PubMed Health⌕ Search

Biomedical subjects

F Calamante

Publications and source records attributed to F Calamante.

At least 19 recordsLinked to original sources

A rigorous framework for diffusion tensor calculus.

In biological tissue, all eigenvalues of the diffusion tensor are assumed to be positive. Calculations in diffusion tensor MRI generally do not take into account this positive definiteness property of the tensor. Here, the space of positive definite tensors is used to construct a framework for diffusion tensor analysis. The method defines a distance function between a pair of tensors and the associated shortest path (geodesic) joining them. From this distance a method for computing tensor means, a new measure of anisotropy, and a method for tensor interpolation are derived. The method is illustrated using simulated and in vivo data.

Anisotropy↗

Anisotropic noise propagation in diffusion tensor MRI sampling schemes.

The subject of this study is the controversial choice of directions in diffusion tensor MRI (DT-MRI); specifically, the numerical algebra related to this choice. In DT-MRI, apparent diffusivities are sampled in six or more directions and a least-squares equation is solved to reconstruct the diffusion tensor. Numerical characteristics of the system are considered, in particular the condition number and normal matrix, and are shown to be dependent on the relative orientation of the tensor with respect to the laboratory frame. As a consequence, noise propagation can be anisotropic. However, the class of icosahedral direction schemes is an exception, and icosahedral directions have the same condition number and normal matrix for direction encoding as the ideal scheme with an infinite number of directions. This normal matrix and its condition number are rotationally invariant. Numerical simulations show that for icosahedral schemes with 30 directions the standard deviation of the fractional anisotropy is both low and nearly independent of fiber orientation. The recommended choice of directions for a DT-MRI experiment is therefore the icosahedral set of directions with the highest number of directions achievable in the available time.

Anisotropy↗

Limitations and requirements of diffusion tensor fiber tracking: an assessment using simulations.

Diffusion tensor fiber tracking potentially can give information about in vivo brain connectivity. However, this technique is difficult to validate due to the lack of a gold standard. Fiber tracking reliability will depend on the quality of the data and on the robustness of the algorithms used. Information about the effects of various anatomical and image acquisition parameters on fiber tracking reliability may be used in the design of imaging sequences and of tracking algorithms. In this study, tracking was performed on two different simulated models to study the effects on tracking quality of SNR, anisotropy, curvature, fiber cross-section, background anisotropy, step size, and interpolation. Tracking was also performed on volunteer data to assess the relevance of the simulations to real data. Our results show that, in general, tracking with high SNR and high anisotropy using interpolation and a low step size gives the most reliable results. Partial volume effects are shown to have a detrimental effect when the background is anisotropic and when tracking narrow fibers. The results derived from real data show similar trends and thus support the findings of the simulations. These simulations may therefore help to determine which structures can be tracked for a given image quality.

Algorithms↗

Quantification of perfusion using bolus tracking magnetic resonance imaging in stroke: assumptions, limitations, and potential implications for clinical use.

BACKGROUND: MR techniques have been very powerful in providing indicators of tissue perfusion, particularly in studies of cerebral ischemia. There is considerable interest in performing absolute perfusion measurements, with the aim of improving the characterization of tissue "at risk" of stroke. However, some important caveats relating to absolute measurements need to be taken into account. The purpose of this article is to discuss some of the issues involved and the potential implications for absolute cerebral blood flow measurements in clinical use. SUMMARY OF COMMENT: In bolus tracking MRI, deconvolution of the concentration-time course can in theory provide accurate quantification. However, there are several important assumptions in the tracer kinetic model used, some of which may be invalid in cerebral ischemia. These can introduce significant errors in perfusion quantification. CONCLUSIONS: Although we believe that bolus tracking MRI is a powerful technique for the evaluation of perfusion in cerebral ischemia, interpretation of perfusion maps requires caution; this is particularly true when absolute quantification is attempted. Work is currently under way in a number of centers to address these problems, and with appropriate modeling they may be overcome in the future. In the interim, we believe that it is necessary for users of bolus tracking perfusion data to be aware of the current technical limitations if they are to avoid misinterpretation or overinterpretation of their findings.

Cerebrovascular Circulation↗

MR perfusion imaging in Moyamoya Syndrome: potential implications for clinical evaluation of occlusive cerebrovascular disease.

