PubMed Health⌕ Search

Biomedical subjects

F Baum

Publications and source records attributed to F Baum.

At least 19 recordsLinked to original sources

Digital mammography: current state and future aspects.

The introduction of digital technique in mammography has been the last step in completing the process of digitalization in diagnostic imaging. Meanwhile, some different digital techniques as well as a couple of different digital mammography systems were developed and have already been available for some years. In this review article, the relevant data of key studies are reported, the current status is defined, and perspectives of digital mammography are described.

Breast Neoplasms↗

Predicting the phenylalanine blood concentration from urine analyses. An approach to noninvasive monitoring of patients with phenylketonuria.

The need for regular blood-drawing in the management of chronic metabolic disorders may negatively influence the compliance of patients and their parents; noninvasive analytical procedures could well alleviate this burden. Using data obtained in six adult probands with phenylketonuria, we evaluate the feasibility of noninvasive prediction of phenylalanine blood concentrations from analysis of phenylalanine and creatinine in urine. Cross-validated regression equations correct for the significant inter-individual variation of phenylalanine fractional excretion rates. With sensitive and specific enzymatic assays for phenylalanine and creatinine, the accuracy of this noninvasive procedure may also become clinically satisfactory for the purpose of self-monitoring.

Adult↗

ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism.

AIM: The purpose of this study was to determine the feasibility of echocardiogram (ECG)-gated multi-slice CT angiography (MCTA) in patients with clinical suspicion of acute venous thromboembolism (VTE), to investigate the effect of ECG-gating on cardiac motion artefacts, and to determine the diagnostic reader agreement of ECG-gated MCTA in comparison with conventional MCTA. MATERIALS AND METHODS: Forty-eight consecutive patients were prospectively enrolled and randomly underwent ECG-gated (n=25, group 1) or non-ECG-gated (n=23, group 2) eight-slice pulmonary MCTA. Image data were evaluated by three independent chest radiologists with respect to the presence or absence of emboli at different arterial levels (main, lobar, segmental, and subsegmental arteries), and with regard to cardiac motion artefacts. Statistical tests used to calculate inter-observer agreement were weighted kappa statistics, extended kappa statistics and confidence indices indicating three-reader agreement accuracy. RESULTS: Twenty-seven patients (56.3%) were diagnosed to have pulmonary embolism (13 from group 1, 14 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70% in group 2 versus 13% in group 1, p=0.0001). The overall diagnostic agreement was excellent with both MCTA techniques (three-reader confidence index for all vascular territories: 0.76 and 0.84 for groups 1 and 2, respectively (extended kappa=0.69 and 0.78, respectively); three-reader confidence index for diagnosis of VTE: 0.94 and 0.85 for groups 1 and 2, respectively (extended kappa=0.91 and 0.73, respectively), weighted kappa=0.81-0.83 and 0.92-0.95 for groups 1 and 2, respectively, and did not differ significantly between the two groups. In addition there was no significant difference of inter-observer agreement in either group at any assessed pulmonary arterial level. CONCLUSION: ECG-gated pulmonary MCTA is feasible in patients with clinical suspicion of VTE. However, ECG-gated image acquisition did not influence the diagnostic reader agreement accuracy and inter-observer agreement of MCTA. Hence, it does not appear to be advantageous for the MCTA diagnosis of pulmonary embolism.

Acute Disease↗

[The contribution of different postprocessing methods for multislice spiral CT in acute pulmonary embolism].

PURPOSE: To investigate the value of different postprocessing algorithms for multislice spiral CT (MSCT) in diagnosing acute pulmonary embolism. MATERIALS AND METHODS: Forty-eight patients with suspected pulmonary embolism prospectively underwent MSCT using an 8-slice spiral CT. Using a confidence level on a three-point scale, three radiologists reviewed 2-mm and 5-mm axial slices, 5-mm and 10-mm axial maximum intensity projections (MIP) and 2-mm coronal slices as well as interactively generated multiplanar reformatted images. A subsequent consensus reading of the primary 1.25-mm axial slices served as gold standard. ROC analysis was applied to the various vascular sections. RESULTS: The ROC analysis revealed a higher diagnostic accuracy of the 2-mm axial sections as compared to the 5-mm axial slices (Az = [0.988;0.976] vs. Az = [0.988;0.802]). Coronal and multiplanar reformations also showed excellent diagnostic accuracy (Az = [0.972;0.949] and Az = [0.997;0.951], respectively) and were significantly superior to the 5-mm axial slices through the segmental and subsegmental arteries (p=0.05). MIP showed the weakest diagnostic accuracy (Az = [0.967;0.802] for 5-mm MIP; Az = [0.879;0.781] for 10-mm MIP). CONCLUSION: Thin axial slices as well as coronal and multiplanar reformations are superior to thick axial slices in the diagnosis of acute pulmonary embolism. MIP is not suited for accurate diagnosis of pulmonary embolic disease.

