PubMed Health⌕ Search

Biomedical subjects

F Ballester

Publications and source records attributed to F Ballester.

At least 37 records · Page 2Linked to original sources

[Relation between clinical symptoms and the results of a computerized dynamic posturography].

The computerized dynamic posturography (CDP) is a quantitative method for the evaluation of balance function under different conditions that simulates the ones found in normal life. Its applications are centered in the diagnosis and rehabilitation of balance dysfunction. We report a descriptive study on 96 patients with balance disorders who underwent a CDP, stablishing a relation between their main symptoms and the results in the test. A high percentage of patients with symptoms that suggested peripheral vestibular pathology did not present alterations at this level by means of the CDP. However a considerable number of patients who referred symptoms classically related to a non vestibular origin did show an alteration at this level.

Adult↗

Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources.

The low dose rate CDC-type miniature cylindrical 137Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte Carlo GEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is lambda = 1.113 +/- 0.003cGyh(-1) U(-1), and the value for the three bead source is A= 1.103 +/- 0.003cGyh(-1) U(-1). Finally, for the treatment planning systems based on Sievert-type algorithms, the attenuation coefficients that best reproduce Monte Carlo dose rate distribution are given.

Air↗

The EMECAM project: a multicentre study on air pollution and mortality in Spain: combined results for particulates and for sulfur dioxide.

OBJECTIVE: The EMECAM study is a collaborative effort to evaluate the impact of air pollution on mortality in Spain. In this paper the combined results are presented for the short term effects of particulates and sulfur dioxide on both daily mortality for all and for specific causes. METHODS: The relation between daily mortality for all causes, cardiovascular diseases, and respiratory diseases, and air pollution for particulates (daily concentrations) and SO(2) (24 and 1 hour concentrations) was assessed in 13 Spanish cities for the period 1990-6. With a standardised method, magnitude of association in each city was estimated by Poisson regression in a generalised additive model. Local estimates were obtained from both single and two pollutant analyses. Lastly, combined estimates for each cause and pollutant were obtained. RESULTS: For combined results, in single pollutant models a 10 microg/m(3) increase in the concentration of the mean of the concurrent and one day lag for black smoke was associated with a 0.8% (95% confidence interval (95% CI) 0.4 to 1.1%) increase in total mortality. The estimates for total suspended particles (TSPs) and particulate matter of aerodynamic diameter <10 microm (PM(10)) and total mortality were slightly lower. The same increase in concentrations of SO(2) was associated with a 0.5% increase in daily deaths. For groups of specific causes, higher estimations were found, specially for respiratory conditions. Peak concentrations of SO(2) showed significant associations with the three groups of mortality. When two pollutant analyses were performed, estimates for particulates, specially for black smoke, did not substantially change. The estimates for daily concentrations of SO(2) were greatly reduced, but, on the contrary, the association with peak concentrations of SO(2) did not show any change. CONCLUSIONS: There is an association between mortality and pollution through particulates among city populations in Spain. Peak rather than daily concentrations of SO(2) were related to mortality. Results suggest that populations in Spanish cities are exposed to health risks derived from air pollution.

Air Pollutants↗

Monte Carlo dosimetry of the Buchler high dose rate 192Ir source.

In this study a complete set of dosimetric data is presented for the high dose rate (HDR) source from Amersham used in the Buchler remote afterloading HDR unit. These data have been calculated by means of the Monte Carlo simulation code GEANT taking into account the detailed geometry of the source. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been calculated. Quantities determined are: dose rate constant, radial dose function, anisotropy function, anisotropy factor and anisotropy constant. The dose rate distributions of the Buchler HDR source are compared with those of other HDR sources used in brachytherapy, showing that the differences are large in zones near the long source axis due to oblique filtration. These Monte Carlo simulated data in water can be used for clinical applications.

Anisotropy↗

Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type 137Cs sources.

Basic dosimetric data for the Walstam CDC.K-type low dose rate 137Cs sources in water have been calculated using Monte Carlo techniques. These sources, CDC.K1 -K3 and CDC.K4, are widely used in a range of applicators and moulds for the treatment of intracavitary and superficial cancers. Our purpose is to improve existing data about these sources using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water have been calculated around these sources and are presented as conventional 2D Cartesian look-up tables. Also the AAPM Task Group 43 formalism for dose calculation has been applied. The calculated dose rate constant for the CDC.K1-K3 source is A = 1.106 +/- 0.001 cGy h(-1) U(-1), and for the CDC.K4 source, A = 1.092 +/- 0.001 cGy h(-1) U(-1). The anisotropy of the sources are accurately studied and F(r, theta) tables are given. Also phi an(r) factors are presented. The radial dose functions are given as a polynomial fit to the calculated data up to 15 cm. Best-fit values of coefficients suitable for use in Sievert integral calculations have been derived.

