Nasal cannula and transtracheal oxygen delivery. A comparison of patient response after 6 months of each technique.

The purpose of this study was to compare the efficacy of transtracheal (TT) oxygen delivery to that of nasal cannula delivery in subjects with chronic obstructive pulmonary disease (COPD). Twenty subjects (14 men, 6 women) were followed for 6 months during nasal cannula delivery. A TT catheter was then inserted, and measurements were repeated during TT use. With TT delivery, subjects required 45% less oxygen at rest and 39% less during exercise (p less than 0.0001). Oxygen use, measured by pounds of oxygen delivered to the home, also decreased, but the magnitude of change was less than anticipated (mean, 14%; range, +4% to -32%). Hospital days decreased from 12 +/- 10 during nasal cannula use to 4 +/- 6 during TT use (p less than 0.002). Exercise tolerance, as measured by a 12-min walk distance, was greater during TT use (p less than 0.0001). No change was seen in spirometry or acid-base balance. Also, no change was seen in Profile of Mood States, Sickness Impact Profile or Katz Adjustment Scale scores. Some problems were encountered relating to use of the catheter (displacement, mucus balls), but they were minor, and most were confined to the initial 2 months of TT use when the tract was immature. Our experience suggests that, in addition to decreasing oxygen flow rate, use of TT delivery may confer benefits that result in improved exercise tolerance and decreased hospitalization in patients with COPD.

Catheterization

Pulmonary function abnormalities in chronic severe cardiomyopathy preceding cardiac transplantation.

Pulmonary function data, including diffusing capacity, were evaluated in 56 patients with chronic severe cardiomyopathy before heart transplantation. Cardiac catheterization data were used to describe the relationship between cardiac and pulmonary function. Of 56 patients 44 had some abnormality in pulmonary function. The majority, 30 of 56, had a restrictive impairment alone. Of 28 patients in whom diffusing capacity was measured, 64% had a diffusion impairment. There was no association of pulmonary function impairment with type of cardiomyopathy or smoking history. Pulmonary capillary wedge pressure correlated positively with DLCO, but not with FVC or TLC. Cardiac index and ejection fraction did not correlate with diffusing capacity. This precardiac transplantation cardiomyopathy patient group demonstrated frequent pulmonary function abnormalities not previously recognized.

Adult

The use of a short-length transtracheal oxygen catheter in patients of small stature with restrictive lung disease.

Transtracheal oxygen therapy is being used with increasing frequency because it is an effective mode of oxygen delivery and is well tolerated by patients. An increase in cough and mild intermittent hemoptysis are not uncommon in the early postinsertion period but usually resolve spontaneously. Herein we present two individuals of short stature with restrictive lung disease who had persistence of excessive cough and mild hemoptysis after insertion of a standard catheter (SCOOP). Bronchoscopic evaluation in one revealed erosions of the mucosa over the carina and take-off of the right main-stem bronchus. Symptoms resolved in both individuals following placement of a shorter catheter. We suggest that greater consideration be given to matching transtracheal catheter length to patient lung size, particularly in the face of severe restrictive lung disease.

Adult

The effect of obliterative bronchiolitis on breathing pattern during exercise in recipients of heart-lung transplants.

The more rapid and shallow ventilation pattern seen during exercise in patients with obstructive and/or restrictive lung disease has been attributed by some investigators to the effects of vagal afferents from intrapulmonary receptors. Recipients of heart-lung transplants (HLTR) offer a unique opportunity to test this hypothesis since they have denervated lungs and may develop obliterative bronchiolitis after organ rejection. We thus compared the ventilation responses to incremental bicycle ergometry of five HLTR with relatively normal pulmonary function (HLTR-N) and four with bronchiolitis obliterans (HLTR-O). We compared the slopes of the linear portion of the tidal volume versus inspired minute ventilation relationship of both groups. The rate of rise of tidal volume (VT) (slope of VT versus VI) was greater in HLTR-N (0.31 +/- 0.004) than in HLTR-O (0.023 +/- 0.007) (p less than 0.05). This corresponded to a slower increase in respiratory rate (RR) (slope of RR versus Vl/cm) in HLTR-N (0.055 +/- 0.005) than in HLTR-O (0.083 +/- 0.019) (p less than 0.01). Furthermore, values for VT, inspiratory time (TI), and duty cycle (TI/Ttot) measured during exercise at the VT break point were all significantly lower in the HLTR-O than in HLTR-N. We also evaluated the ability of HLTR with lung disease to regulate their ultimate level of ventilation during maximal exercise.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Transtracheal delivery of oxygen: efficacy and safety for long-term continuous therapy.