Acute Disease↗

[Diagnostic performance of retrospectively ECG-gated multislice CT of acute pulmonary embolism].

AIM: This study determined the diagnostic performance of ECG-gated MSCT in comparison with conventional MSCT. MATERIALS AND METHODS: Forty-five consecutive patients prospectively underwent ECG-gated (group 1, n = 23) or non-ECG-gated (group 2, n = 22) 8-slice MSCT of the pulmonary arteries. Image data were interactively evaluated by three independent chest radiologists with respect to the presence of emboli at different arterial levels, and with regard to cardiac motion artefacts. Consensus reading by two experienced chest radiologists served as diagnostic gold standard. ROC analysis was carried out for the different vascular sections. RESULTS: Twenty-five patients (56 %) were diagnosed to have pulmonary embolism (13 from group 1, 12 from group 2). Cardiac motion artefacts were significantly more frequent in group 2 (70 % in group 2 versus 13 % in group 1, p < 0.05). There was no significant difference between the two groups in the overall sensitivities (0.92 vs. 0.95) and specificities (0.92 vs. 0.98) or in sensitivities and specificities at any assessed pulmonary arterial level. CONCLUSION: ECG-gated MSCT pulmonary angiography does not significantly influence the diagnostic performance of MSCT in these patients. Therefore no recommendation for routine clinical practice can be given.

Adolescent↗

Computer-aided detection in direct digital full-field mammography: initial results.

For the first time, full-field digital mammography (FFDM) allows computer-aided detection (CAD) analysis of directly acquired digital image data. The purpose of this study was to evaluate a CAD system in patients with histologically correlated breast cancer depicted with FFDM. Sixty-three cases of histologically proven breast cancer detected with FFDM (Senographe 2000D, GE Medical Systems, Buc, France) were analyzed using a CAD system (Image Checker V2.3, R2 Technology, Los Altos, Calif.). Fourteen of these malignancies were characterized as microcalcifications, 37 as masses, and 12 as both. The mammographic findings were categorized as BI-RADS 3 (n=5), BI-RADS 4 (n=17) and BI-RADS 5 (n=40). The sensitivity for malignant lesions and the rate of false-positive marks per image were calculated. The sensitivity and its 95% confidence interval (CI) were estimated. The sensitivity of the CAD R2 system in breast cancer seen on FFDM was 89% for microcalcifications [CI(95%)=(70%; 98%)] and 81% for masses [CI(95%)=(67%; 91%)]. As expected, the detection rate was higher in lesions categorized as BI-RADS 5 (37 of 40) compared with lesions categorized as BI-RADS 4 (11 of 17). In the group categorized as BI-RADS 3 the detection rate was 4 of 5 lesions; however, this group was very small. The rate of false-positive marks was 0.35 microcalcification marks/image and 0.26 mass marks/image. The overall rate of false-positive marks was 0.61 per image. CAD based on FFDM provides an optimized work flow. Results are equivalent to the results reported for CAD analysis of secondarily digitized image data. Sensitivity for microcalcifications is acceptable and for masses is low. The number of false-positive marks per image should be reduced.

Breast Neoplasms↗

Comparative study in patients with microcalcifications: full-field digital mammography vs screen-film mammography.

