PubMed Health⌕ Search

Biomedical subjects

F A Fellner

Publications and source records attributed to F A Fellner.

At least 19 recordsLinked to original sources

Evaluation of carotid artery stenosis with multisection CT and MR imaging: influence of imaging modality and postprocessing.

BACKGROUND AND PURPOSE: We prospectively evaluated the influence of different imaging techniques (time-of-flight MR angiography [TOF-MRA], contrast-enhanced MR angiography [CE-MRA], multisection CT angiography [CTA]) and postprocessing methods (maximum intensity projection [MIP], multiplanar reformation [MPR]) on carotid artery stenosis grading. MATERIALS AND METHODS: Fifty patients (34 men, 16 women) with symptomatic stenosis of the internal carotid artery were examined with a 16-section spiral CT and a 1.5T MR unit. Two MRA techniques were applied: 3D-TOF and CE-MRA. MPR was used for postprocessing with all modalities; MIP was used only with MRA. Four readers measured and calculated the percentage diameter stenosis independently according to NASCET criteria. The Wilcoxon test was used to measure interobserver variability, and the Friedman test was used to test the null-hypothesis of equality of the modalities. RESULTS: The hypothesis for global equality was rejected (P < .001). TOF-MRA and CTA assessed with MPR showed the highest concordance (difference, 0.6%; confidence interval [CI], -3.0, 4.3%), and CE-MRA with MIP and CTA showed the lowest concordance in stenosis grading (difference, 7.0%; CI, 3.4, 10.6%). MPR resulted in lower degrees of stenosis than MIP for both MRA sequences, although not statistically significant (CE, -3.0%; CI, -6.6, 0.6%; TOF, -2.2%; CI, -5.8, 1.4%). When only studies with good or excellent image quality were considered, the differences decreased, but the trends remained. CONCLUSION: Stenosis grading is dependent on the examination method and postprocessing technique. CTA and TOF-MRA evaluated with MPR revealed highest concordance.

Aged↗

Cavernous haemangiomas of the anterior visual pathways. Short review on occasion of an exceptional case.

The anterior optic pathways are rarely affected by vascular malformations. In a meticulous literature review, 42 published cases of patients with vascular malformations within optic nerves, chiasma and/or optic tract were found, 30 of them being diagnosed as cavernous haemangiomas. All of them suffered from visual disturbances; in 38.1% previous symptoms had occurred. Surgical treatment resulted in major improvement in most patients. We include a further patient with a cavernous haemangioma of the optic chiasma and left optic tract who presented with an acute defect of the right visual field and severe retro-orbital pain. We succeeded in total excision of the malformation via a neuronavigationally guided approach. In the postoperative course, vision of our patient improved immediately and was found to be completely normal three months after the surgical intervention. Considering our patient and the published cases in the literature, we are of the opinion that microsurgical excision is a safe and efficient treatment for these rare pathologies.

Adult↗

Cortical T2 signal shortening in amyotrophic lateral sclerosis is not due to iron deposits.

Signal shortening of the motor cortex in T2-weighted MR images is a frequent finding in patients with amyotrophic lateral sclerosis (ALS). The cause of signal shortening in ALS is unknown, although iron deposits have been suggested. To test this hypothesis, we acquired T2*-weighted gradient-echo (GRE) MR images in addition to T2-weighted turbo spin-echo in 69 patients with ALS. Signal shortening in T2-weighted images was found in 31 patients. In T2*-weighted GRE images, only three patients had signal shortening. One patient with additional bifrontal haemorrhage had frontal but no motor cortex signal shortening. Iron deposits do not cause cortical signal shortening in patients with ALS predominantly. Other factors are presumably more important in the generation of cortical T2 shortening in ALS.

Adult↗

Carotid artery calcium: accuracy of a calcium score by computed tomography-an in vitro study with comparison to sonography and histology.

OBJECTIVES: The aim of this study was to compare methods of quantifying calcification of the internal carotid artery. MATERIALS AND METHODS: We examined 92 internal carotid artery endarterectomy specimens. Grey scale median (GSM) values were calculated from optimized B-mode scans. The degree of calcification was assessed using radiographic calcification grading. Plaques were processed histologically, and classified into: (1) calcium-rich hard plaques, (2) lipid-rich soft plaques, and (3) combined plaques. The specimens were scanned in CT-scanner. The calcium score was determined as described by Agatston. RESULTS: Histopathology and GSM results concurred in 39 out of 92 cases (kappa=0.088). There was no significant correlation between the calcium score and the median GSM value (R=0.005; P=0.959). Histology and CT morphology showed a significant concordance (P<0.001). Also CT and radiomorphological classification showed close agreement (R=0.628, P<0.001). CONCLUSIONS: Calcium scores calculated using CT morphology enable precise in vitro evaluation of the calcium content of plaques in the internal carotid. In contrast, grey scale median values do not adequately reflect calcification of plaques.