Algorithms↗

Assessment of the linear reference air kerma rate of 192Ir wires.

In this study, a procedure to test the linear reference air kerma rate of 192Ir wires using a well-type chamber is described. The method is based on a special lead insert with a 1 cm acrylic aperture that provides a differential response of the well chamber. The wire is considered divided into 1 cm parts. Using an external positioning system it is possible to place every part of the wire at the aperture position in the lead insert allowing measurement of each 1 cm making up the length of the wire. By means of a set of equations that take into account the contribution of all parts of the wire, in all possible positions, the relative linear reference air kerma rate is obtained. The estimated uncertainties of this procedure are about 2 to 3%. So, a well chamber and the specific inserts allow the measurements of total and linear reference air kerma rate for 192Ir wires.

Iridium Radioisotopes↗

Confounding and effect modification in the short-term effects of ambient particles on total mortality: results from 29 European cities within the APHEA2 project.

We present the results of the Air Pollution and Health: A European Approach 2 (APHEA2) project on short-term effects of ambient particles on mortality with emphasis on effect modification. We used daily measurements for particulate matter less than 10 microm in aerodynamic diameter (PM10) and/or black smoke from 29 European cities. We considered confounding from other pollutants as well as meteorologic and chronologic variables. We investigated several variables describing the cities' pollution, climate, population, and geography as potential effect modifiers. For the individual city analysis, generalized additive models extending Poisson regression, using a smoother to control for seasonal patterns, were applied. To provide quantitative summaries of the results and explain remaining heterogeneity, we applied second-stage regression models. The estimated increase in the daily number of deaths for all ages for a 10 microg/m3 increase in daily PM10 or black smoke concentrations was 0.6% [95% confidence interval (CI) = 0.4-0.8%], whereas for the elderly it was slightly higher. We found important effect modification for several of the variables studied. Thus, in a city with low average NO2, the estimated increase in daily mortality for an increase of 10 microg/m3 in PM10 was 0.19 (95% CI = 0.00-0.41), whereas in a city with high average NO2 it was 0.80% (95% CI = 0.67-0.93%); in a relatively cold climate the corresponding effect was 0.29% (95% CI = 0.16-0.42), whereas in a warm climate it was 0.82% (95% CI = 0.69-0.96); in a city with low standardized mortality rate it was 0.80% (95% CI = 0.65-0.95%), and in one with a high rate it was 0.43% (95% CI = 0.24-0.62). Our results confirm those previously reported on the effects of ambient particles on mortality. Furthermore, they show that the heterogeneity found in the effect parameters among cities reflects real effect modification, which is explained by specific city characteristics.

Aged↗

Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism.

The purpose of this study is to find fitted functional forms to the anisotropy function, F(r, theta), and the radial dose function, g(r), in order to characterize dose-rate distributions around all the high-intensity 192Ir sources currently in use. Dosimetry data are at present available as tables for: the microSelectron HDR ("classic" and "new" design models), the PDR source, and the VariSource HDR source, expressed in terms of the AAPM Task Group No. 43 recommendations. There is only one paper out which introduces a functional form to fit the anisotropy function, but only for symmetric sources with respect to the transverse axis. However, dosimetric data of the HDR and PDR sources mentioned above cannot be reproduced with these functional forms. In our study F(r,theta) and g(r) published data are fitted with functional forms in such a way that appropriate limits are reached for both functions and the maximum fit error approaches the data uncertainty. The average fit error is less than 1% in all cases. These functional forms make handling data easier within the treatment planning system, avoiding the use of tabulated data.

Anisotropy↗

Dosimetry characteristics of the Plus and 12i Gammamed PDR 192Ir sources.

In this study a complete set of dosimetric data for the Plus and 12i Gammamed PDR (pulsed dose rate) 192Ir sources is presented. These data have been calculated using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water around these sources were calculated and are presented in form of conventional two dimensional (2D) Cartesian look-up tables. All dosimetric quantities recommended by the AAPM Task Group 43 report have been also calculated. These quantities are dose rate constant, radial dose function, anisotropy function and anisotropy factor. The dose rate distribution of the 12i source was compared with the corresponding data for the microselectron PDR source showing large differences between both sources.

