Twenty years' monitoring of Mèze stabilisation ponds: part I--Removal of organic matter and nutrients.

The Mèze stabilisation pond system has been monitored over more than 20 years. Despite the enlargement of the plant, the organic load doubled between the early 1980s and recent years, the removal of organic matter and nutrients has been maintained at the same level for COD and increased for BOD5, N and P. Combining anaerobic, step-fed aerated and maturation ponds and multiplying the number of cells resulted in a significant improvement in the performances of the plant. Respectively 34, 24 and 23% of the applied COD was eliminated in the anaerobic, the step-fed and the first three maturation ponds, while the figures for BOD5 were 47, 26, and 19% respectively. 38% of the applied nitrogen was eliminated in the first three maturation ponds. Nitrification and denitrification seem to be a major process of nitrogen removal in warm periods. Most of the phosphorus removal was observed to take place in the two polishing ponds.

Biodegradation, Environmental↗

Twenty years' monitoring of Mèze stabilisation ponds: part II--Removal of faecal indicators.

The WSP system serving Mèze and Poussan (French Mediterranean coast) was constructed in 1980 and enlarged and upgraded from 1994 to 1998. Water quality along the waste stabilisation pond to (WSP) system has been monitored over the years, thus allowing us to assess the influence of enlargement and upgrading works. A significant enhancement of the average microbiological quality of the effluent was observed, with respective E. coli and streptococci average abatements of 4.1 and 3.4 log. units. Former seasonal variations of microbiological removal have vanished. The contribution of the different ponds to the disinfection performance of the WSP system was analysed. A microbiological quality model was proposed to evaluate the die-off kinetics related to the different ponds and as a tool for the design and management of WSP systems. Though the relationships between die-off coefficients and environmental factors appeared somewhat frail, this modelling is considered a promising approach for the prediction of WSP microbiological performance.

Bacteria↗

Mosquito development and biological control in a macrophyte-based wastewater treatment plant.

A one-year study of the proliferation of mosquito in a Pistia stratiotes-based waste stabilization ponds in Cameroon revealed that Mansonia and Culex were the main breeding genera with about 55% and 42% of the total imagoes respectively. Though the ponds represent a favorable breeding ground for mosquitoes, only 0.02% of captured imagoes was Anopheles gambiae, suggesting that this wastewater treatment plant does not significantly contribute to the development of the malaria vector in the area. Gambusia sp. introduced to control mosquito population in the ponds acclimatized relatively well in most of the ponds (B3-B7) and their feeding rate without any diet ranged from 15.0 to 50.2 larvae/day for a single fish.

Animals↗

Microphyte and macrophyte-based lagooning in tropical regions.

A 720 m2 plant made of 8 ponds in series, set in Yaounde (Cameroon), was successively operated as a macrophyte-based system (type M) from November 1997 to October 98, a microphyte-based system (type m) from October 1999 to September 2000 and a combination of macrophyte and microphyte ponds (type M + m) from May to July 2001. Average applied loads varied over the years; from 420 kg. BOD5 ha(-1)d(-1) on the year 1997/98, the loads reached 510 kg BOD5 ha(-1)d(-1) in 1999/2000 and 500 in 2001. Though the system became more and more overloaded and sludge accumulated rapidly in the first ponds, it provided average removals of SS, BOD5 and COD that were always higher than 90% whatever the type of lagooning. Performances in the removal of SS, organic matter and the abatement of N-NH4+ and PO4(3-) did not significantly differ according to the type of lagooning and the applied load. Macrophyte lagooning did not show any definitive superiority as to nutrient removal when compared to microphyte lagooning. Microphyte lagooning was the most effective process in faecal indicators removal.

Ammonia↗

Setting up microbiological water reuse guidelines for the Mediterranean.

Water reuse is a widespread practice in most Mediterranean countries. Some countries have no wastewater treatment facilities and direct reuse of raw wastewater is occurring while others have a well-established national reuse policy. Water reuse microbiological standards, when existing, significantly differ from one country to another. Some countries have adopted regulations close to the California's Water Recycling Criteria whereas other countries have chosen criteria based on the World Health Organisation (WHO) guidelines. California standards are technologically based requirements aimed at eliminating the presence of pathogens. The WHO guidelines relied on epidemiological evidences though few were available. Their revision on the basis of new epidemiological investigations and quantitative microbiological risk assessment (QMRA) provided by Blumenthal et al., together with added QMRA data, helped proposing Mediterranean guidelines. Acceptable annual risks related to bathing and potable water drinking were taken as benchmarks. This proposal is designed to protect individuals against realistic maximum exposures and to provide minimum and affordable requirements which should constitute the basis of water reuse regulations in every country of the region. Inadequacies of the actual knowledge do not allow a definitive position regarding the guideline limits; other scientific and technical basis are still required.

