PubMed Health⌕ Search

Biomedical subjects

F Bauer

Publications and source records attributed to F Bauer.

At least 19 recordsLinked to original sources

A dielectric polymer with high electric energy density and fast discharge speed.

Dielectric polymers with high dipole density have the potential to achieve very high energy density, which is required in many modern electronics and electric systems. We demonstrate that a very high energy density with fast discharge speed and low loss can be obtained in defect-modified poly(vinylidene fluoride) polymers. This is achieved by combining nonpolar and polar molecular structural changes of the polymer with the proper dielectric constants, to avoid the electric displacement saturation at electric fields well below the breakdown field. The results indicate that a very high dielectric constant may not be desirable to reach a very high energy density.

Journal Article↗

Azimuthal angle correlations for rapidity separated Hadron pairs in d+Au collisions at square root of sNN=200 GeV.

Deuteron-gold (d+Au) collisions at the Relativistic Heavy Ion Collider provide ideal platforms for testing QCD theories in dense nuclear matter at high energy. In particular, models suggesting strong saturation effects for partons carrying small nucleon momentum fraction (x) predict modifications to jet production at forward rapidity (deuteron-going direction) in d+Au collisions. We report on two-particle azimuthal angle correlations between charged hadrons at forward/backward (deuteron/gold going direction) rapidity and charged hadrons at midrapidity in d+Au and p+p collisions at square root of sNN=200 GeV. Jet structures observed in the correlations are quantified in terms of the conditional yield and angular width of away-side partners. The kinematic region studied here samples partons in the gold nucleus with x~0.1 to ~0.01. Within this range, we find no x dependence of the jet structure in d+Au collisions.

Journal Article↗

J/psi production and nuclear effects for d + Au and p + p collisions at square root of S(NN) = 200 GeV.

J/psi production in d + Au and p + p collisions at square root of S(NN) = 200 GeV has been measured by the PHENIX experiment at rapidities -2.2 < y < +2.4. The cross sections and nuclear dependence of J/psi production versus rapidity, transverse momentum, and centrality are obtained and compared to lower energy p + A results and to theoretical models. The observed nuclear dependence in d + Au collisions is found to be modest, suggesting that the absorption in the final state is weak and the shadowing of the gluon distributions is small and consistent with Dokshitzer-Gribov-Lipatov-Altarelli-Parisi-based parametrizations that fit deep-inelastic scattering and Drell-Yan data at lower energies.

Journal Article↗

[Balloon aortic valvuloplasty in the adult. Immediate results and in-hospital complications in the latest series of 141 consecutive patients at the University Hospital of Rouen (2002-2005)].

UNLABELLED: With the aging population, elderly patients with degenerative, severely calcified, and symptomatic aortic stenosis are becoming a frequent problem in medical decision making, particularly because many are declined for surgical valve replacement. For these patients, balloon aortic dilatation could be a palliative treatment. PATIENTS AND METHODS: we analyzed retrospectively our techniques and complications during hospitalization for percutaneous aortic balloon dilatation in 141 consecutive patients (45% women, mean age 83 +/- 10 y) from January 2002 to April 2005. The Parsonnet's score was 41 +/- 8 and the Euroscore was 10 +/- 2. We excluded the patients enrolled for percutaneous aortic valve implantation. This technique was performed under local anesthesia, from retrograde or antegrade approach. Rapid pacing stimulation (220/bpm) with a pacing-lead placed in the right ventricle was performed during balloon inflation. RESULTS: the aortic valve area was increased from 0.59 +/- 0.19 to 1.02 +/- 0.34 cm2 (p < 0.001) and the transvalvular mean gradient decreased from 49.3 +/- 21.2 to 22.2 +/- 11.8 mmHg (p < 0.001). Six patients (4%) died (3 during aortic valve dilatation) and 9 patients (6%) had non fatal complications: 2 transitory strokes, 8 non surgical vascular complications and 5 episodes of atrio-ventricular complete block (these complication were non exclusive). The patients were discharged at 5, 6 +/- 3 days. CONCLUSION: In the hands of skilled operators, aortic percutaneous balloon dilatation has become a simple technique, associated with a low risk of complications despite a very ill patient population. This technique remains a good option for a number of patients before the onset of percutaneous aortic valve implantation.

