PubMed Health⌕ Search

Biomedical subjects

F Casanova

Publications and source records attributed to F Casanova.

At least 19 recordsLinked to original sources

Multiecho sequence for velocity imaging in inhomogeneous rf fields.

The unambiguous determination of velocities with spatial resolution in a multiecho PFG NMR sequence strongly depends on the homogeneity of the B1 field. This affects, in particular, the use of surface coils that bear considerable potential for on-line flow monitoring where a fast-imaging sequence can become vital. However, even with most rf coils dedicated for imaging applications, B1 inhomogeneities are sufficiently large to generate severe problems in performing velocity-imaging experiments. In this paper, the use of a combination of different phase cycles in Carr-Purcell sequences is discussed. The suggested phase cycling scheme tolerates large flip angle imperfections arising in inhomogeneous B1 fields, and thus allows acquisition of a maximum number of echoes within a pulse train. The performance of the velocity-imaging sequence is proven by using phantom samples developing known laminar flow patterns.

Journal Article↗

Preliminary evidence for cachexia in patients with well-established ankylosing spondylitis.

OBJECTIVES: Cachexia, defined as an accelerated loss of skeletal muscle in the context of a chronic inflammatory response, is common in rheumatoid arthritis but it has not been demonstrated in patients with ankylosing spondylitis (AS). The aim of this study was to determine muscle wasting and its functional consequences in a group of patients with well-established AS. METHODS: Nineteen male patients (mean age 53 yrs) with long-standing AS (mean disease duration 19 yrs) and radiological changes (84% had one or more syndesmophytes) were compared with 19 age-matched healthy males with similar levels of habitual physical activity. Body composition was assessed by dual energy X-ray absorptiometry. Muscle strength was measured by isokinetic knee extension and hand grip dynamometry, and by 30 s arm curl and chair sit-to-stand tests. RESULTS: AS patients showed a statistically and clinically significant 12% reduction in arms and legs lean mass, a proxy measure of total body skeletal muscle mass, compared with healthy controls (P < 0.05). This muscle loss was significantly associated with reduced upper and lower body strength (correlation coefficients ranging between 0.37 and 0.79, P < 0.05). CONCLUSION: These results provide preliminary evidence that cachexia is a functionally relevant systemic complication of AS, particularly in patients with long-standing disease and radiological changes. Progressive resistance training and other interventions aimed at stimulating skeletal muscle growth might be beneficial in this population, and further studies on the pathophysiology of cachexia in AS patients are needed.

Absorptiometry, Photon↗

Single-sided sensor for high-resolution NMR spectroscopy.

The unavoidable spatial inhomogeneity of the static magnetic field generated by open sensors has precluded their use for high-resolution NMR spectroscopy. In fact, this application was deemed impossible because these field variations are usually orders of magnitude larger than those created by the microscopic structure of the molecules to be detected. Recently, chemical shift resolved NMR spectra were observed for the first time outside a portable single-sided magnet by implementing a method that exploits inhomogeneities in the rf field designed to reproduce variations of the static magnetic field. In this communication, we describe in detail the magnet system built from permanent magnets as well as the rf coil geometry used to compensate the static field variations.

Journal Article↗

Self-diffusion measurements by a mobile single-sided NMR sensor with improved magnetic field gradient.

A simple and fast method of measuring self-diffusion coefficients of protonated systems with a mobile single-sided NMR sensor is discussed. The NMR sensor uses a magnet geometry that generates a highly flat sensitive volume where a strong and highly uniform static magnetic field gradient is defined. Self-diffusion coefficients were measured by Hahn- and stimulated echoes detected in the presence of the uniform magnetic field gradient of the static field. To improve the sensitivity of these experiments, a Carr-Purcell-Meiboom-Gill pulse sequence was applied after the main diffusion-encoding period. By adding the echo train the experimental time was strongly shortened, allowing the measurement of complete diffusion curves in less than 1min. This method has been tested by measuring the self-diffusion coefficients D of various organic solvents and poly(dimethylsiloxane) samples with different molar masses. Diffusion coefficients were also measured for n-hexane absorbed at saturation in natural rubber with different cross-link densities. The results show a dependence on the concentration that is in good agreement with the theoretical prediction. Moreover, the stimulated-echo sequence was successfully used to measure the diffusion coefficient as a function of the evolution time in systems with restricted diffusion. This type of experiment proves the pore geometry and gives access to the surface-to-volume ratio. It was applied to measure the diffusion of water in sandstones and sheep Achilles tendon. Thanks to the strong static gradient G(0), all diffusion coefficients could be measured without having to account for relaxation during the pulse sequence.

