PubMed Health⌕ Search

Biomedical subjects

F Causa

Publications and source records attributed to F Causa.

7 recordsLinked to original sources

The effective dispersion of nanovectors within the tumor microvasculature.

The effective longitudinal diffusion of nanovectors along non-permeable and permeable capillaries has been studied considering the contribution of molecular and convective diffusion based on the Taylor's theory of shear dispersion. The problem is of importance in the transport of nanovectors used for the intravascular delivery of drugs and contrast agents. It has been shown that for a given capillary size and hemodynamic conditions a critical radius acr exists for which the effective longitudinal diffusion along the capillary has a minimum: Nanovectors with a < acr diffuse mainly by Brownian diffusion whereas nanovectors with a < acr diffuse mainly by convection and the effective diffusion coefficient grows with a. In permeable conduits, the effective diffusion reduces significantly compared to normal non-leaky vessels and it has been derived that acr grows almost linearly with the hydraulic permeability Lp of blood vessels. It has been shown that the blood conduits with the largest effective longitudinal diffusivity could be preferentially targeted by the circulating vectors. Based on these findings, the following strategies are proposed to increase the number of nanovectors targeting the tumor vessels: (i) The use of nanovectors with a critical radius for normal vessels, (ii) the injecting of bolus of nanovectors with different radii, and (iii) the normalization of the tumor vasculature. Finally, it has been emphasized that the size of the vector should be selected depending on the body district where the tumoral mass is developing and on the type, malignancy, and state of the tumor.

Animals↗

Poly-epsilon-caprolactone/hydroxyapatite composites for bone regeneration: in vitro characterization and human osteoblast response.

Polycaprolactone (PCL), a semicrystalline linear resorbable aliphatic polyester, is a good candidate as a scaffold for bone tissue engineering, due to its biocompatibility and biodegradability. However, the poor mechanical properties of PCL impair its use as scaffold for hard tissue regeneration, unless mechanical reinforcement is provided. To enhance mechanical properties and promote osteoconductivity, hydroxyapatite (HA) particles were added to the PCL matrix: three PCL-based composites with different volume ratio of HA (13%, 20%, and 32%) were studied. Mechanical properties and structure were analysed, along with biocompatibility and osteoconductivity. The addition of HA particles (in particular in the range of 20% and 32%) led to a significant improvement in mechanical performance (e.g., elastic modulus) of scaffold. Saos-2 cells and osteoblasts from human trabecular bone (hOB) retrieved during total hip replacement surgery were seeded onto 3D PCL samples for 1-4 weeks. Following the assessment of cell viability, proliferation, morphology, and ALP release, HA-loaded PCL was found to improve osteoconduction compared to the PCL alone. The results indicated that PCL represents a potential candidate as an efficient substrate for bone substitution through an accurate balance between structural/ mechanical properties of polymer and biological activities.

Alkaline Phosphatase↗

In vitro bioactivity of poly(epsilon-caprolactone)-apatite (PCL-AP) scaffolds for bone tissue engineering: the influence of the PCL/AP ratio.

Porous poly(epsilon-caprolactone) (PCL) is used as long-term bioresorbable scaffold for bone tissue engineering. The bone regeneration process can be enhanced by addition of carbonated apatites (AP). This study was aimed at evaluating the influence of the PCL/AP ratio on the in vitro degradation and bioactivity of PCL-AP composites. To this purpose, PCL-AP samples were synthesised with the following PCL/AP weight/weight ratios: 50/50, 60/40 and 75/25. Vibrational IR and Raman spectroscopies coupled to thermogravimetry (TG) and differential scanning calorimetry (DSC) were used to investigate the in vitro degradation mechanism in different media: 0.01 M NaOH solution (pH=12), saline phosphate buffer at pH 7.5 (SPB), esterase in SPB and simulated body fluid (SBF) at pH 7.5. The latter medium was used to evaluate the bioactivity of the composites. A control PCL sample was analysed before the addition of the AP component. As regards the untreated samples, the method of synthesis utilised for preparing the composite was found to enhance the crystallinity degree. The AP component revealed to be constituted of a B-type carbonated hydroxyapatite with a 3% carbonate content. After 28 days of treatment, the samples showed different degradation patterns and extents depending on the degradation medium, the starting PCL crystallinity and composite composition. Weight measurements, Raman and TG analyses revealed deposition of an apatitic phase on all the composites immersed in SBF. Therefore, all the samples displayed a good bioactivity; the sample which showed the most pronounced apatitic deposition was 50/50, i.e. that containing the highest amount of AP.