Conservation of Natural Resources↗

Mixing and its impact on faecal coliform removal in a stabilisation pond.

Faecal coliform removal in stabilisation ponds is highly dependent on shortest water retention times. Tracer tests have been performed in a 3,300 m2 and 1.0 m deep pond, located in Southern France, to measure the retention times and bring light on the main influencing factors and mechanisms. Tracer concentrations were monitored at the outlet and 60 locations within the pond--at the surface, mid depth and the bottom of the water column. Pond water temperatures were measured at different depths and locations, together with pH, DO and redox potential. Wind velocity and rainfall were recorded. Water quality was monitored at the inlet, outlet and within the pond. Water retention times were shown to be strongly affected by weather conditions. Windy periods appeared to favour mixing regardless of the season. In sunny periods of spring and summer, a clear stratification was observed during daytime and vanished gradually during the night, suggesting alternation of mixed and stratified hydrodynamic patterns. This alternation was shown to influence microorganism contents within and at the outlet of the pond. Accurate prediction of shortest water retention times and disinfection performance requires 3D unsteady state fluid dynamic models that are able to take the influence of wind and water temperature distribution into account.

Disinfection↗

Oxidation processes and clogging in intermittent unsaturated infiltration.

Intermittent infiltration of wastewater through a non saturated sand bed is an extensive treatment process aimed at eliminating organic pollution, oxidizing ammonia and removing pathogens. A 1D numerical model, IPOX, has been worked out to simulate the transfer and oxidation of dissolved organic matter and nitrogen in unsaturated sand beds. IPOX was calibrated after real scale tests performed in Spain and Burkina Faso. Simulations allowed us to point out the influence of (i) kinetics on oxidation performances and (ii) biomass development on the process sustainability. These results brought a new light on the sizing and operation of infiltration percolation and soil aquifer treatment (SAT) plants.

Ammonia↗

Non-steady-state modelling of faecal coliform removal in deep tertiary lagoons.

In Noirmoutier, a French island off the Atlantic coast, secondary effluents flow into a series of four lagoons, 1.4-2.8 m deep, and are reused for agricultural irrigation. The excess water is disposed of to the sea. The aim of this study was to provide a model capable of predicting the microbiological quality of the water pumped for irrigation or discharged to the sea. Meteorological variables, flow rates, physical-chemical characteristics and faecal coliform (FC) contents were monitored for a year and a half. The hydraulic pattern of each lagoon was assumed to be that of completely mixed reactor because of the calculated dispersion numbers and the wind mixing effect. Coliform decay was assumed to follow first order kinetics in each lagoon. Die-off coefficients were calculated in each lagoon using a non-steady-state model. The main bacterial removal mechanism was shown to be solar irradiation. Empirical equations were established to calculate die-off coefficients as a function of received solar energy and temperature. FC die-off rates were higher in the first lagoon and then decreased successively in those following. FC numbers in the different lagoons were predicted with reasonable accuracy in spite of high variation in inlet water quality. The model will facilitate the prediction of water quality under various climatic conditions and different water reuse scenarios and will help to optimise reclamation and storage facilities.

Atlantic Ocean↗

[Pollution of the groundwater in the city of Niamey, Niger].

We conducted a study on chemical and bacteriological groundwater pollution in Niamey, a Sahelian city of some 700,000 inhabitants. A total of 22 wells and 24 bore-holes were selected on a geological and socio-economic basis. The superficial aquifers, located on each bank of the River Niger and connected to the wells, presented high levels of oxidizable nitrogen and bacteriological pollution (coliform and faecal Streptococcus) which make the water unfit for human consumption. The deep aquifer, which supplies pumps, was also polluted but to a lesser degree. Faecal pollution increased after the rainy season. The lack of sanitation in Niamey and the seepage of polluted matters from the superficial layers could explain this pollution. Eventually, the use of the groundwater could increase and constitute a major health risk for the majority of the inhabitants of Niamey.

Colony Count, Microbial↗

Use of recycling through medium size granular filters to treat small food processing industry effluents.

Currently there are no suitable wastewater treatment systems for effluents from small food processing industries (dairy, cheese, wine production). Such raw sewages are characterized by high organic matter concentrations (about 10 g COD L-1) and relatively low daily volumes (about 2 m3). An adaptation of attached-growth cultures on fine media processes, known to be easy and inexpensive to use, could fit both the technical and economical context of those industries. Coarser filter particle size distributions than those normally used allow a better aeration and reduce clogging risk. The transit time of the effluent through the porous filter materials is shortened and requires recycling to increase the contact time between the biomass and the substrate. A pilot plant was built to compare the efficiency of two kinds of filter materials, gravel (2-5 mm) and pozzolana (3-7 mm). Two measurement campaigns were undertaken on a full-scale unit dealing with cheese dairy effluents. Both pilot-scale and full-scale plants show high COD removal rates (> 95%). Pilot-scale experiments show that accumulation of organic matter leads to the clogging of the recycling filter. To prevent early clogging, a better definition of feeding cycles is needed.