Achilles Tendon↗

Velocity imaging by ex situ NMR.

A pulsed field gradient stimulated spin-echo NMR sequence is combined with imaging methods to spatially resolve velocity distributions and to measure 2D velocity maps ex situ. The implementation of these techniques in open sensors provides a powerful non-invasive tool to measure molecular displacement in a large number of applications inaccessible to conventional closed magnets. The method is implemented on an open tomograph that provides 3D spatial localization by combining slice selection in the presence of a uniform static magnetic field gradient along the depth direction with pulsed field gradients along the two lateral directions. Different pipe geometries are used to demonstrate that the sequence performs well even in the extremely inhomogeneous B0 and B1 fields of these sensors.

Journal Article↗

Profiles with microscopic resolution by single-sided NMR.

A single-sided NMR sensor to produce depth profiles with microscopic spatial resolution is presented. It uses a novel permanent magnet geometry that generates a highly flat sensitive volume parallel to the scanner surface. By repositioning the sensitive slice across the object one-dimensional profiles of the sample structure can be produced with a space resolution better than 5 microm. The open geometry of the sensor results in a powerful testing tool to characterize arbitrarily sized objects in a non-destructive way.

Journal Article↗

Effect of inhaled combination therapy on asthma management.

The growing use of guidelines to manage asthmatic patients prompted us to evaluate their impact on clinical practice. This study was performed in two similar groups of asthmatic patients. A retrospective and prospective review of medical records in an asthmatic population was performed. The patients were followed up for a mean period of 2 years before (group 1 [G1]) and after the publication of the Guideline for Asthma Treatment (group 2 [G2]). After evaluation of objective/clinical measurements we noticed a significant difference between both groups. There were 23 and 40 patients who did not complain of any respiratory symptoms in G1 and G2, respectively. The total number of visits to the emergency department decreased by more than 75%, from 26 (G1) to six (G2). The forced expiratory volume in 1 sec improved by a mean of 4% in G1 and 9% in G2. After application of the guidelines there was a redistribution of the degree of disease severity. In G2, there was a 12% increase in the use of long-acting beta2-stimulating sprays; 40% of the patients were using a combination of a long-acting beta2-stimulating drug and an inhaled steroid. In our experience, the use of the Global Initiative for Asthma (GINA) guidelines leads to better management of asthma patients with different degrees of severity. These findings suggest the need to perform a similar analysis in a broader setting such as a national multicenter survey in order to collect information on the challenges of putting these theoretical difficulties into practice and to compare their implementation in distinct centers.

Administration, Inhalation↗

Cardiovascular responses to aerobic step dance sessions with and without appendicular overload.

AIM: Several studies showed that exercise intensity during aerobic step dance can be modified varying stepping rate, bench height and manipulating body mass using hand held or adding loads to the torso. The aim of this study was to determine the cardiovascular responses during aerobic step dance using an overload strategy not yet investigated: appendicular overload. METHODS: Ten healthy and moderately trained women (mean+/-SD: age 27+/-3.4 years, height 167.8+/-4.6 cm, body mass 55.7+/-4.7 kg, body mass index 19.8+/-1.6, VO2max44.4+/-6.1 mLxkg-1xmin-1) performed an incremental treadmill test to determine VO2peak, the VO2-heart rate (HR) and rating of perceived exertion (RPE)-HR relationships. Within 1 week from the laboratory test, the subjects performed two identical aerobic step dance routines: one using a track suit with loads placed in pockets close to the legs and arms and another without overload. RESULTS: The appendicular overload (10% of body mass) significantly increased the exercise intensity from 84.5% to 89.8% of HRmax corresponding to 68.9% and 78.3% of VO2peak, respectively (P<0.01). Similarly, RPE increased from 12.1 to 15.7 (P<0.001). The estimated VO2 and the caloric expenditure rose from 30.3 to 34.7 mLxkg-1xmin-1 and from 251 to 288 kcal, respectively. CONCLUSION: This study shows that the use of appendicular overload significantly increases the energy cost of aerobic step session similarly to other overload strategies already reported in the literature.

Adult↗

Multi-echo imaging in highly inhomogeneous magnetic fields.

A new pulsed field gradient multi-echo imaging technique to encode position in the phase of every echo generated by a CPMG sequence in the presence of a strongly inhomogeneous static magnetic field is presented. It was applied to improve the sensitivity in an imaging experiment by adding the echo train acquired during the CPMG sequence and to spatially resolve relaxation times of inhomogeneous specimens using single-sided probes. The sequence was implemented in a new bar-magnet MOUSE equipped with a gradient coil system to apply a pulsed magnetic field with a constant gradient along one spatial coordinate. An important reduction by a factor larger than two orders of magnitude in the acquisition time was obtained compared to the previously published single-point imaging technique.