Air↗

Technical note: Monte-Carlo dosimetry of the HDR 12i and Plus 192Ir sources.

In this study a complete set of dosimetric data for the GammaMed high dose rate (HDR) 12i and Plus 192Ir sources are presented. These data have been calculated by means of the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water are presented as conventional two dimensional (2D) Cartesian look-up tables, and in the TG43 formalism.

Anisotropy↗

Cutaneous infection caused by Aspergillus ustus, an emerging opportunistic fungus in immunosuppressed patients.

We report a case of primary cutaneous infection by the emerging fungus Aspergillus ustus in an immunosuppressed patient after a domestic accident. The patient failed to respond to itraconazole and died before receiving a new treatment with amphotericin B. There have been eight other cases reported since 1973, and only two patients survived the infection. In vitro susceptibility testing of seven antifungal drugs showed that terbinafine and the new azole derivative UR-9825 were the most active against this fungus.

Aged↗

Air pollution and emergency hospital admissions for cardiovascular diseases in Valencia, Spain.

STUDY OBJECTIVE: To estimate the short-term association between air pollution levels and emergency hospital admissions for cardiovascular diseases in Valencia, within 1994-1996 period. DESIGN: Daily levels of air pollution and emergency admissions for cardiovascular diseases were related to using an ecological time series design. The number of admissions was obtained from the hospital records database. Selected groups of causes were all cardiovascular diseases, heart admissions, and admissions for cerebrovascular diseases. The number of admissions for digestive diseases was used as control. Pollutants were black smoke, sulphur dioxide (SO(2)), nitrogen dioxide (NO(2)), carbon monoxide (CO) and ozone (O(3)). Magnitude of association was estimated by Poisson autoregressive regression. Estimations were calculated according the hottest (May to October) and the coldest (November to April) periods. SETTING: City of Valencia, Spain, about 750,000 inhabitants. PARTICIPANTS: People being admitted to the two major hospitals in the city, with a catchment area of nearly 400,000 inhabitants. MAIN RESULTS: For the whole period, a significant association for SO(2)-24 h was found so a rise in its levels of 10 microg/m(3) was associated with an increment of 3% (95%CI 0.4 to 5.7%) in the expected number of cardiovascular admissions. A significant association for black smoke, SO(2)-24 h, SO(2)-1 h, and CO-1 h was found in the hottest semester. All these associations were verified with a lag of two days. The estimates of the associations for particles, SO(2), and CO were affected by the inclusion of the other pollutants in their models. NO(2) was independently associated with cerebrovascular admissions. There were no significant associations between air pollution and admissions for digestive diseases. CONCLUSIONS: Current levels of air pollution and emergency cardiovascular admissions are significantly related in Valencia.

Air Pollutants↗

Comparing meta-analysis and ecological-longitudinal analysis in time-series studies. A case study of the effects of air pollution on mortality in three Spanish cities.

STUDY OBJECTIVE: The objective of this paper is to introduce a different approach, called the ecological-longitudinal, to carrying out pooled analysis in time series ecological studies. Because it gives a larger number of data points and, hence, increases the statistical power of the analysis, this approach, unlike conventional ones, allows the complementation of aspects such as accommodation of random effect models, of lags, of interaction between pollutants and between pollutants and meteorological variables, that are hardly implemented in conventional approaches. DESIGN: The approach is illustrated by providing quantitative estimates of the short-term effects of air pollution on mortality in three Spanish cities, Barcelona, Valencia and Vigo, for the period 1992-1994. Because the dependent variable was a count, a Poisson generalised linear model was first specified. Several modelling issues are worth mentioning. Firstly, because the relations between mortality and explanatory variables were non-linear, cubic splines were used for covariate control, leading to a generalised additive model, GAM. Secondly, the effects of the predictors on the response were allowed to occur with some lag. Thirdly, the residual autocorrelation, because of imperfect control, was controlled for by means of an autoregressive Poisson GAM. Finally, the longitudinal design demanded the consideration of the existence of individual heterogeneity, requiring the consideration of mixed models. MAIN RESULTS: The estimates of the relative risks obtained from the individual analyses varied across cities, particularly those associated with sulphur dioxide. The highest relative risks corresponded to black smoke in Valencia. These estimates were higher than those obtained from the ecological-longitudinal analysis. Relative risks estimated from this latter analysis were practically identical across cities, 1.00638 (95% confidence intervals 1.0002, 1.0011) for a black smoke increase of 10 microg/m(3) and 1.00415 (95% CI 1.0001, 1.0007) for a increase of 10 microg/m(3) of sulphur dioxide. Because the statistical power is higher than in the individual analysis more interactions were statistically significant, especially those among air pollutants and meteorological variables. CONCLUSIONS: Air pollutant levels were related to mortality in the three cities of the study, Barcelona, Valencia and Vigo. These results were consistent with similar studies in other cities, with other multicentric studies and coherent with both, previous individual, for each city, and multicentric studies for all three cities.