Aged↗

Distinct supratentorial lesions mimicking cerebral gliomas.

BACKGROUND: Various supratentorial pathological conditions can mimic neoplastic cerebral lesions clinically as well as radiologically. Analysis of the neuroradiological findings, the clinical history, laboratory and other paraclinical data mostly help to narrow down the diagnosis of cerebral pathologies. Sometimes, however, histopathological analysis of the operative specimen after surgery reveals unexpected findings. PATIENTS AND FINDINGS: In a series of 197 operative procedures performed for glioma surgery between August 2000 and August 2002 we found six distinct cases mimicking supratentorial tumours. Clinicoradiological findings had suggested a neoplastic gliomatous process in all cases. But histopathological examination revealed that in reality one patient had been affected by a stroke, two by hypertensive encephalopathy, and one by radiation necrosis; multiple sclerosis was the underlying pathology in two patients. INTERPRETATION: Conditions which show features similar to those of neoplastic cerebral lesions require advanced magnetic resonance imaging (MRI). The benefit of such sophisticated imaging in relation to the costs is an important issue in this context. Further research in the field of modern image modalities is necessary to evaluate these noninvasive techniques for specification of intracerebral lesions.

Adult↗

Comparison of whole-body MRI with automatic moving table technique and bone scintigraphy for screening for bone metastases in patients with breast cancer.

The aim of this study was presentation of a whole-body MRI technique with a moving table as a screening tool for bone metastases in patients with breast cancer. Twenty-two patients with breast carcinoma underwent both a planar whole-body bone scintigraphy and whole-body MRI at 1.5 T. The MRI images were acquired with a moving table at six different anatomical positions within a measurement time of 20 min. Coronal images were acquired using a short-tau inversion recovery sequence, accomplished by an axial T2-weighted turbo-spin-echo sequence through the head, and a T1-weighted opposed-phase sagittal 2D fast low-angle shot sequence covering the whole spine. The MRI findings indicating bone metastases were compared with findings from bone scintigraphy. Metastatic lesions were confirmed by follow-up examinations over 1 year. Twelve patients showed bone metastases. Whole-body MRI was superior to bone scintigraphy in predicting lesion origin with a sensitivity of 92% (bone scintigraphy 83%), a specificity of 90% (scintigraphy 80%) and an accuracy of 91% (scintigraphy 82%). The MRI showed additional findings such as metastases of the lung and liver. Whole-body MRI with moving table technique may be an effective method of total body screening for bone in selected patients with breast carcinoma and a high risk of distant metastases, although with the higher costs of MRI bone scintigraphy must still be considered as the first method for screening patients with breast cancer.

Aged↗

[VIBE with parallel acquisition technique - a novel approach to dynamic contrast-enhanced MR imaging of the liver].

PURPOSE: The VIBE (volume interpolated breath-hold examination) sequence in combination with parallel acquisition technique (iPAT: integrated parallel acquisition technique) allows dynamic contrast-enhanced MRI of the liver with high temporal and spatial resolution. The aim of this study was to obtain first clinical experience with this technique for the detection and characterization of focal liver lesions. MATERIALS AND METHODS: We examined 10 consecutive patients using a 1.5 T MR system (gradient field strength 30 mT/m) with a phased-array coil combination. Following sequences were acquired: T 2 -w TSE and T 1 -w FLASH, after administration of gadolinium, 6 VIBE sequences with iPAT (TR/TE/matrix/partition thickness/time of acquisition: 6.2 ms/ 3.2 ms/256 x 192/4 mm/13 s), as well as T 1 -weighted FLASH with fat saturation. Two observers evaluated the different sequences concerning the number of lesions and their dignity. Following lesions were found: hepatocellular carcinoma (5 patients), hemangioma (2), metastasis (1), cyst (1), adenoma (1). RESULTS: The VIBE sequences were superior for the detection of lesions with arterial hyperperfusion with a total of 33 focal lesions. 21 lesions were found with T 2 -w TSE and 20 with plain T 1 -weighted FLASH. Diagnostic accuracy increased with the VIBE sequence in comparison to the other sequences. CONCLUSION: VIBE with iPAT allows MR imaging of the liver with high spatial and temporal resolution providing dynamic contrast-enhanced information about the whole liver. This may lead to improved detection of liver lesions, especially hepatocellular carcinoma.