The goal of this prospective study was to compare a full-field digital mammography system (FFDM) to a conventional screen-film mammography system (SFM) for the detection and characterization of microcalcifications. Fifty-five patients with 57 isolated microcalcification clusters were examined using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, Wis.) and a SFM system (Senographe DMR, GE Medical Systems, Milwaukee, Wis.). A conventional screen-film mammogram and a digital contact mammogram were obtained of each cluster. The image quality and the number of calcification particles were evaluated, and a characterization (BI-RADS 1-5) of microcalcifications was given by four experienced readers. Histopathology revealed 16 benign lesions (sclerosing adenosis, dysplasia, hamartoma, radial scar) in 15 patients and 21 malignant tumors (in situ carcinoma, invasive carcinoma) in 20 patients. Twenty patients had benign changes verified by long-term follow-up. Image quality of FFDM was assessed as superior to SFM in more than 50% of the cases. The FFDM showed more calcifications in 41% of all cases. Sensitivity and specificity for FFDM vs SFM were 95.2 vs 91.9% and 41.4 vs 39.3%, respectively. Moreover, FFDM demonstrated a higher diagnostic accuracy (deviation: 0.86 BI-RADS steps) compared with FSM (deviation 0.93 BI-RADS steps). The FFDM system with a 100- micro m pixel size provides better image quality than SFM in patients with mammographic microcalcifications. The FFDM has a higher sensitivity and a higher reliability in characterizing microcalcifications.

Breast Neoplasms↗

Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions.

The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADS;) [corrected] categories (FFDM better than SFM in 23 of 165 vs 9 of 165 judged cases in SFM). In conclusion, digital mammography offers a consistent, high image quality in combination with a better contrast and without artifacts. Lesion detection in digital images was equal to that in screen-film images; however, categorization of the lesions to the BI-RADS classification was slightly better.

Adult↗

Classification of hypervascularized lesions in CE MR imaging of the breast.

The purpose of this paper is to define and evaluate a classification category for contrast-enhanced (CE) MR imaging of the breast based on the BI-RADS mammographic categories of the American College of Radiology. Using five evaluation criteria for MR findings (initial signal increase, post-initial signal behavior, shape, border, and contrast material distribution within enhancing tumors) 522 patients (1031 breasts) were analyzed. Scores were given from 0 to 8 points and classified into five categories (group I: 0 points, negative; group II: 1-2 points, benign; group III: 3 points, probably benign; group IV: 4-5 points, suspicious abnormality; group V: 6-8 points, highly suspicious for malignancy) to 265 focal hypervascularized breast lesions in 244 breasts (patient group A). These findings were correlated with histology or follow-up. Additionally, this classification was correlated to the contrast medium uptake within the parenchyma of the remaining 787 breasts without any focal lesion (patient group B). Two hundred sixty-five hypervascularized lesions in 238 patients (244 breasts, patient group A) were classified into group I: 0%; group II: 27.3%; group III: 22.3%; group IV: 18.6%; and group V: 31.8%. Histology revealed 115 benign and 134 malignant tumors in these groups. Sixteen benign lesions were controlled by follow-up. Sensitivity for the detection of malignancy using the presented multifactorial MRM classification was 92%, and specificity was 92%. Excluding cases of ductal carcinoma in situ specificity increased to 95%. Seven hundred eighty-seven breasts without any focal hypervascularized lesion (patient group B) were classified into groups I or II. Follow-up ( n=771) or histology ( n=14) confirmed the diagnosis in 785 of these breasts. Histopathology revealed, however, malignant tumors in the remaining two cases. The classification of lesions based on a multifactorial analysis is very helpful in the interpretation of CE MRI of the breast. The evaluation of all diagnostic imaging modalities, however, is essential in determining the correct diagnosis and/or in deciding on the appropriate therapeutic procedure.

Breast↗

[Quality management in a radiology department].

PURPOSE: To increase the quality of internal and external interactions (patients, clinical colleagues, technicians, radiologists) in a department of radiology. METHOD: Accompanied by a well-experienced adviser workshops have been performed dealing with different topics like "contact to patients," "performance of the radiological report and interaction with the referring colleague" or "research and teaching." A catalogue of different actions was defined to reduce hindrances within the internal and external work-flow. RESULTS: A total number of 53 actions was defined and related to different persons who were responsible for the realisation of the measures within a time interval. Six months after starting the quality management 46 (86%) of the defined actions were realised successfully, and another 4 (8%) measures were still running. There was a moderate increase of satisfaction of the patients and clinical colleagues considering the waiting time. CONCLUSIONS: A quality management in a radiological department allows an optimisation of the internal and external interactions. However, the guidance of a well-experienced adviser is as essential as the continuous control of successful finished measures.