Algorithms↗

3D imaging with a single-sided sensor: an open tomograph.

An open tomograph to image volume regions near the surface of large objects is described. The central achievement in getting such a tomograph to work is the design of a fast two-dimensional pure phase encoding imaging method to produce a cross-sectional image in the presence of highly inhomogeneous fields. The method takes advantage of the multi-echo acquisition in a Carr-Purcell-Meiboom-Gill (CPMG)-like sequence to significantly reduce the experimental time to obtain a 2D image or to spatially resolve relaxation times across the sensitive volume in a single imaging experiment. Depending on T(2) the imaging time can be reduced by a factor of up to two orders of magnitude compared to the one needed by the single-echo imaging technique. The complete echo train decay has been also used to produce T(2) contrast in the images and to spatially resolve the T(2) distribution of an inhomogeneous object, showing that variations of structural properties like the cross-link density of rubber samples can be distinguished by this method. The sequence has been implemented on a single-sided sensor equipped with an optimized magnet geometry and a suitable gradient coil system that provides two perpendicular pulsed gradient fields. The static magnetic field defines flat planes of constant frequency parallel to the surface of the scanner that can be selected by retuning the probe frequency to achieve slice selection into the object. Combining the slice selection obtained under the presence of the static gradient of the open magnet with the two perpendicular pulsed gradient fields, 3D spatial resolution is obtained.

Equipment Design↗

Velocity distributions remotely measured with a single-sided NMR sensor.

The pulsed field gradient nuclear magnetic resonance (PFG NMR) method has proved to be a powerful non-invasive technique to measure molecular displacement in various systems. It has been largely implemented with conventional NMR magnets where the volume for housing the flow setup is restricted. In this work we present the first approach to measure velocity distributions ex situ implementing a pulsed field gradient sequence on a single-sided NMR sensor. The open geometry of these sensors provides access to NMR measurements of a large number of applications previously excluded by the geometry of conventional closed magnets. Both, the distortions to the displacement encoding observed when implementing a PFG sequence in the presence of strongly inhomogeneous B0 and B1 fields, and the performance of the modifications proposed to eliminate these distortions are shown by means of numerical simulations. An alternating stimulated spin-echo PFG sequence implemented to remotely measure velocity distributions was combined with a multi-echo acquisition scheme to significantly increase the sensitivity of the method. The technique was implemented to measure the velocity propagator in a fluid undergoing laminar flow and good agreement with the theoretical result is observed.

Journal Article↗

Echo-planar rotating-frame imaging.

A new rotating-frame imaging method that produces a complete cross section of an object in a single experiment is reported. The echo planar rotating frame imaging (EPROFI) technique uses two perpendicular RF gradients for two-dimensional spatial encoding and fully exploits the formation of rotary echoes for fast sampling of spatial frequencies. The acquisition scheme yields the Fourier transform of the spin distribution on Cartesian coordinates for straightforward image reconstruction. Implementation of the technique on a low-field portable NMR probe is described and results are presented for test objects with different geometries.

Echo-Planar Imaging↗

Two-dimensional imaging with a single-sided NMR probe.

A new low field unilateral NMR sensor equipped with a two-dimensional gradient coil system was built. A new NMR-MOUSE concept using a simple bar magnet instead of the classical U-shaped geometry was used to produce magnetic field profiles comparatively homogeneous in extended lateral planes defining a suitable field of view for 2D spatial localization. Slice selection along the depth direction is obtained by means of the highly constant static magnetic field gradient produced by this magnet geometry. Implementing a two-dimensional phase-encoding imaging method 2D cross sections of objects were obtained with high spatial resolution. By retuning the probe it was possible to change the depth of the selected slice obtaining a 3D imaging method. The details of the construction of the new device are presented together with imaging tests to show the quality of space encoding.

Equipment Design↗

Effect of inhaled bronchodilators on inspiratory capacity and dyspnoea at rest in COPD.

