PubMed Health⌕ Search

Biomedical subjects

F A Eames

Publications and source records attributed to F A Eames.

8 recordsLinked to original sources

Alzheimer dementia: quantification of energy metabolism and mobile phosphoesters with P-31 NMR spectroscopy.

To determine whether high-energy phosphate metabolism and mobile phosphoester indexes of membrane metabolism are altered in Alzheimer disease and to help resolve some inconsistencies in the literature, brain phosphate metabolite concentrations and ratios were measured in 11 patients with mild to severe dementia of the probable Alzheimer type and 14 healthy subjects. Fully relaxed, spatially localized, phosphorus-31 nuclear magnetic resonance (NMR) spectroscopy and proton (hydrogen-1) MR imaging were performed. No significant differences were found in the concentrations and relative ratios of phosphocreatine, nucleoside triphosphate, inorganic phosphate, phosphomonoester, and phosphodiesters in whole axial sections through the lateral cerebral ventricles of the brain that could not be accounted for by atrophy. There was no correlation between P-31 NMR indexes and the severity of dementia as assessed with neuropsychologic testing. High-energy phosphate and membrane metabolism, as detected in vivo with P-31 NMR spectroscopy in whole-brain sections, do not appear to play a major role in the disease process, except as a direct consequence of atrophy quantified with H-1 MR imaging.

Aged↗

Comparison of computed tomography and magnetic resonance imaging in chronic otitis media with cholesteatoma.

We prospectively studied 10 patients with chronic otitis media suspected of having cholesteatoma with computed tomography and magnetic resonance imaging to assess which imaging modality would be most specific in predicting the presence of cholesteatoma. The interpretation of images was then correlated with the operative findings. In 9 of the 10 cases, computed tomography accurately predicted the extent and destructiveness of the disease but did not consistently differentiate between cholesteatoma and associated granulation tissue. In 2 of the 10 cases, the T1-weighted magnetic resonance imaging demonstrated high signal, suggestive of cholesteatoma. In one case, magnetic resonance imaging predicted cholesteatoma on the basis of bony destruction. However, in 7 of 10 cases the scan was nonspecific for cholesteatoma. We conclude that high-resolution computed tomography remains the primary imaging modality for chronic otitis media.

Cholesteatoma↗

MR imaging of patients with implanted drug infusion pumps.

The influence of magnetic resonance (MR) imaging on the integrity and function of an implantable, programmable drug infusion pump and the distortion of the image by this device were tested. Six identical pumps were tested in magnetic fields of 1.5 T. Pump memory was not affected by the procedure. The pump rotor stalled (no infusion) as long as the device was within the magnetic field. Drug delivery resumed as programmed after the pump was removed from the field. No structural damage to the electrical or mechanical pump components was detected. The pump caused a circular image artifact (a signal dropout) within 8-10 cm of the device. The authors conclude that MR imaging is accurate if the area of interest is at least 10 cm from the pump, and that with awareness of temporary infusion cessation, it is safe to perform MR imaging in patients with this implanted pump.

Artifacts↗