Aged, 80 and over↗

Measurement of transverse single-spin asymmetries for midrapidity production of neutral pions and charged hadrons in polarized p + p collisions at square root(s) = 200 GeV.

Transverse single-spin asymmetries to probe the transverse-spin structure of the proton have been measured for neutral pions and nonidentified charged hadrons from polarized proton-proton collisions at midrapidity and square root(s) = 200 GeV. The data cover a transverse momentum (pT) range 1.0-5.0 GeV/c for neutral pions and 0.5-5.0 GeV/c for charged hadrons, at a Feynman-x value of approximately zero. The asymmetries seen in this previously unexplored kinematic region are consistent with zero within errors of a few percent. In addition, the inclusive charged hadron cross section at midrapidity from 0.5 < pT < 7.0 GeV/c is presented and compared to next-to-leading order perturbative QCD (pQCD) calculations. Successful description of the unpolarized cross section above approximately 2 GeV/c suggests that pQCD is applicable in the interpretation of the asymmetry results in the relevant kinematic range.

Journal Article↗

Saturation of azimuthal anisotropy in Au + Au collisions at (square root)s(NN) = 62-200 GeV.

New measurements are presented for charged hadron azimuthal correlations at midrapidity in Au+Au collisions at (square root)s(NN) = 62.4 and 200 GeV. They are compared to earlier measurements obtained at (square root)s(NN) = 130 GeV and in Pb + Pb collisions at (square root)s(NN) = 17.2 GeV. Sizeable anisotropies are observed with centrality and transverse momentum (pT) dependence characteristic of elliptic flow (upsilon2). For a broad range of centralities, the observed magnitudes and trends of the differential anisotropy, upsilon2(pT), change very little over the collision energy range (square root)s(NN) = 62-200 GeV, indicating saturation of the excitation function for upsilon2 at these energies. Such a saturation may be indicative of the dominance of a very soft equation of state for (square root)s(NN) approximately 60-200 GeV.

Journal Article↗

Nuclear modification factors for hadrons at forward and backward rapidities in deuteron-gold collisions at sqrt[s(NN)]=200 GeV.

We report on charged hadron production in deuteron-gold reactions at sqrt[s(NN)]=200 GeV. Our measurements in the deuteron direction cover 1.4<eta<2.2, referred to as forward rapidity, and in the gold direction -2.0<eta<-1.4, referred to as backward rapidity, and a transverse momentum range p(T)=0.5-4.0 GeV/c. We compare the relative yields for different deuteron-gold collision centrality classes. We observe a suppression relative to binary collision scaling at forward rapidity, sensitive to low momentum fraction (x) partons in the gold nucleus, and an enhancement at backward rapidity, sensitive to high momentum fraction partons in the gold nucleus.

Journal Article↗

Double helicity asymmetry in inclusive midrapidity pi0 production for polarized p+p collisions at square root s = 200 GeV.

We present a measurement of the double longitudinal spin asymmetry in inclusive pi(0) production in polarized proton-proton collisions at sqrt[s]=200 GeV. The data were taken at the Relativistic Heavy Ion Collider with average beam polarizations of 0.27. The measurements are the first in a program to study the longitudinal spin structure of the proton, using strongly interacting probes, at collider energies. The asymmetry is presented for transverse momenta 1-5 GeV/c at midrapidity, where next-to-leading-order perturbative quantum chromodynamic (NLO pQCD) calculations well describe the unpolarized cross section. The observed asymmetry is small and is compared to a NLO pQCD calculation with a range of polarized gluon distributions.

Journal Article↗

[Percutaneous correction of acquired aortic stenosis and mitral insufficiency in adults].

Aortic stenosis and mitral regurgitation are the most common valvular diseases in western countries. Surgical treatment, aortic valve replacement or mitral valve repair, is the treatment of choice. Innovative technologies could offer an alternative therapeutic option to the patients with increased operative risk. This article will report the early experience with these promising techniques as presented at the High-Tech 2004 meeting.

Aortic Valve↗

Absence of suppression in particle production at large transverse momentum in sqrt[s(NN)]=200 GeV d+Au collisions.

