbidity-derived literature data, respectively, while xi seems to be related to the mesh size of the initial scaffold formed at t(n), rather than to the mesh size of the final aged gel.

Fibrin↗

Nonlinear tension summation of different combinations of motor units in the anesthetized cat peroneus longus muscle.

The purpose of this study was to examine the linearity of summation of the forces produced by the stimulation of different combinations of type identified motor units (MUs) in the cat peroneus longus muscle (PL) under isometric conditions. The muscle was fixed at its twitch optimal length, and the tension produced by the single MU was recorded during 24- and 72-Hz stimulation. The summation analysis was first carried out for MUs belonging to the same functional group, and then different combinations of fast fatigable (FF) MUs were added to the nonfatigable slow (S) and fatigue resistant (FR) group. The tension resulting from the combined stimulation of increasing numbers of MUs (measured tension) was evaluated and compared with the linearly predicted value, calculated by adding algebraically the tension produced by the individual MUs assembled in the combination (calculated tension). Tension summation displayed deviations from linearity. S and FR MUs mainly showed marked more than linear summation; FF MUs yielded either more or less than linear summation; and, when the FF units were recruited after the S and FR MUs, less than linear summation always occurred. The magnitude of the nonlinear summation appeared stimulus frequency dependent for the fatigable FF and FI group. The relationship between measured tension and calculated tension for each MU combination was examined, and linear regression lines were fitted to each set of data. The high correlation coefficients and the different slope values for the different MU-type combinations suggested that the nonlinear summation was MU-type specific. The mechanisms of nonlinear summations are discussed by considering the consequences of internal shortening and thus the mechanical interactions among MUs and shifts in muscle fiber length to a more or less advantageous portion of single MU length-tension curves.

Anesthesia↗

Dynamic light scattering study of fine semiflexible fibrin networks.

Fine fibrin networks have been investigated using the dynamic light scattering (DLS) technique. At the shortest delay times, t, the dynamic structure factor s(q,t) is found to depend on time according to an exponential function and, at intermediate delay times (up to 1 ms), to a stretched exponential. At longer times (t > 1 ms), a progressively increasing deviation from the stretched exponential behaviour has been observed. These results are in agreement with the theoretical predictions of a recently forwarded model for semiflexible polymers in semidilute solutions [K. Kroy and E. Frey, Physical Review E 55 (1996) p. 3092.], despite the fact that fibrin networks are made up of crosslinked branched polymers. The model, moreover, allows the calculation from the initial decay rate gamma q(0) of the average diameter of the fibrin fibres, a. The value of a = 30 +/- 2 nm, at fibrinogen concentration c(f) = 1676 nM and ionic strength 0.5, fits well into the data reported in electron microscopy studies. A concentration dependence of the average diameter of the fibrin fibres has been observed which saturates at the highest concentrations. The diameter of fibrin fibres is an important component in determining the physical properties of the fibrin networks, since the radial growth of fibrin fibres is limited by twisting during protofibrils aggregation. Our results indicate the importance of taking into account intrinsic semiflexibility in studying the physical properties of 'real' polymers and emphasize the high sensitivity of the DLS technique to investigate biological polymers also at the lowest concentrations where the systems are very fragile.

Buffers↗

Peptide mapping through the coupling of capillary electrophoresis and high-performance liquid chromatography: map prediction of the tryptic digest of myoglobin.

The tryptic map of horse myoglobin was analysed through capillary electrophoresis using capillaries modified by a monolayer of acrylamide. The results were reproducible and the map was obtained in less than 30 min from ca. 8 pmol of tryptic digest. The peptide identification was performed using peptides previously identified by high-performance liquid chromatography. The peak areas measured using the two techniques are closely related, and the comparison of elution and migration times shows that the two techniques provide different maps. Furthermore, using the semiempirical relationship suggested by Grossman et al. [Anal. Biochem., 179 (1989) 28], which links the electrophoretic mobility to the charge of the peptide and its number of amino acids, a good agreement between predicted and experimental mobilities was observed.

Amino Acids↗

Point perturbation analysis of experimental data: II. The statistics of relaxation length values of pseudo-random errors.

The statistics of relaxation lengths for pseudo-random deviates as determined by point perturbation analysis (E. Di Cera, F. Andreasi Bassi and G. Arcovito Biophys. Chem. 34 (1989)239),has been constructed by a Monte Carlo study. The values of the relaxation length, L, approximately follow a Gamma distribution. The results allow for a statistical estimation of relaxation profiles and provide a test for randonmess of residuals which is more accurate than other standard procedures.

Journal Article↗

Information theory and the analysis of ligand-binding data.