Education↗

[Digital full field mammography: comparison between radiographic direct magnification and digital monitor zooming].

PURPOSE: Our goal was to compare digital magnification mammograms with images zoomed from the digital contact mammogram in patients with microcalcifications. PATIENTS AND METHODS: Fifty-five patients with 57 microcalcification clusters were evaluated with a FFDM system (Senographe 2000D, GE). In addition to a digital contact mammogram, a digital direct magnification mammogram (factor 1.8 [MAG1.8]) and an image zoomed from the contact mammogram with a magnification factor of 1.8 [ZOOM1.8] were obtained in each patient. The image quality (perfect = 5 points to inadequate = 1 point) and the characterization of microcalcifications (BI-RADS 2-5) were evaluated by 4 readers. The results were compared to histopathologic findings in 35 patients (37 lesions) and follow-up in 20 patients. RESULTS: Histopathology revealed 16 benign and 21 malignant lesions. 20 patients had benign changes verified by long-term follow-up. Image quality of direct magnification FFDM was assessed superior (4.44 points) to zoomed images (4.14 points). Sensitivity was superior for direct magnification (97.5%) in comparison to the zoomed images (96.3%). However, specificity (MAG1.8: 34.3%, ZOOM1.8: 40%), PPV (MAG1.8: 47.5%, ZOOM1.8: 49.8%) and accuracy (MAG1.8: 58.1%, ZOOM1.8: 61.2%) were better with zooming technique. Deviation steps from best BI-RADS assessment were 0.45 for MAG1.8 and 0.44 for ZOOM1.8. CONCLUSIONS: In patients with mammographic microcalcifications, monitor zooming of the digital contact mammogram is equivalent to direct magnification FFDM. Therefore, monitor zooming allows a reduction of the radiation exposure and an optimization of the work-flow.

Breast Diseases↗

[Indications for percutaneous stereotactic vacuum core biopsy of the breast].

As a consequence of technical improvements and an increased number of investigations in asymptomatic patients, more and more suspicious lesions are being detected in mammography. These lesions can be evaluated using different biopsy techniques. In comparison to open biopsy, stereotactic methods require less costs and time, and reduce morbidity. The introduction of the vacuum core biopsy method allowed the excision of suspicious areas through a single needle insertion. In the current literature, however, the indications for vacuum core biopsy are being discussed controversely. This article includes an introduction of this specific technique, a presentation of the BI-RADS (Breast Imaging Reporting and Data System) categories and an overview of the literature of the indications for use of the vacuum system. The "pros and cons" of vacuum core biopsy will be discussed in comparison with the alternative biopsy methods.

Biopsy↗

Preoperative local MRI-staging of patients with a suspected pancreatic mass.

The aim of this study was to define the value of MRI of the pancreas for preoperative local staging of patients with a suspected pancreatic mass. Ninety-four patients (41 women, 53 men; age range 32-87 years) with a suspected pancreatic tumor underwent preoperative staging with MRI on a 1.5-T system. The MRI protocol included breath-hold MR cholangiopancreatography in turbo spin-echo technique, biphasic contrast-enhanced 3D MR angiography, and MRI of the upper abdomen with breath-hold T2-weighted half-Fourier acquired single-shot turbo spin-echo and T1-weighted fast-low-angle-shot (pre- and postcontrast) sequences. Data were collected prospectively and analyzed by two radiologists in agreement modality. Evaluation criteria were vascular involvement, resectability, and a characterization benign vs malignant. Results were compared to histopathology in 78 patients. Sixteen patients were followed-up. In 74 of 94 patients a solid tumor or an inflammation of the pancreas ( n=62) or the papilla ( n=12) was detected. In this group, MRI had a sensitivity of 98%, a specificity of 92%, and an accuracy of 96% in the characterization of malignant tumors. Regarding only the solid tumors, the positive predictive value of MRI was 87% with respect to resectability. Other pathologic findings included adenoma or inflammation of the duodenum ( n=5), carcinoma or benign stenosis of the choledochus duct ( n=7) and carcinoma of the gall bladder ( n=2). In 6 patients MRI did not depict any pathologic findings, and follow-up confirmed this interpretation. Magnetic resonance imaging allows a local preoperative staging in patients with suspected pancreatic tumor. Limitations, however, concern to the diagnostics of peritoneal and/or liver metastases.

