PubMed Health⌕ Search

Biomedical subjects

F Carducci

Publications and source records attributed to F Carducci.

30 records · Page 2Linked to original sources

High-resolution electro-encephalogram: source estimates of Laplacian-transformed somatosensory-evoked potentials using a realistic subject head model constructed from magnetic resonance images.

A novel high-resolution electro-encephalographic (EEG) procedure is proposed, including high spatial sampling (128 channels), a realistic magnetic resonance-constructed subject head model, a multi-dipole cortical source model and regularised weighted minimum-norm linear inverse source estimation (WMN). As an innovation, EEG potentials (two healthy subjects; median-nerve, short-latency somatosensory-evoked potentials (SEPs)) are preliminarily Laplacian-transformed (LT) to remove brain electrical activity generated by subcortical sources (i.e. not represented in the source model). LT-WMN estimates are mathematically evaluated by figures of merit (WMN estimates as a reference). Results show higher dipole identifiability (0.69; 0.088), lower dipole localisation error (0.6 mm; 7.8 mm) and lower spatial dispersion (8.6 mm; 24 mm) in LT-WMN than in WMN estimates (Bonferroni corrected p < 0.001). These estimates are presented on the subject modelled cortical surface to highlight the increased spatial information content in LT-WMN compared with WMN estimates. The proposed high-resolution EEG technique is useful for the study of somatosensory functions in basic research and clinical applications.

Electroencephalography↗

Integration of high resolution EEG and functional magnetic resonance in the study of human movement-related potentials.

Cortical sources of human movement-related potentials (i.e. unilateral finger extension) were modeled using functional magnetic resonance imaging (fMR) data as a constraint of a linear inverse source estimation from highly sampled (128 channels) EEG data. Remarkably, this estimation was performed within realistic subject's MR-constructed head models by boundary element techniques. An appropriate figure of merit served to set the optimal amount of fMR constraints. With respect to standard linear inverse source estimates, fMR-constrained ones presented increased spatial detail and provided a more reliable timing of activation in bilateral sensorimotor cortical regions of interest.

Adult↗

"Gating" of human short-latency somatosensory evoked cortical responses during execution of movement. A high resolution electroencephalography study.

The present study aimed at investigating gating of median nerve somatosensory evoked cortical responses (SECRs), estimated during executed continuous complex ipsilateral and contralateral sequential finger movements. SECRs were modeled with an advanced high resolution electroencephalography technology that dramatically improved spatial details of the scalp recorded somatosensory evoked potentials. Integration with magnetic resonance brain images allowed us to localize different SECRs within cortical areas. The working hypothesis was that the gating effects were time varying and could differently influence SECRs. Maximum statistically significant (p<0. 01) time-varying gating (magnitude reduction) of the short-latency SECRs modeled in the contralateral primary motor and somatosensory and supplementary motor areas was computed during the executed ipsilateral movement. The gating effects were stronger on the modeled SECRs peaking 30-45 ms (N30-P30, N32, P45-N45) than 20-26 ms (P20-N20, P22, N26) post-stimulus. Furthermore, the modeled SECRs peaking 30 ms post-stimulus (N30-P30) were significantly increased in magnitude during the executed contralateral movement. These results may delineate a distributed cortical sensorimotor system responsible for the gating effects on SECRs. This system would be able to modulate activity of SECR generators, based on the integration of afferent somatosensory inputs from the stimulated nerve with outputs related to the movement execution.

Adult↗

Bilateral neuromagnetic activation of human primary sensorimotor cortex in preparation and execution of unilateral voluntary finger movements.

Extracranial magnetoencephalographic activity was separately recorded (25 channels) from bilateral primary sensorimotor cortex (M1-S1) of normal right-handers during unilateral finger movements. Standard dipole analysis indicated only a contralateral M1-S1 source for first movement-evoked field (MEF1) peaking at about 115 ms after electromyographic onset. However, the subtraction of the magnetic field generated by this source from the recorded magnetic field disclosed a low-amplitude ipsilateral central-parietal MEF1 that was explained by an ipsilateral M1-S1 source.

Adult↗

Human movement-related potentials vs desynchronization of EEG alpha rhythm: a high-resolution EEG study.