Adenoma↗

[MR imaging of pancreatic lesions with Mn-DPDP. A histopathologic correlation].

PURPOSE: To examine the diagnostic accuracy of pancreatic lesions using mangafodipir-trisodium (Mn-DPDP) enhanced MR imaging. The imaging results were correlated with the histopathological results. MATERIAL AND METHODS: 40 patients with suspicion of pancreatic carcinoma were examined with MRI before and after i. v. administration of Mn-DPDP (Philips Gyroscan ACS NT 1.5 T, phased array body-coil: TSE T 2 with and without SPIR, TR 2000 ms, TE 120ms; FFE T 1 breathhold, TR 115 ms, TE 4.6 ms; MRCP, TR 6000 ms, TE 1200 ms; Teslascan i. v. 5 micromol Mn/kg; FFE T 1 breathhold SPIR, TR 140 ms, TE 4,6 ms). Two observers evaluated in consensus the number and characteristics of focal pancreatic lesions. The MR findings were correlated with histopathological findings retrospectively. RESULTS: The following lesions were found: adenocarcinoma (19), pancreatitis (8), adenocarcinoma within pancreatitis (3), insulinoma (2), hematoma (1), papillitis stenosans (1), signet ring cell carcinoma (1), metastasis of rectal carcinoma (1), papillary mesothelioma (1). In three patients there was no pathological finding. Mn-DPDP enhanced MRI showed a sensitivity of 100 % and a specificity of 56 %. CONCLUSION: Mn-DPDP enhanced MRI in conjunction with MRCP showed a high sensitivity for the detection of pancreatic lesions. However, the specificity is low, thus recommending Mn-DPDP enhanced MRI only as a complementary imaging method.

Ampulla of Vater↗

[CT-angiography of the carotid artery: First results with a novel 16-slice-spiral-CT scanner].

PURPOSE: To evaluate a novel multislice CT system (16-slice-spiral-CT scanner) for the diagnosis of carotid artery stenosis. MATERIAL AND METHODS: Five patients with symptomatic atherosclerotic disease of the carotid arteries were examined with a 16- slice-spiral-CT scanner. Collimation was 16 x 0.75 mm, table speed 36 mm/s (pitch of 1.5), rotation time 0.5 s, tube current was 160 eff.mAs at 120 kV. 60 ml of contrast material were injected with a power injector followed by a saline flush. The start delay was measured with test bolus method (20 ml CM). Interactive multiplanar reformation (iMPR) and thin slab MIP as well as volume rendering were used for image evaluation and presentation. RESULTS: Scan time was 9 s for a range of 300 mm. This allowed imaging the whole length of the carotid artery (aortic arch to circle of Willis) in a true arterial phase. Pulsation artefacts did not impair the evaluation of the vessels at the level of the aortic arch. Overall image quality of both "source images" and 3D-reconstructions was excellent, due to a reduced voxel size of 0.03 mm (3). Image evaluation and postprocessing (iMPR, MIP) was done within 15 min. iMPR was highly accurate for demonstrating plaque morphology and determining the percentage of the stenosis. CONCLUSION: For the first time, true arterial phase images of the entire carotid artery with high spatial resolution could be acquired using a 16-slice-spiral-CT scanner. This method offers the potential to replace catheter angiography in the evaluation of carotid artery stenosis.

Blood Flow Velocity↗

A high-resolution phantom for MRI.