It has been shown that patients with chronic obstructive pulmonary disease (COPD) develop dynamic hyperinflation (DH), which contributes to dyspnoea and exercise intolerance. Formoterol, salmeterol and oxitropium have been recommended for maintenance therapy in COPD patients, but their effect on DH has only been assessed for salmeterol. The aim of the present study was to compare the acute effect of four inhaled bronchodilators (salbutamol, formoterol, salmeterol and oxitropium) and placebo on forced expiratory volume in one second, inspiratory capacity, forced vital capacity and dyspnoea in COPD patients. A cross-over, randomised, double-blind, placebo-controlled study was carried out on 20 COPD patients. Patients underwent pulmonary function testing and dyspnoea evaluation, in basal condition and 5, 15, 30, 60 and 120 min after bronchodilator or placebo administration. The results indicate that in chronic obstructive pulmonary disease patients with decreased baseline inspiratory capacity, there was a much greater increase of inspiratory capacity after bronchodilator administration, which correlated closely with the improvement of dyspnoea sensation at rest. For all bronchodilators used, inspiratory capacity reversibility should be tested at 30 min following the bronchodilator. On average, formoterol elicited the greatest increase in inspiratory capacity than the other bronchodilators used, though the difference was significant only with salmeterol and oxitropium. The potential advantage of formoterol needs to be tested in a larger patient population.

Administration, Inhalation↗

Bronchodilating effect of oxitropium bromide in heart disease patients with exacerbations of COPD: double-blind, randomized, controlled study.

Anti-cholinergic agents are considered the bronchodilator therapy of first-choice in the treatment of patients with stable chronic obstructive pulmonary disease (COPD) associated with heart disease since they may be as effective or more effective than inhaled beta2-agonists and, moreover, they do not interact with cardiac beta-adrenoceptors. The aim of our study was to evaluate the bronchodilator activity of oxitropium bromide in outpatients suffering from exacerbations of COPD associated with heart diseases (ischaemic heart disease and/or arrhythmias). We recruited 50 consecutive outpatients (33 males and 17 females, mean age 68.6 years, 15 current smokers and 35 ex-smokers). Each patient performed body plethismography in basal condition and 30 min after inhalation of 200 microg metered dose inhaler (MDI) oxitropium bromide administered by a device (Fluspacer). FEV1, FVC, MMEF25-75, sRaw and tRaw were evaluated. Thirty minutes after 200 microg oxitropium bromide administration, we observed a significant improvement in FEV1 11.6% +/- 1 (mean +/- SEM) (P<0.01); FVC, MMEF25-75 sRaw variation was respectively: 9.2% +/- 0.6, 31.4 +/- 2.9, -19.9 +/- 1.1. Placebo did not significantly change pulmonary function. Our data suggest that oxitropium bromide bronchodilator activity is effective in exacerbations of COPD.

Acute Disease↗

Solid state proton imaging detected by quadrupole resonance.

A double resonance method for imaging of solid materials containing quadrupole nuclei via the coupled protons is reported. The technique uses a static field gradient to encode the position on the protons and the method of double resonance spin-echo to detect the occurrence of proton resonances by affecting the zero-field echo signal from the quadrupole system. The double resonance imaging method offers the advantages of higher spatial resolution and straightforward image reconstruction for powder samples compared with rotating-frame and Zeeman-perturbated nuclear quadrupole resonance encoding techniques.

Journal Article↗

Improving resolution in fast rotating-frame experiments.

The rapid rotating-frame technique allows significant reduction in data-acquisition time compared with the two-dimensional method by stroboscopic observation of the nuclear magnetization during its evolution in the rotating frame. A onefold reduction in the dimensionality of the original rotating-frame experiment is achieved by using a train of strong radiofrequency pulses separated by short acquisition windows. The penalty for shortening experimental time is a reduction in spectral resolution compared with the two-dimensional method due to relaxation of transverse magnetization components during the observation windows. A variant of the rapid-rotating frame technique for improving spectral resolution based on undersampling and self-phase encoding is presented. An M-fold resolution improvement requires M experiments, thus, making possible a tradeoff between spectral resolution and experimental time. The technique was applied for spatial localization of quadrupole nuclei in powder solids, and resolution improvement is demonstrated on one- and two-dimensional NQR images.

Journal Article↗

Oral vaccination with autologous platelets in chronic autoimmune thrombocytopenic purpura.

Idiopathic thrombocytopenic purpura (ITP) is a common disease of autoimmune mechanism in which nearly 40% of patients need a third-line treatment after steroids and splenectomy failure. Due to the variable results of the multiple therapeutic modalities in refractory patients it is necessary to develop a more effective treatment. Following previous assays of immunotolerance with the administration of "oral vaccines", we propose a therapeutic protocol in chronic ITP patients with autologous cryopreserved or liophilized platelets administered in enteric capsules. The procedure is theoretically feasible and technically easy and does not need the isolation of the specific antigen target of the autoantibodies in each particular case.

Administration, Oral↗