Transverse momentum spectra of charged hadrons with p(T)<8 GeV/c and neutral pions with p(T)<10 GeV/c have been measured at midrapidity by the PHENIX experiment at BNL RHIC in d+Au collisions at sqrt[s(NN)]=200 GeV. The measured yields are compared to those in p+p collisions at the same sqrt[s(NN)] scaled up by the number of underlying nucleon-nucleon collisions in d+Au. The yield ratio does not show the suppression observed in central Au+Au collisions at RHIC. Instead, there is a small enhancement in the yield of high momentum particles.

Journal Article↗

Measurement of spin-correlation parameters ANN, ASS, and ASL at 2.1 GeV in proton-proton elastic scattering.

At the Cooler Synchrotron COSY/Jülich spin-correlation parameters in elastic proton-proton (pp) scattering have been measured with a 2.11 GeV polarized proton beam and a polarized hydrogen atomic beam target. We report results for A(NN), A(SS), and A(SL) for c.m. scattering angles between 30 degrees and 90 degrees. Our data on A(SS)--the first measurement of this observable above 800 MeV--clearly disagrees with predictions of available pp scattering phase-shift solutions while A(NN) and A(SL) are reproduced reasonably well. We show that in the direct reconstruction of the scattering amplitudes from the body of available pp elastic scattering data at 2.1 GeV the number of possible solutions is considerably reduced.

Journal Article↗

[Percutaneous artificial heart valves: from animal experimentation to the first human implantation in a case of calcified aortic stenosis].

The development of artificial cardiac valves capable of being positioned by catheter has become an important subject for research, with the objective of treating valvular patients who are not operable or at very high surgical risk. We tested an artificial valve implantable by the percutaneous route, consisting of three leaflets of bovine pericardium sutured to the inside of a stainless steel stent, deployable by inflating a balloon. Following laboratory evaluation, this valve was implanted with success in animals, then for the first time in man, in a case of calcified aortic stenosis. The patient, a 57 year old male in cardiogenic shock, had associated multiple non-cardiac pathology and could not be operated on. Implantation was carried out by the trans-septal anterograde route, the only route available due to severe end stage arteritis. The artificial valve was deposited in the centre of the native aortic valve, without obstructing the coronaries nor reaching the mitral valve. The result was spectacular with instantaneous haemodynamic improvement and excellent valvular function confirmed by transoesophageal echocardiography every 15 days after implantation. Non-cardiac complications marred the progress, dominated by aggravation of pre-existing leg ischaemia, necessitating amputation for which the consequences were fatal at 4 months. This case demonstrates that implantation of a cardiac valve by the percutaneous route is possible in calcified aortic stenosis, and that it brings rapid clinical improvement. This technique could in future constitute an important alternative therapeutic approach for selected patients.

Angioplasty, Balloon↗

[Measurement of the mitral area with three-dimensional cardiac echography].

Two dimensional planimetry of mitral stenosis is sometimes difficult due to the complex morphology of the mitral valve. Three dimensional cardiac echography images the projected area of the mitral valve allowing precise planimetry of the orifice. Thirty patients with mitral stenosis were included in this study in order to obtain planimetry of the mitral orifice with two dimensional and three dimensional "freehand" mode transthoracic echocardiography. In 10 patients, the measurements were taken before and after percutaneous commissurotomy. The mitral area measured with three dimensional echography was 1.36+/-0.45 cm2 and 1.39+/-0.43 cm2 in two dimensional mode. The correlation between the 2 methods was good (y=1.01x - 0.08, r=0.92, p<0.001) but three dimensional echocardiography significantly underestimated the two dimensional planimetry by 0.05+/-0.27 cm2 (4+/-20%, p<0.05). The intra- and inter-observer reproducibility of the three dimensional measurements were 0.95 and 0.91 respectively. Three dimensional free-hand mode cardiac echography allows precise measurement of the mitral orifice area in patients with mitral stenosis.

Echocardiography, Three-Dimensional↗

Effect of load alterations on the effective regurgitant orifice area in chronic aortic regurgitation.