Assessment of spatial resolution is an important step to test the performance of new sequence techniques-especially ultrafast techniques with dedicated k-space trajectories or interpolation algorithms. Measurement of the modulation transfer function (MTF) is a rather difficult procedure, but using suitable resolution phantoms allows a simple visual evaluation of spatial resolution. In contrast to commonly used test objects with a very restricted number of resolution patterns we developed a phantom containing resolution patterns from 0.1 to 1.5 mm in steps of 0.1 mm. One resolution pattern consists of five parallel Plexiglas strips with the distance of the strips being equal to their thickness. Together with a Plexiglas cuboid the resolution patterns are mounted on a Plexiglas plate on the bottom of the cylindrical phantom. An aqueous solution of manganese chloride is used to fill the phantom. High resolution cross sections (pixel size: 50 microm) through the resolution patterns were measured to confirm the correct dimensions of the phantom. To verify the appropriateness of the 0.1 and 0.2 mm stacks micro-CT images with a pixel size of 25 microm were acquired additionally for both patterns. Besides visual inspection evaluation of the profile function of signal intensity across the stacks demonstrates that the resolution patterns are sufficiently correct. T(1)-weighted SE sequences with slightly different pixel sizes as well as T(1)- and T(2*)- weighted gradient echo sequences were applied to demonstrate some possible applications of this phantom. In conclusion, the proposed phantom is well suited to assess the spatial resolution qualitatively (i.e., visually) and quantitatively over a wide range in steps of 0.1 mm.

Humans↗

Gamna-Gandy bodies of the spleen detected with MR imaging: a case report.

We report a case of a female patient with portal hypertension due to liver cirrhosis. In this case, MR imaging revealed small siderotic nodules of the spleen, called Gamna-Gandy bodies. These lesions are found in patients with portal vein or splenic vein thrombosis, hemolytic anemia, leukemia, or lymphoma, patients receiving blood transfusions, acquired hemochromatosis, or paroxysmal nocturnal hemoglobinuria. There are only few reports in the literature about these siderotic nodules which are not very familiar. MR imaging seems to be the superior imaging method for detection of these lesions. It is important to consider Gamna-Gandy bodies in the differential diagnosis of portal hypertension and the other diseases mentioned above.

Aged↗

Direct MR arthrography of the shoulder: 2D vs. 3D gradient-echo imaging.

The aim of this study was to determine the value of a fat suppressed 3D gradient-echo sequence (GRE) data set in comparison to a 2D GRE sequence in direct MR arthrography of the shoulder. For this purpose we examined 50 consecutive patients with subacute or chronic disorders of the shoulder using a 1.5 T scanner: Transverse T1-weighted 2D (slice thickness 4 mm) and 3D GRE (slice thickness 1.5 mm reconstructed from 3 mm), oblique coronal T2- and T1-weighted turbo spin-echo (TSE) and sagittal T1-weighted TSE with fat saturation were applied. Visual image analysis of anatomical and pathological structures was performed by two independent observers. A correlation to surgical results was available in 21 patients. Transverse GRE sequences were well suited for analysis of the anterior/posterior labrum, the middle glenohumeral ligament, and cartilage. 3D GRE with fat suppression was slightly superior to 2D GRE without fat suppression in the evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament, whereas for cartilage no significant differences were found between both sequences. Concerning pathological findings, in most of the cases 2D delivered the same results as 3D. In conclusion, a T1-weighted 3D GRE data set with fat saturation in transverse orientation may be useful for evaluation of the anterior/posterior labrum, and the middle glenohumeral ligament. However, similar measured slice thickness of 3 mm-even if interpolated to 1.5 mm-compared to a 2D sequence with 4 mm does not provide significant diagnostic advantages.

Adolescent↗

A low-field MR system in acute traumatological imaging in radiology. Technical note.

PURPOSE: In this paper initial clinical observations with the application of a new low-field MR system in acute musculoskeletal imaging in radiology are presented. MATERIALS AND METHODS: This system is designed as a three-sided open permanent magnet with a revolving table. Main magnetic field strength is 0.2 T, maximal gradient field strength 20 mT/m, and minimal gradient rise time is 800 microseconds. First clinical experiences in 25 patients with acute trauma of peripheral joints were obtained. The following sequences were applied: gradient-echo (GRE) STIR, T1-weighted spin-echo, and PD- and T2-weighted turbo spin-echo. Correlation with the findings of high-field MR (1.5 T), plain radiograms (including stress views), CT or ultrasound was available in each patient confirming the low-field diagnoses. Furthermore, phantom measurements were performed to verify the spatial resolution of the system for some sequences with typical measurement parameters. DISCUSSION: This low-field system has several advantages: fast and economic installation, limited required space, easy operation, and high patient comfort. The medical benefit of such a system integrated in the traumatological suite of a radiological department seems to be evident due to the impact on the early initiation of the correct therapy which avoids additional diagnostic procedures and therefore may reduce costs. Implementation of such a system may be useful, if installation of an additional high-field scanner is not possible due to economic considerations.

Adolescent↗