BACKGROUND AND PURPOSE: Ischemic symptoms in patients with moyamoya syndrome (MMS) are usually due to hemodynamically mediated perfusion failure, and identification of abnormal tissue perfusion in these patients is therefore clinically important. Although dynamic susceptibility contrast (DSC) MRI can be used to study tissue perfusion, there are potential technical problems in MMS. This study investigates the scope and limitations of perfusion MRI in the clinical evaluation of such patients. METHODS: Thirteen patients with bilateral MMS were studied with the use of structural, diffusion, and perfusion MRI. The DSC MRI data were analyzed both visually and by a quantitative regional analysis, and the relationship between perfusion status and clinical symptoms was investigated. RESULTS: Extensive bilateral DSC MRI abnormalities were observed in all the patients. There was a very heterogeneous distribution of bolus arrival time. The areas of abnormality included the major arterial border zones in all cases, although these usually appeared normal on structural and diffusion MRI. Only the most clinically unstable patients had peak width (defined as time to peak minus bolus arrival time) >5 seconds on the quantitative regional analysis. Several technical limitations of perfusion quantification in MMS are described, as well as the implications of these limitations in patients with other forms of occlusive large-vessel disease. CONCLUSIONS: The technical limitations of DSC MRI described in this study are important for the accurate interpretation of perfusion MRI in MMS. Despite these limitations, these preliminary findings suggest that the use of quantitative regional analysis of summary parameters may provide clinically useful information in patients with MMS.

Adolescent↗

Simultaneous noninvasive measurement of CBF and CBV using double-echo FAIR (DEFAIR).

A new method for measuring cerebral blood flow (CBF) and cerebral blood volume (CBV) noninvasively using MRI is presented. The approach is based on the technique of arterial spin labelling (ASL), in which CBF-based contrast is generated by controlled modulation of the longitudinal magnetization of the blood. The proposed method also uses differences in T(2) between tissue and blood to differentiate the two compartments and allow assessment of the relative size of each. Two successive EPI images are acquired following spin preparation using either a slice-selective or global inversion pulse, and the technique is therefore referred to as double-echo FAIR (DEFAIR). DEFAIR is demonstrated in the normal gerbil brain and during hypothermia, where reductions of both CBF and CBV are known to occur. It is also shown theoretically that this method can be extended to include a measurement of oxygen extraction fraction. The main drawbacks of the technique are the long acquisition time and relatively low sensitivity to hemodynamic changes compared to conventional qualitative T2(*)-weighted BOLD contrast, which may limit its applicability and practical use in monitoring functional cerebral activation. However, the technique can be used repetitively in longer-term time course studies due to its noninvasive and quantitative nature.

Animals↗

Perfusion magnetic resonance abnormalities in patients with sickle cell disease.

Neurological complications are common in sickle cell disease (SCD). However, it is often difficult to relate the clinical presentation to conventional neuroimaging, because subclinical infarction is common and stroke has been described in the absence of large-vessel disease. We studied 48 patients with SCD aged 4-34 (median 13) years with T2-weighted, diffusion and perfusion magnetic resonance imaging (MRI) and with MR angiography. Forty-four underwent transcranial Doppler (TCD). Abnormalities on perfusion imaging were seen in 25 cases, 24 of whom had been symptomatic. The remaining patient had evidence of executive dysfunction and reduced perfusion in the frontal lobes. The perfusion abnormality was larger than the area of infarction in 9 patients and was seen in an arterial distribution with no infarction in a further 9. In 3 patients with transient ischemic attacks, perfusion abnormalities were demonstrated in the absence of any other neuroimaging abnormalities, and perfusion changes were seen in 3 others despite normal MR angiography and TCD. Perfusion abnormalities are associated with neurological symptoms in patients with SCD, whether or not MRI, MR angiography, and TCD are abnormal. It is likely that this technique will guide management in individual patients.

Adolescent↗

Sampling and reconstruction effects due to motion in diffusion-weighted interleaved echo planar imaging.

Subject motion during diffusion-weighted interleaved echo-planar imaging causes k-space offsets which lead to irregular sampling in the phase-encode direction. For each image, the k-space shifts are monitored using 2D navigator echoes, and are shown to lead to a frequent violation of the Nyquist condition when an ungated sequence is used on seven subjects. Combining data from four repeat acquisitions allows the Nyquist condition to be satisfied in all but 1% of images. Reconstruction of the irregularly-sampled data can be performed using a matrix inversion technique. The repeated acquisitions make the inversion more stable and additionally improve the signal-to-noise ratio. The resultant isotropic diffusion-weighted images and average apparent diffusion coefficient (ADC) maps show high resolution and enable clear localization of a stroke lesion. Residual ADC artifacts with a slow spatial variation are observed and assumed to originate from non-rigid pulsatile brain motion. Magn Reson Med 44:101-109, 2000.

Artifacts↗

Delay and dispersion effects in dynamic susceptibility contrast MRI: simulations using singular value decomposition.