Movement-related potentials (MRPs) and event-related desynchronization (ERD) of alpha rhythm were investigated with an advanced high-resolution electroencephalographic technology (128 channels, surface Laplacian estimate, realistic head modeling). The working hypothesis was that MRPs and alpha ERD reflect different aspects of sensorimotor cortical processes. Both MRPs and alpha ERD modeled the responses of primary sensorimotor (M1-S1), supplementary motor (SMA), and posterior parietal (PP, area 5) areas during the preparation and execution of unilateral finger movements. Maximum responses were modeled in the contralateral M1-S1 during both preparation and execution of the movement. The SMA and PP responses were modeled mainly from the MRPs and alpha ERD, respectively. The modeled ipsilateral M1-S1 responses were larger and stronger in the alpha ERD than MRPs. These results may suggest that alpha ERD reflects changes in the background oscillatory activity in wide cortical sensorimotor areas, whereas MRPs represent mainly increased, task-specific responses of SMA and contralateral M1-S1.

Adult↗

Improved realistic Laplacian estimate of highly-sampled EEG potentials by regularization techniques.

In this study we investigated the effects of lambda correction, generalized cross-validation (GCV), and Tikhonov regularization techniques on the realistic Laplacian (RL) estimate of highly-sampled (128 channels) simulated and actual EEG potential distributions. The simulated EEG potential distributions were mathematically generated over a 3-shell spherical head model (analytic potential distributions). Noise was added to the analytic potential distributions to mimic EEG noise. The magnitude of the noise was 20, 40 and 80% that of the analytic potential distributions. Performance of the regularization techniques was evaluated by computing the root mean square error (RMSE) between regularized RL estimates and analytic surface Laplacian solutions. The actual EEG data were human movement-related and short-latency somatosensory-evoked potentials. The RL of these potentials was estimated over a realistically-shaped, magnetic resonance-constructed model of the subject's scalp surface. The RL estimate of the simulated potential distributions was improved with all the regularization techniques. However, the lambda correction and Tikhonov regularization techniques provided more precise Laplacian solutions than the GCV computation (P < 0.05); they also improved better than the GCV computation the spatial detail of the movement-related and short-latency somatosensory-evoked potential distributions. For both simulated and actual EEG potential distributions the Tikhonov and lambda correction techniques provided nearly equal Laplacian solutions, but the former offered the advantage that no preliminary simulation was required to regularize the RL estimate of the actual EEG data.

Adult↗

Responses of human primary sensorimotor and supplementary motor areas to internally triggered unilateral and simultaneous bilateral one-digit movements. A high-resolution EEG study.

We modelled the responses of human primary sensorimotor areas and supplementary motor area to simple, self-initiated unilateral and simultaneous bilateral middle finger movements using a novel high-resolution electroencephalography technology. The results support the view that these cortical motor areas are involved in parallel and present similar activity in the preparation, initiation, and execution of the contralateral and bilateral movements. Furthermore, the left primary sensorimotor area (dominant hemisphere) appears to be activated more than the right primary sensorimotor area during the preparation and performance of the ipsilateral movements.

Adult↗

A high resolution EEG method based on the correction of the surface Laplacian estimate for the subject's variable scalp thickness.

To improve the spatial resolution of human event-related potentials, we developed a new high resolution EEG method based on the improved estimate of the realistic surface Laplacian (SL). The novelty of this method consisted in the computation of the local scalp resistance that was assumed to be inversely proportional to the local scalp thickness measured from magnetic resonance images of the subject's head. The local scalp thickness was then multiplied by the SL estimate of the potential over a realistic magnetic resonance-constructed model of the subject's scalp surface. The new method was applied on human movement-related and somatosensory-evoked potentials, the SL estimate at a constant scalp thickness being used as a reference. The locally-predicted scalp thickness was significantly (P < 0.05) higher in the temporal areas (9.5 +/- 2.6 mm) than in the parieto-occipital (6.6 +/- 1.3 mm) and frontal (4.8 +/- 1.1 mm) areas. Compared to the SL estimate at constant scalp thickness, the improved SL estimate enhanced the spatial detail of both movement-related and somatosensory-evoked potentials.

Brain Mapping↗

High resolution EEG: a new model-dependent spatial deblurring method using a realistically-shaped MR-constructed subject's head model.