OBJECTIVE: To evaluate the load dependence of effective regurgitant orifice area (ROA) in an animal model of chronic aortic regurgitation. METHODS: Eight sheep were studied 10-20 weeks after the surgical creation of aortic regurgitation. After baseline studies, 500 ml of blood, angiotensin II, and nitroprusside were infused sequentially. Electromagnetic flow meters were used as reference standards to determine aortic regurgitation volume. The time-velocity integral was acquired using the continuous wave Doppler method. RESULTS: Baseline aortic regurgitant volume varied from 8 ml (regurgitant fraction 28%) to 29 ml (59%), with a mean (SD) value of 17 (8) ml; mean ROA was 0.15 (0.05) cm2. During angiotensin II infusion, aortic regurgitation volume (20 (8) ml) and mean diastolic aortoventricular pressure gradient (62 (18) mm Hg) increased by 26 (16)% and 48 (64)%, respectively (p < 0.01 for both). ROA did not change (0.16 (0.06) cm(2), p = 0.15). During nitroprusside infusion, aortic regurgitant volume (13 (7) ml, p = 0.05) and diastolic pressure gradient (25 (13) mm Hg, p < 0.05) decreased. ROA did not change (0.15 (0.05) cm2). When analysing 32 stages together, aortic regurgitant volume (r = 0.78, p < 0.01) and regurgitant fraction (r = 0.55, p < 0.01) correlated well with ROA. However, diastolic pressure gradient (r = 0.28) was not significantly correlated with ROA. CONCLUSIONS: In an animal model of chronic aortic regurgitation, ROA did not change with load alterations.

Angiotensin II↗

Two cases of foodborne botulism type E and review of epidemiology in France.

In 1999, two new cases of type E botulism were observed in French hospitals. Since this type of botulism is uncommon in France, the cases prompted a national epidemiological study. Sixteen cases of type E botulism, including the two cases reported here, occurred between 1952 and 1999. The clinical and treatment characteristics of all cases were evaluated, and the results suggest that, despite its rarity, type E botulism should be considered by clinicians in France. Changes in the eating habits of people in France, as in the rest of Europe, with the increased consumption of vacuum-packed fish from endemic areas and decreased consumption of local foodstuffs, could explain the occurrence of the most recent cases.

Adult↗

Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract.

Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

Animals↗

Interaliasing distance of the flow convergence surface for determining mitral regurgitant volume: a validation study in a chronic animal model.

OBJECTIVES: We aimed to validate a new flow convergence (FC) method that eliminated the need to locate the regurgitant orifice and that could be performed semiautomatedly. BACKGROUND: Complex and time-consuming features of previously validated color Doppler methods for determining mitral regurgitant volume (MRV) have prevented their widespread clinical use. METHODS: Thirty-nine different hemodynamic conditions in 12 sheep with surgically created flail leaflets inducing chronic mitral regurgitation were studied with two-dimensional (2D) echocardiography. Color Doppler M-mode images along the centerline of the accelerating flow towards the mitral regurgitation orifice were obtained. The distance between the two first aliasing boundaries (interaliasing distance [IAD]) was measured and the FC radius was mathematically derived according to the continuity equation (R(calc) = IAD/(1 - radicalv(1)/v(2)), v(1) and v(2) being the aliasing velocities). The conventional 2D FC radius was also measured (R(meas)). Mitral regurgitant volume was then calculated according to the FC method using both R(calc) and R(meas). Aortic and mitral electromagnetic (EM) flow probes and meters were balanced against each other to determine the reference standard MRV. RESULTS: Mitral regurgitant volume calculated from R(calc) and R(meas) correlated well with EM-MRV (y = 0.83x + 5.17, r = 0.90 and y = 1.04x + 0.91, r = 0.91, respectively, p < 0.001 for both). However, both methods resulted in slight overestimation of EM-MRV (Delta was 3.3 +/- 2.1 ml for R(calc) and 1.3 +/- 2.3 ml for R(meas)). CONCLUSIONS: Good correlation was observed between MRV derived from R(calc) (IAD method) and EM-MRV, similar to that observed with R(meas) (conventional FC method) and EM-MRV. The R(calc) using the IAD method has an advantage over conventional R(meas) in that it does not require spatial localization of the regurgitant orifice and can be performed semiautomatedly.

Animals↗