Dynamic susceptibility contrast (DSC) MRI is now increasingly used for measuring perfusion in many different applications. The quantification of DSC data requires the measurement of the arterial input function (AIF) and the deconvolution of the tissue concentration time curve. One of the most accepted deconvolution methods is the use of singular value decomposition (SVD). Simulations were performed to evaluate the effects on DSC quantification of the presence of delay and dispersion in the estimated AIF. Both delay and dispersion were found to introduce significant underestimation of cerebral blood flow (CBF) and overestimation of mean transit time (MTT). While the error introduced by the delay can be corrected by using the information of the arrival time of the bolus, the correction for the dispersion is less straightforward and requires a model for the vasculature.

Adult↗

Acute changes in MRI diffusion, perfusion, T(1), and T(2) in a rat model of oligemia produced by partial occlusion of the middle cerebral artery.

Oligemic regions, in which the cerebral blood flow is reduced without impaired energy metabolism, have the potential to evolve toward infarction and remain a target for therapy. The aim of this study was to investigate this oligemic region using various MRI parameters in a rat model of focal oligemia. This model has been designed specifically for remote-controlled occlusion from outside an MRI scanner. Wistar rats underwent remote partial MCAO using an undersize 0.2 mm nylon monofilament with a bullet-shaped tip. Cerebral blood flow (CBF(ASL)), using an arterial spin labeling technique, the apparent diffusion coefficient of water (ADC), and the relaxation times T(1) and T(2) were acquired using an 8.5 T vertical magnet. Following occlusion there was a decrease in CBF(ASL) to 35 +/- 5% of baseline throughout the middle cerebral artery territory. During the entire period of the study there were no observed changes in the ADC. On occlusion, T(2) rapidly decreased in both cortex and basal ganglia and then normalized to the preocclusion values. T(1) values rapidly increased (within approximately 7 min) on occlusion. In conclusion, this study demonstrates the feasibility of partially occluding the middle cerebral artery to produce a large area of oligemia within the MRI scanner. In this region of oligemic flow we detect a rapid increase in T(1) and decrease in T(2). These changes occur before the onset of vasogenic edema. We attribute the acute change in T(2) to increased amounts of deoxyhemoglobin; the mechanisms underlying the change in T(1) require further investigation.

Animals↗

The measurement of diffusion and perfusion in biological systems using magnetic resonance imaging.

The aim of this review is to describe two recent developments in the use of magnetic resonance imaging (MRI) in the study of biological systems: diffusion and perfusion MRI. Diffusion MRI measures the molecular mobility of water in tissue, while perfusion MRI measures the rate at which blood is delivered to tissue. Therefore, both these techniques measure quantities which have direct physiological relevance. It is shown that diffusion in biological systems is a complex phenomenon, influenced directly by tissue microstructure, and that its measurement can provide a large amount of information about the organization of this structure in normal and diseased tissue. Perfusion reflects the delivery of essential nutrients to tissue, and so is directly related to its status. The concepts behind the techniques are explained, and the theoretical models that are used to convert MRI data to quantitative physical parameters are outlined. Examples of current applications of diffusion and perfusion MRI are given. In particular, the use of the techniques to study the pathophysiology of cerebral ischaemia/stroke is described. It is hoped that the biophysical insights provided by this approach will help to define the mechanisms of cell damage and allow evaluation of therapies aimed at reducing this damage.

Animals↗

Diffusion and perfusion magnetic resonance imaging in childhood stroke.

Two magnetic resonance imaging techniques, diffusion and perfusion imaging, are being used increasingly for evaluation of pathophysiology of stroke. This article introduces these techniques and reports some initial studies using these approaches, together with conventional T2-weighted magnetic resonance imaging, for investigation of childhood stroke. It is shown that the combination of T2-weighted and diffusion images can provide information about the timing of stroke events in childhood, and perfusion imaging can detect abnormalities not visible by other magnetic resonance imaging techniques. These magnetic resonance methods therefore should play an important role in investigation of children with stroke and could be of particular value in studies of at-risk populations of children such as those with sickle cell disease.

Adolescent↗

Correction for eddy current induced Bo shifts in diffusion-weighted echo-planar imaging.

The importance of diffusion-weighted MRI in the assessment of acute stroke is well-recognized, and quantitative maps of the apparent diffusion coefficient (ADC) are now widely used. Echoplanar imaging provides a robust method of acquiring diffusion-weighted images free of motion artifact. However, initial experience with clinical MRI systems indicates that calculation of artifact-free ADC maps from a series of echo-planar diffusion-weighted images is not necessarily straight-forward. One of the problems is that frequency shifts resulting from eddy currents can cause misregistration of base diffusion-weighted images. In this study, an on-line correction method that overcomes this problem is described, and phantom and human images that demonstrate the validity of the technique are presented. The method uses a non-phase-encoded reference scan to correct the phase of each echo in the echo train, and can provide ADC maps that are free of misregistration artifacts, without the need for off-line postprocessing.