This paper presents a new model-dependent method for the spatial deblurring of scalp-recorded EEG potentials based on boundary-element and cortical imaging techniques. This model-dependent spatial deblurring (MDSD) method used MR images for the reconstruction of the subject's head model, and a layer of 364 radially-oriented equivalent current dipoles as a source model. The validation of the MDSD method was performed on simulated potential distributions generated from equivalent dipoles oriented radially, obliquely, and tangentially to the head surface. Furthermore, this method was used to localize neocortical sources of human movement-related and somatosensory-evoked potentials. It was shown that the new MDSD method improved markedly the spatial resolution of the simulated surface potentials and scalp-recorded event-related potentials. The spatial information content of the scalp-recorded EEG potentials increased progressively by increasing the spatial sampling from 28 to 128 channels. These results indicate that the new method could be satisfactorily used for high resolution EEG studies.

Brain↗

[Endocranial complications of acute and chronic otitis media in children and adolescents].

BACKGROUND: After introduction of antibiotics endocranial complications in otitis media are less common, but there are still diagnostic and therapeutic problems. PATIENTS: 124 patients (5 months-16 years) underwent mastoidectomy. The number, type and therapy of otitic complications is presented. RESULTS: Nine percent of the patients showed up with endocranial complications. Besides lateral sinus thrombosis (five patients), meningitis (five patients) and epidural abscess (five patients), one cerebral and one cerebellar abscess was found. Four patients developed more than one complication. THERAPY: A complete mastoidectomy was performed with exploration of the dura and punction of the lateral sinus. In several cases these procedures gave the first diagnostic hint for endocranial complications. CONCLUSION: The occurrence of endocranial complications in the era of antibiotics should not be underestimated. Cholesteatoma is still a main risk factor for severe complications. If there is any doubt, further imaging studies (CT, MRI) are necessary. Diagnosis and therapy makes a close cooperation between neurosurgeon and ear surgeon and other specialties mandatory.

Acute Disease↗

Spline Laplacian estimate of EEG potentials over a realistic magnetic resonance-constructed scalp surface model.

This paper presents a realistic Laplacian (RL) estimator based on a tensorial formulation of the surface Laplacian (SL) that uses the 2-D thin plate spline function to obtain a mathematical description of a realistic scalp surface. Because of this tensorial formulation, the RL does not need an orthogonal reference frame placed on the realistic scalp surface. In simulation experiments the RL was estimated with an increasing number of "electrodes" (up to 256) on a mathematical scalp model, the analytic Laplacian being used as a reference. Second and third order spherical spline Laplacian estimates were examined for comparison. Noise of increasing magnitude and spatial frequency was added to the simulated potential distributions. Movement-related potentials and somatosensory evoked potentials sampled with 128 electrodes were used to estimate the RL on a realistically shaped, MR-constructed model of the subject's scalp surface. The RL was also estimated on a mathematical spherical scalp model computed from the real scalp surface. Simulation experiments showed that the performances of the RL estimator were similar to those of the second and third order spherical spline Laplacians. Furthermore, the information content of scalp-recorded potentials was clearly better when the RL estimator computed the SL of the potential on an MR-constructed scalp surface model.

Brain Mapping↗

Performances of surface Laplacian estimators: a study of simulated and real scalp potential distributions.

This paper presents a study of the performance of various local and spherical spline methods currently in use for the surface Laplacian (SL) estimate of scalp potential distributions. The SL was estimated from simulated instantaneous event-related scalp potentials generated over a three-shell spherical head model. Laplacian estimators used planar and spherical scalp models. Noise of increasing magnitude and spatial frequency was added to the potential distributions in order to simulate noise presumed to contaminate scalp-recorded event-related potentials. A comparison of noise effects on various Laplacian estimates was made for increasing number of "electrode" positions in variants of the 10-20 system. Furthermore, to evaluate the error due to the use of unrealistic scalp models, the matching between SL estimates of human scalp-recorded movement-related potentials computed on spherical and realistically-shaped MRI-constructed models of the scalp was examined. With all methods the error of the SL estimate increased proportionally with the magnitude and spatial frequency of noise. Increased number of "electrodes" up to 256 significantly reduced the error (p < 0.05). In general, the best SL estimates were computed by second and third order splines including lambda correction, the performances of the second order spline being better with more than 64 "electrodes". Compared with spline Laplacians, the best local methods provided nearly equal estimates with low spatial sampling (19 and 28 "electrodes"), as well as high spatial frequency noise. The error of the SL estimate due to unrealistic scalp model was significant, and it augmented with increased spatial sampling from 64 to 128 electrodes.

Brain↗