Adult↗

[Value and significance of digital full-field mammography within the scope of mammography screening].

To evaluate the digital technique for screening mammography various experimental studies and clinical examinations were performed by using direct full-field digital mammography (FFDM). The findings concerning the detectability and characterization of microcalcifications and soft tissue masses as well as the radiation exposure were compared to the state-of-the-art conventional screen-film mammography (SFM). The results of these studies revealed a high performance of the digital images, which are at least equivalent to the conventional images, whereas digital spot views were significantly superior to conventional ones particularly in the detection of microcalcifications. This was especially true, when the potential of post-processing was used. In addition, the sensitivity of FFDM should be increased, if computer-aided-diagnosis (CAD) is available. Furthermore, the patient radiation dose can be significantly reduced. Additional advantages are quick and easy handling, efficient data transfer and digital archiving. Thus, FFDM will become an important tool in screening mammography.

Breast Neoplasms↗

[Stereotactic vacuum core biopsy of clustered microcalcifications classified as B1-RADS 3].

PURPOSE: Evaluation of stereotactic vacuum core biopsy of clustered microcalcifications categorized as BI-RADS 3. MATERIAL AND METHODS: 86 patients with microcalcifications BI-RADS 3 (probably benign, < 3% malignant) underwent a stereotactic vacuum core biopsy (Mammotome, Fa. Ethicon Endo-Surgery Breast Care) using a digital stereotactic unit (Mammotest, Fa. Fischer Imaging). The removal of the calcifications was judged by two radiologists in consensus and classified as complete (100%), major (55-99%) or incomplete (< 50%). RESULTS: 4/86 patients could not be evaluated by vacuum core biopsy due to the localization of the microcalcifications close to the skin or lack of detection. In 40/82 cases a complete, in 38/82 a major, and in 4/82 a incomplete removal was achieved. Histology revealed 67 cases of fibrocystic changes, 4 papillomas, 4 fibroadenomas, 4 cases of atypical ductal hyperplasia (ADH), and 3 ductal carcinomas in situ (DCIS), one of these with a minimal-invasive tumor component. Patient with ADH were advised to undergo surgical biopsy. Histology revealed complete removal. 7 patients had complications or side-effects. CONCLUSIONS: Percutaneous vacuum core biopsy is a reliable minimal-invasive diagnostic method to come to the final diagnosis in patients with clustered microcalcifications categorized BI-RADS 3. However, if malignancy is proven (about 4% of our cases) an open biopsy is necessary.

Adult↗

Coping with health care reform.

This paper describes the evaluation of a case study of health service reform in southern Adelaide. A mail survey, interviews and focus groups were used to gain an understanding of health care providers' perceptions and experiences of reform. The paper discusses lessons learnt about health service reform and its impact on people working in the health system. It finds that continual change that is not based on a well-articulated vision is likely to lead to 'reform fatigue' and low morale. An action research approach can be used by researchers to help managers and staff understanding the context in which reform is happening, and thus give support to organisational learning.

Adaptation, Psychological↗

Health promoting hospitals: a typology of different organizational approaches to health promotion.

This paper draws on a review of the literature about the types of health promotion activities conducted by health promoting hospitals and an observation of how some Australian hospitals have structured the organizational arrangements to be more health promoting. This paper also draws on the experiences of one of the authors (A.J.) in managing and evaluating an organizational change process at a major specialist hospital in Adelaide, South Australia, that sought to re-orientate the hospital towards placing more emphasis on health promotion. From these three sources, a typology of four approaches of organizational arrangement to health promotion is presented. These approaches are: 'doing a health promotion project'; 'delegating it to the role of a specific division, department or staff'; 'being a health promotion setting'; and 'being a health promotion setting and improving the health of the community'. For the re-orientation of the specialist hospital to occur and be sustainable, the research indicated that over the case study period of 1994-1998 there had to be strong organizational commitment to change, supported at multiple levels of the organization, and reflected in policy and practice change. The paper concludes that more evaluative research of this type will be important if the rhetoric of healthy settings is to become a reality.

Attitude of Health Personnel↗