PubMed Health⌕ Search

Biomedical subjects

F Bonk

Publications and source records attributed to F Bonk.

4 recordsLinked to original sources

Short-range structure and cation bonding in calcium-aluminum metaphosphate glasses.

Comprehension of short- and medium-range order of phosphate glasses is a topic of interest, due to the close relation between network structure and mechanical, thermal, and optical properties. In this work, the short-range structure of glasses (1 - x)Ca(PO(3))(2).xAl(PO(3))(3) with 0 < or = x < or = 0.47 was studied using solid-state nuclear magnetic resonance spectroscopy, Raman spectroscopy, density measurements, and differential scanning calorimetry. The bonding between a network modifier species, Al, and the network forming phosphate groups was probed using high-resolution nuclear magnetic resonance spectroscopy of (27)Al and (31)P. Changes in the compositional behavior of the density, glass transition temperature, PO(2) symmetric vibrations, and Al coordination number were verified at around x = 0.30. (31)P NMR spectra show the presence of phosphorus in Q(2) sites with nonbridging oxygens (NBOs) coordinated by Ca ions and also Q(2) sites with one NBO coordinated by Al (namely, Q(2)(1Al)). The changes in the properties as a function of x can be understood by considering the mean coordination number measured for Al and the formation of only Q(2) and Q(2)(1Al) species. It is possible to calculate that a network formed only by Q(2)(1Al) phosphates can just exist up to the upper limit of x = 0.48. Above this value, Q(2)(2Al) species should appear, imposing a major reorganization of the network. Above x = 0.30 the network undergoes a progressive reorganization to incorporate Al ions, maintaining the condition that only Q(2)(1Al) species are formed. These observations support the idea that bonding principles for cationic species inferred originally in binary phosphate glasses can also be extended to ternary systems.

Journal Article↗

A composite curve of ultrasonic biparietal diameters for estimating gestational age.

A composite curve of biparietal diameters at various gestational ages was constructed from previous reports from five large centers. Estimates of the mean gestational age using the composite curve compared favorably with other reporting institutions. This suggests that the newly established echography department may employ the composite curve of mean values and need not develop its own biparietal growth curve. The clinical application of these mean values however, should recognize a considerable variance from the mean. These variations represent normal growth differences in the biparietal dimension, errors inherent in the ultrasonic methodology and apparent differences in the populations examined. A method is suggested by which variations from the mean may be identified for each echographic facility.

Cephalometry↗

Prospectively gated cardiac computed tomography.

A fourth-generation scanner has been modified to perform prospectively gated cardiac computed tomography (CT). A computer program monitors the electrocardiogram (ECG) and predicts when to initiate the next scan in a gated series in order to acquire all projection data for a desired phase of the heart cycle. The system has been tested with dogs and has produced cross-sectional images of all phases of the cardiac cycle. Eight to ten scans per series were sufficient to obtain reproducible images of each transverse section in the end-diastolic and end-systolic phases. The radiation dose to the skin was approximately 1.4 cGy per scan. The prospectively gated system is more than twice as efficient as a retrospectively gated system in obtaining complete angular projection data for a 10% heart cycle window. A temporal smoothing technique to suppress reconstruction artifacts due to sorting inconsistent projection data was developed and evaluated. Image noise was reduced by averaging together any overlapping projection data. Prospectively gated cardiac CT has also been used to demonstrate that the error in attenuation measured with a single nongated CT scan through the heart can be as large as 50-60 CT numbers outside the heart in the lung field.

Animals↗