The phenomenological principles of information theory are used in the analysis of ligand-binding phenomena in biological macromolecules. Information maps are constructed to visualize regions of ligand chemical potential with maximum amount of information and to devise suitable experimental strategies therefrom. Extensive simulation studies and analysis of experimental data also point out the properties of information used as a weighting procedure in nonlinear least-squares analyses.

Carbon Monoxide↗

Linkage effects in a model for cell survival after radiation.

A thermodynamic treatment for the effects of radiation on cell survival is proposed. The treatment is an extension of the linear-quadratic model (K.H. Chadwick and H.P. Leenhouts, Phys. Med. Biol. 13 (1973) 78) following the principles of linkage thermodynamics (E. Di Cera, S.J. Gill and J. Wyman, Proc. Natl. Acad. Sci. U.S.A. 85 (1988) 5077). Linkage effects between chemical binding to DNA and radiation action are considered, along with the synergism between different types of radiations. A simple mathematical condition is found for the additivity of radiation doses that result in an isoeffect. The resolvability of the model parameter is investigated by simulations and statistical analysis of the distributions obtained.

Cell Cycle↗

Point perturbation analysis of experimental data.

A new method of data analysis is proposed. The method is based on discrete perturbation of experimental data points, which is used to probe the metric of the parameter hyperspace. Perturbation-induced fluctuations in the residual values are analysed by discrete Fourier transform to yield the autocorrelation function and a relaxation length for each experimental point. This parameter provides a quantitative measure of correlation and hence nonrandomness of residuals. The method is applied to the analysis of measurements of the shear viscosity of a 2,6-lutidine/water mixture near the critical point, and to the oxygen and carbon monoxide binding reactions to human hemoglobin. Relaxation profiles are constructed for several experimental data sets. Departure from random behavior in the residuals is discussed in connection with the theoretical interpretations of the phenomenon under consideration.

Analysis of Variance↗

Intracavitary dosimetry of a high-activity remote loading device with oscillating source.

Dosimetric experiments have been carried out in order to obtain the dose distribution in water around a Fletcher applicator loaded by a Buchler system containing two 137Cs 148 GBq (4 Ci) sources and one 192Ir 740 GBq (20 Ci) source. The mechanical system which controls the movement of the 192Ir source and the resulting motion of the source are described. The dose distribution around the sources was measured photographically and by a PWT Normal 0.22 cm3 ionisation chamber. The absolute dose rate was measured along the lateral axes of the sources. The measurements of exposure in water near the sources were corrected for the effect due to the finite volume of the chamber. The "quantisation method" described by Cassell (1983) was utilised to calculate the variation of the dose rate along the lateral axes of the sources. The dose distribution around both 192Ir and 137Cs sources was found to be spherical for angles greater than 40 degrees from the longitudinal axes of the sources. A simple algorithm fitting the data for the moving 192Ir source is proposed. A program written in FORTRAN IV and run on a Univac 1100/80 computer has been used to plot dose distributions on anatomical data obtained from CT images. The uncertainties of the measurements and calculations have been examined and the greatest error has been found to be 5.5%. The clinical significance of the treatment method is discussed.

Brachytherapy↗

Dose measurements and calculations of small radiation fields for 9-MV x rays.

Measurements of dose distribution for square fields with sizes ranging from 1 X 1 to 30 X 30 cm for a 9-MV x-ray beam from a Neptune 10 linear accelerator, manufactured by CGR, are reported. Special attention was paid to field sizes smaller than 4 X 4 cm, used in radiosurgery techniques. To express the dose-monitor units relationship, total, collimator, and phantom scatter correction factors were obtained by experimental measurements. A strong dependence of these factors on the smallest field sizes (less than 4 X 4 cm) was shown. Measurements of the maximum depth dose dmax, plotted as a function of field size, showed a maximum at about 5 X 5 cm, in good agreement with previous results. dmax was also measured for the smallest fields, demonstrating that the contaminating electron component of the x-ray beam was not responsible for the dmax shift. Analysis of the penumbra width of cross dose distributions, as a function of field sizes, allowed us to postulate that the dmax shift could be due to the phantom scattered photons, which in turn were generated by the collimator scattered photons. Newly derived tissue-maximum ratio and scatter-maximum ratio data were used for dose profile calculations of 2 X 2, 4 X 4, and 10 X 10 cm field sizes. The agreement between experimental and calculated data was found to be +/- 2% within the geometrical edges of the fields and +/- 6% outside of them. A dose profile from the isocenter of a 2 X 2 cm square field moving through a 360 degree rotation arc was obtained and compared with that from the center of a 125I shielded source, as measured by Ling. Advantages and problems relating to the use of x-ray beams from linear accelerators in radiosurgery are discussed.

Humans↗