Anisotropy↗

Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose difficulties, the combined perfusion and diffusion data nevertheless distinguish between a "moderately affected area," with reduced perfusion but normal diffusion; and a "severely affected area," in which both perfusion and diffusion are significantly reduced. Two novel magnetic resonance imaging observations are reported, namely, a decrease in T2 and an increase in T1, both within the first few minutes of ischemia. The rapid initial decrease in T2 is believed to be associated with an increase in deoxyhemoglobin levels, while the initial increase in T1 may be related to several factors, such as flow effects, an alteration in tissue oxygenation, and changes in water environment.

Animals↗

Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies.

Flow-sensitive alternating inversion recovery (FAIR) is a pulsed arterial spin labeling magnetic resonance imaging method for perfusion quantification. In its standard implementation for quantification with full longitudinal relaxation between acquisitions, its use in time-course investigations of rapidly changing flow values is limited. The time efficiency can be improved by decreasing the repetition time but quantification becomes problematic. This situation is further complicated if a whole-body radiofrequency transmit coil is not used since fresh blood spins will flow in from outside the coil. To alleviate these problems, the use of global pre-saturation is proposed. The resulting expression for the flow signal depends on the relationship between the imaging parameters and the coil inflow time and can be significantly simplified under certain combinations of these parameters. With this implementation of FAIR, quantitative flow maps of gerbil brains were obtained with a 3 minute time resolution in a study of the effects of reperfusion. The pre-occlusion flow measurements were in good agreement with values obtained by the standard FAIR implementation and by other techniques, but the low values following occlusion were underestimated due to the increased transit times.

Animals↗

The effect of residual Nyquist ghost in quantitative echo-planar diffusion imaging.

Single-shot diffusion-weighted echo-planar imaging (EPI) is typically used for most clinical diffusion studies due to its low sensitivity to patient motion. Although the Nyquist ghost artifact in EPI can be substantially reduced, there is frequently a residual ghost with low signal intensity. As reported in this study, this residual ghost can produce severe artifacts when maps of the apparent diffusion coefficient (ADC) are calculated from single-shot echo-planar images. The artifacts presented in this paper appear as regions of apparently low ADC which simulate regions of reduced diffusion, but are in fact generated by b-value dependent Nyquist ghosts of the orbits. Data acquired in vivo were used to demonstrate that these artifacts can be avoided by including standard methods of spatial presaturation or fluid-suppression in the diffusion-weighted EPI protocol. In addition, phantom studies were used to illustrate how phase and amplitude variations in the ghost generate the artifacts and theoretical expressions, derived elsewhere, were used to provide a detailed understanding of the artifacts observed in vivo. The level of Nyquist ghost reported for the current generation of commercial scanners suggests that this is a general phenomenon which should be a consideration in all EPI-based diffusion studies. Magn Reson Med 42:385-392, 1999.

Artifacts↗

Measuring cerebral blood flow using magnetic resonance imaging techniques.

Magnetic resonance imaging techniques measuring CBF have developed rapidly in the last decade, resulting in a wide range of available methods. The most successful approaches are based either on dynamic tracking of a bolus of a paramagnetic contrast agent (dynamic susceptibility contrast) or on arterial spin labeling. This review discusses their principles, possible pitfalls, and potential for absolute quantification and outlines clinical and neuroscientific applications.

Animals↗

Reperfusion in a gerbil model of forebrain ischemia using serial magnetic resonance FAIR perfusion imaging.

BACKGROUND AND PURPOSE: Existing methods for the quantitative measurement of the changing cerebral blood flow (CBF) during reperfusion suffer from poor spatial or temporal resolution. The aim of this study was to implement a recently developed MRI technique for quantitative perfusion imaging in a gerbil model of reperfusion. Flow-sensitive alternating inversion recovery (FAIR) is a noninvasive procedure that uses blood water as an endogenous tracer. METHODS: Bilateral forebrain ischemia of 4 minutes' duration was induced in gerbils (n=8). A modified version of FAIR with improved time efficiency was used to provide CBF maps with a time resolution of 2.8 minutes after recirculation had been initiated. Quantitative diffusion imaging was also performed at intervals during the reperfusion period. RESULTS: On initiating recirculation after the transient period of ischemia, the FAIR measurements demonstrated either a symmetrical, bilateral pattern of flow impairment (n=4) or an immediate side-to-side difference that became apparent with respect to the cerebral hemispheres in the imaged slice (n=4). The flow in each hemisphere displayed a pattern of recovery close to the preocclusion level or, alternatively, returned to a lower level before displaying a delayed hypoperfusion and a subsequent slow recovery. The diffusion measurements during this latter response suggested the development of cell swelling during the reperfusion phase in the striatum. CONCLUSIONS: The CBF during the reperfusion period was monitored with a high time resolution, noninvasive method. This study demonstrates the utility of MRI techniques in following blood flow changes and their pathophysiological consequences.

Animals↗