Transtracheal (TT) oxygen delivery involves administration of oxygen percutaneously through a catheter inserted in the suprasternal trachea. Transtracheal oxygen delivery has been proposed as a means of overcoming the high visibility, inconvenience, and discomfort associated with nasal cannula use. This report describes our experience using TT delivery in 40 patients with chronic obstructive pulmonary disease (n = 32) and other types of lung disease (n = 8). Overall acceptance of TT catheter use was high and only 5 subjects elected to discontinue use. We believe the TT route is a relatively safe approach for oxygen administration and a promising method of improving patient compliance. It also offers the potential of more adequately oxygenating patients with refractory hypoxemia.

Adult

Inductance plethysmography measurement of CPAP-induced changes in end-expiratory lung volume.

The respiratory inductance plethysmograph (RIP) has recently gained popularity in both the research and clinical arenas for measuring tidal volume (VT) and changes in functional residual capacity (delta FRC). It is important however, to define the likelihood that individual RIP measurements of VT and delta FRC would be acceptably accurate (+/- 10%) for clinical and investigational purposes in spontaneously breathing individuals on continuous positive airway pressure (CPAP). Additionally, RIP accuracy has not been compared in these regards after calibration by two commonly employed techniques, the least squares (LSQ) and the quantitative diagnostic calibration (QDC) methods. We compared RIP with pneumotachographic (PTH) measurements of delta FRC and VT during spontaneous mouth breathing on 0-10 cmH2O CPAP. Comparisons were made after RIP calibration with both the LSQ (6 subjects) and QDC (7 subjects) methods. Measurements of delta FRC by RIPLSQ and RIPQDC were highly correlated with PTH measurements (r = 0.94 +/- 0.04 and r = 0.98 +/- 0.01 (SE), respectively). However, only an average of 30% of RIPQDC determinations per subject and 31.4% of RIPLSQ determinations per subject were accurate to +/- 10% of PTH values. An average of 55.2% (QDC) and 68.8% (LSQ) of VT determinations per subject were accurate to +/- 10% of PTH values. We conclude that in normal subjects, over a large number of determinations, RIP values for delta FRC and VT at elevated end-expiratory lung volume correlate well with PTH values. However, regardless of whether QDC or LSQ calibration is used, only about one-third of individual RIP determinations of delta FRC and one-half of two-thirds of VT measurements will be sufficiently accurate for clinical and investigational use.

Functional Residual Capacity

Exercise tolerance during nasal cannula and transtracheal oxygen delivery.

Previous studies have reported that exercise tolerance improves with transtracheal oxygen delivery. However, patients were not blinded to the delivery technique used, introducing a potential source of bias. The purpose of this study was to compare exercise tolerance during nasal cannula and transtracheal delivery using a randomized double-blinded technique. Subjects (n = 11) performed 12-min walks on the same day while receiving nasal cannula and transtracheal delivery. Nine of 11 subjects walked farther with transtracheal delivery, a significant increase (p less than 0.01). Mean increase in walk distance was 95 +/- 86 feet. In addition, a trend was seen toward greater improvement in walk distance with greater flows through the catheter (r = 0.58, p less than 0.06). Time into the walk when desaturation (SaO2 less than 90%) first occurred was not significantly different. We conclude that exercise tolerance improves when oxygen is delivered by transtracheal catheter. This improvement is unrelated to an increase in SaO2. We speculate that the increase in exercise tolerance may be related to other physiologic effects of flow through the catheter.

Aged

Giant-cell interstitial pneumonia and hard-metal pneumoconiosis. A clinicopathologic study of four cases and review of the literature.

We report four cases of giant-cell interstitial pneumonia that occurred in association with exposure to hard metals. All patients presented with chronic interstitial lung disease and had open-lung biopsies that revealed marked interstitial fibrosis, cellular interstitial infiltrates, and prominent intraalveolar macrophages as well as giant cells displaying cellular cannibalism. We also review the literature to determine the sensitivity and specificity of giant-cell interstitial pneumonia for hard-metal pneumoconiosis. Although hard-metal pneumoconiosis may take the form of usual interstitial pneumonia, desquamative interstitial pneumonia, and giant-cell interstitial pneumonia, the finding of giant-cell interstitial pneumonia is almost pathognomonic of hard-metal disease and should provoke an investigation of occupational exposure.

Adult

Ventilation and breathing pattern during progressive hypercapnia and hypoxia after human heart-lung transplantation.