Conservation of Natural Resources↗

Modelling of a recirculating granular medium filter's processes.

The effluents of French small farm factories will soon be submitted to regulation. Only a few treatment techniques are available to deal with these kind of effluent (high concentration and small daily volumes). To allow the treatment, in the particular economic context of small food processing industries, Cemagref is trying to adapt a treatment based on attached growth cultures on fine media, a system known to be easy to operate and relatively inexpensive. A model, based on four sub-models (hydrodynamic characteristics, oxygen transport, solute transport in the mobile and immobile phases and bacterial evolution) describes this process. Based on wastewater concentration, hydraulic load, applied organic loads, feeding/rest cycles and recycling phases number, this model predicts: eliminated organic loads and the discharge concentration as a function of time, oxygen and biomass contents as a function of time and depth. The determination of the model's parameters is based on a comparison between simulations and performances achieved on experimental columns. This model would be helpful in sizing full-scale filters treating different types of agro-food wastewater. The aim of this article is to present the model's structure, to give all parameter values and to compare the simulations with the results obtained on pilot and full scale plants.

Agriculture↗

Design of a climate-dependent water reuse project.

Reclaimed water storage is imperative in water reuse management. Climate is a primary factor controlling reclaimed water storage design by its significant influence on irrigation water needs as well as on stored water quality. This study presents a modelling approach that has been applied to assist the design of a climate-dependent water reuse project on an Atlantic island. Models for predicting irrigation water needs and water quality in tertiary lagoons were coupled with a technical-economic model to design reclaimed water storage facilities. Three scenarios corresponding to different augmentation of current reclaimed water reuse were investigated. According to the modelling, the storage sizes to meet the water quantity required for irrigation increased with water deficit--the difference between evapotranspiration and precipitation. The size of tertiary lagoons to meet required water quality was found to be larger than the size to meet required water quantity. To meet both quantitative irrigation needs and <1,000 FC/100 ml irrigation and disposal regulation, extending the tertiary lagoon system would be more cost-effective than storage calculated to meet only quantitative irrigation needs supplemented with UV disinfection. The reliability of reclaimed water storage design was estimated with 40 years historic climatic records.

Climate↗

Reuse of reclaimed wastewater for golf course irrigation in Tunisia.

In Tunisia, golf courses are irrigated with secondary treated effluent stored in landscape impoundments. The impact of the conveyance and storage steps on the physical-chemical and biological quality of irrigation water was evaluated on three golf courses over two years. It was found that the water quality varies all along the water route, from the wastewater treatment plant up to the irrigation site: nutrient and bacteria contents decreased along the route in the three cases. This variation depends on the wastewater quality, the length of the pipes conveying water, the number of regulation reservoirs and ponds, the water residence time in pipes, reservoirs and ponds, and the operation of the ponds. The bacteriological quality of irrigation water deteriorates during the irrigation period in the three golf courses as the ponds are operated as continuous flow reactors. The results obtained in this study indicate the inability of golf water supplies, as currently managed, to properly sanitize reclaimed wastewater and meet target quality criteria recommended by WHO (1989) for water intended for recreational use. For a safe reuse of reclaimed wastewater for golf course irrigation, changes in the design and operation of the ponds should be planned or additional treatment steps provided.

Conservation of Natural Resources↗

Role of water reuse for enhancing integrated water management in Europe and Mediterranean countries.

Recycling water is an important aspect of water resource and environment management policies, ensuring reliable alternative water resources, reducing environmental pollution and achieving a more sustainable form of development. This paper focuses on wastewater reuse as a strategy for integrated water management. Key economic, financial, regulatory, social and technical factors that help to make water reuse projects successful are reviewed. Selected examples from Northern and Western Europe and arid and semi-arid Mediterranean regions illustrate the contribution of wastewater reuse to integrated management of water resources.

City Planning↗

Technical-economic modelling of integrated water management: wastewater reuse in a French island.

An integrated technical-economic model is used to address water management issues in the French island of Noirmoutier. The model simulates potable water production and supply, potable and non potable water demand and consumption, wastewater collection, treatment and disposal, water storage, transportation and reuse. A variety of water management scenarios is assessed through technical, economic and environmental evaluation. The scenarios include wastewater reclamation and reuse for agricultural and landscape irrigation as well as domestic non potable application, desalination of seawater and brackish groundwater for potable water supply. The study shows that, in Noirmoutier, wastewater reclamation and reuse for crop irrigation is the most cost-effective solution to the lack of water resources and the protection of sensitive environment. Some water management projects which are regarded as having less economic benefit in the short-term may become competitive in the future, as a result of tightened environmental policy, changed public attitudes and advanced water treatment technologies. The model provides an appropriate tool for water resources planning and management.

Agriculture↗