Air Pollutants↗

The concentration-response relation between air pollution and daily deaths.

Studies on three continents have reported associations between various measures of airborne particles and daily deaths. Sulfur dioxide has also been associated with daily deaths, particularly in Europe. Questions remain about the shape of those associations, particularly whether there are thresholds at low levels. We examined the association of daily concentrations of black smoke and SO(2) with daily deaths in eight Spanish cities (Barcelona, Bilbao, Castellón, Gijón, Oviedo, Valencia, Vitoria, and Zaragoza) with different climates and different environmental and social characteristics. We used nonparametric smoothing to estimate the shape of the concentration-response curve in each city and combined those results using a metasmoothing technique developed by Schwartz and Zanobetti. We extended their method to incorporate random variance components. Black smoke had a nearly linear association with daily deaths, with no evidence of a threshold. A 10 microg/m(3) increase in black smoke was associated with a 0.88% increase in daily deaths (95% confidence interval, 0.56%-1.20%). SO(2) had a less plausible association: Daily deaths increased at very low concentrations, but leveled off and then decreased at higher concentrations. These findings held in both one- and two-pollutant models and held whether we optimized our weather and seasonal model in each city or used the same smoothing parameters in each city. We conclude that the association with particle levels is more convincing than for SO(2), and without a threshold. Linear models provide an adequate estimation of the effect of particulate air pollution on mortality at low to moderate concentrations.

Adolescent↗

Length of stay in a hospital emergency room due to asthma and chronic obstructive pulmonary disease: implications for air pollution studies.

The aim of this paper is to model the length of stay following hospital emergency due to asthma and chronic obstructive pulmonary disease (COPD) as well as those factors relating to its duration. Clinical records of all those hospital emergencies for asthma and COPD in people aged over 14 at the Hospital Clinico Universitario of Valencia (HCUV) during years 1993-1995 were reviewed. Data were analysed by entry and discharge time, sex, age and destination. Parametric survival models (exponential, Weibull and log-normal) were used for each diagnostic. Percentiles and relative percentiles were calculated; 1369 asthma emergencies and 2734 cases COPD were observed. The mean length of stay was 5.21 hours for asthma and 6.32 for COPD log-normal model was the best parametric model. Lengths of stay are greater for those hospital admitted. Stays, in cases of asthma, were shorter during months of August and November, with no differences for other variables. Also a shorter duration of stay for the month of August was found. Women are seen to stay for longer periods than men. Time modelling of emergency admission for asthma and COPD permits its use in the determining of the dates of incidence for episodes of asthma and COPD based on hospital admissions data, as seeing a median of delay in emergency rooms greater than 6 hours. For studies on air pollution impact these results imply that all those admissions during the early hours of the morning should be categorised as events of the previous day.

Adolescent↗

Dosimetric characteristics of backscattered electrons in lead.

In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) was defined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy incident on the scatterer between 0.5 and 1.5 MeV, keeping practically constant above this energy up to 3 MeV. Backscattered electron energy spectra and depth dose curves in the 'up-stream' direction have been obtained at the various energies of the primary electron beam striking on the lead scatterer. The results of this work are compared with previously published data.

Algorithms↗

A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS.

The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically along-away tables). Also, the dose calculation formalism endorsed by the Interstitial Collaborative Working Group and the AAPM Task Group 43 have been calculated. The calculated dose rate constant for this source is lambda = 1.096 +/- 0.002 cGy h(-1) U(-1). The anisotropy function results in about 50% deviations from isotropy at positions near the long axis of the source. The radial dose function is given as a polynomial that reproduces the calculated data up to 20 cm. Best-fit values of attenuation coefficients suitable for use in Sievert integral calculations have been derived.

Air↗