The effects of human pulmonary denervation on the ventilatory responses to progressive hyperoxic hypercapnia and isocapnic hypoxia as well as the effect on resting breathing pattern were evaluated in nine female heart-lung transplant (H-LT) recipients. The results were compared to those obtained from 10 normal women of comparable age and stature. Testing was performed 2 to 37 months after H-LT (median, 7.5 months). Cardiac function was normal in all H-LT recipients. None of the patients had spirometric evidence of airway obstruction, while six had a restrictive pattern with forced vital capacities less than 80% of predicted values. Resting minute ventilation (VE), tidal volume (VT), and ventilatory drive (VT/TI) in the H-LT recipients were not significantly different from those of the normal subjects. Inspiratory time (TI), however, was significantly shorter in the H-LT patients (1.64 +/- 0.2 versus 2.09 +/- 0.13 s, p = 0.035), and resting breathing frequency (F) tended to be greater in the H-LT recipients (16.27 +/- 2.04 versus 12.82 +/- 0.53 breaths/min, p = 0.052). The overall ventilatory response to hypercapnia was reduced after H-LT (0.91 +/- 0.17 versus 1.5 +/- 0.27 L/min/mm Hg CO2, p less than 0.043), as was the F response (0.2 +/- 0.09 versus 0.65 +/- 0.13 breaths/min/mm Hg CO2, p less than 0.01). The VT and VT/TI responses to hypercapnia did not differ between the H-LT recipients and normal subjects. There were no significant differences between the two groups with respect to the responses to progressive hypoxia.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Breathing during wakefulness and sleep after human heart-lung transplantation.

To study the effects of pulmonary denervation on breathing during sleep, sleep studies were conducted on seven heart-lung transplant recipients (H-LT) and a comparable number of sex-matched normal subjects of similar age. Four of the H-LT patients had a restrictive pattern on spirometry. The time since transplantation ranged from 45 to 1,102 days. There were no significant differences between the groups with respect to total sleep time or distribution of sleep stages. There were no significant differences between the H-LT recipients and normal subjects with respect to baseline awake oxyhemoglobin saturation (SaO2) or the nadirs of SaO2 during REM and non-REM sleep, the absolute number and frequency (number per hour of sleep) of apneas, hypopneas, desaturation events, both over the whole night of study or separately during non-REM and REM sleep. Across wakefulness and all sleep stages, the H-LT patients tended to have shorter total respiratory cycle times (Ttot) (p = 0.052) and more rapid breathing frequency (F) than the normal subjects. This was associated with significantly shorter inspiratory times (Tl) (p less than 0.001) and smaller duty cycles (Tl/Ttot) (p less than 0.005) in the H-LT recipients. During non-REM and REM sleep, F tended to be higher in the H-LT recipients with pulmonary restriction than in the nonrestricted patients. There were no significant differences between the H-LT recipients and the normal subjects with regard to the periodicity of breathing, either in terms of timing parameters or breath amplitude.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Evidence of an altered pattern of breathing during exercise in recipients of heart-lung transplants.

Recipients of heart-lung transplants represent an unusual opportunity to study the regulation of ventilation, because the neural pathways between the lungs and the central nervous system are disrupted in these patients. We compared the ventilation response in seven recipients of heart-lung transplants who had normal pulmonary function and seven recipients of heart transplants, all of whom performed incremental bicycle ergometry. The level of ventilation in recipients of heart-lung transplants was similar to that in heart-transplant recipients for equivalent levels of carbon dioxide production. Arterial pH and partial pressure of carbon dioxide at maximal exercise were normal and not significantly different in the two groups, also suggesting that levels of ventilation were appropriate in both groups. However, the rate of the rise in respiratory rate for increasing levels of ventilation was significantly lower in recipients of heart-lung transplants than in heart-transplant recipients, and the initial increase in tidal volume was more rapid in the former group than in the latter. Thus, recipients of heart-lung transplants have an appropriate level of ventilation during exercise as the result of a disproportionate increase in tidal volume at a reduced respiratory rate. We speculate that intrapulmonary receptors are important in regulating the pattern, but not the absolute level, of ventilation during exercise.

Acid-Base Equilibrium

Comparison of arm and leg ergometry in patients with moderate chronic obstructive lung disease.

Exercise testing is traditionally performed with leg exercise on either a treadmill or a bicycle ergometer. Many of these tests are terminated before dyspnoea occurs because of leg fatigue, arthritic pain, or claudication. A study was carried out to determine whether arm ergometry testing might serve as an alternative method to leg testing in eight patients with chronic obstructive lung disease. The patients had mild to moderate dyspnoea on exertion and required bronchodilator treatment. They had smoked an average of 62 pack years and had a mean FEV1 of 1.88 l. Arm and leg ergometry yielded similar levels of maximum ventilation (arm 47.2, leg 48.6 l/min), maximum heart rates (126 v 124 beats/min), maximum tidal volume (1.5 v 1.6 l), and respiratory rate (30 v 29 breaths/min); but maximum oxygen consumption (1120 v 966 ml/min), maximum power output (62 v 26 w), and oxygen pulse (9.1 v 7.8 ml/beat) were all higher with leg than with arm ergometry. In addition, ventilation and heart rate at a given level of oxygen consumption were higher for arm than for leg work during both submaximal and maximal exercise. It is concluded that arm ergometry offers an alternative testing method to leg testing in patients with moderate chronic obstructive lung disease.

Arm

DLco in COPD.

Explore the source record for details and available documents.