Apatites↗

Poly(2-hydroxyethyl methacrylate) biomimetic coating to improve osseointegration of a PMMA/HA/glass composite implant: in vivo mechanical and histomorphometric assessments.

Bone implants must simultaneously satisfy many requirements, even though the surface properties remain a crucial aspect in osseointegration success. Since a single material with a uniform structure cannot satisfy all of these requirements, composite materials specifically designed for orthopedic or dental implant application should be envisaged. Two poly(methylmethacrylate)/hydroxyapatite composites reinforced by E-glass fibres, uncoated (PMMA/HA/Glass) and poly(2-hydroxyethyl methacrylate) (PMMA/HA/Glass+pHEMA) coated by the biomimetic method, were mechanically (push-out test) and histomorphometrically (Affinity Index, AI) investigated in an in vivo rabbit model. Cylindrical implants (diameter 2 mm x 5 mm length) were inserted into rabbit femoral cortical (mid-diaphysis) and cancellous (distal epiphysis) bone, under general anesthesia. The highest values of push-out force and ultimate shear strength were observed for the PMMA/HA/Glass at 12 weeks, which significantly (p < 0.001) differed from those of PMMA/HA/Glass+pHEMA at the same experimental time and from those of PMMA/HA/Glass at 4 weeks. At both experimental times, significantly (p < 0.0005) lower values of AI were observed in the PMMA/HA/Glass+pHEMA versus PMMA/HA/Glass (distal femoral epiphysis: 4 weeks = 33%; 12 weeks = 19%; femoral diaphysis: 4 weeks = 15%; 12 weeks = 11%). The good mechanical and histomorphometric results obtained with PMMA/HA/Glass should be followed by further evaluation of bone remodeling processes and mechanical strength around loaded PMMA/HA/Glass implants at longer experimental times. Finally, the biomimetic method applied to pHEMA needs to be further investigated in order to improve the positive effect of SBF on pHEMA and to enhance the coating adhesion.

Animals↗

Osteoblast growth and function in porous poly epsilon -caprolactone matrices for bone repair: a preliminary study.

Current methods for the replacement of skeletal tissue involve the use of autografts, allografts and, recently, synthetic substitutes, which provide a proper amount of material to repair large bone defects. Engineered bone seems a promising approach, but a number of variables have to be set prior to any clinical application. In this study, four different poly caprolactone-based polymers (PCL) were prepared and tested in vitro using osteoblast-like Saos-2 cells. Differences among three-dimensional polymers include porosity, addition of hydroxyapatite (HA) particles, and treatment with simulated body fluid. Biochemical parameters to assess cell/material interactions include viability, growth, alkaline phosphatase release, and mineralization of osteoblastic cells seeded onto three-dimensional samples, while their morphology was observed using light microscopy and SEM. Preliminary results show that the polymers, though degrading in the medium, have a positive interaction with cells, as they support cell growth and functions. In the short-term culture (3-7 days) of Saos-2 on polymers, little differences were found among PCL samples, with the presence of HA moderately improving the number of cells onto the surfaces. In the long term (3-4 weeks), it was found that the HA-added polymers obtained the best colonization by cells, and more mineral formation was observed after coating with SBF. It can be concluded that PCL is a promising material for three-dimensional scaffold for bone formation, and the presence of bone-like components improves osteoblast activity.

Biocompatible Materials↗

Spatial and structural dependence of mechanical properties of porcine intervertebral disc.

Structure-function relationship of natural tissues is crucial to design a device mimicking the structures present in human body. For this purpose, to provide guidelines to design an intervertebral disc (IVD) substitute, in this study the influence of the spatial location and structural components on the mechanical properties of porcine IVD was investigated. Local compressive stiffness (LCS) was measured on the overall disc, also constrained between the two adjacent vertebrae: the dependence on the lumbar position was evaluated. The compliance values in the anterior position (A) were higher than both in the central posterior (CP) and in the lateral-posterior (RP, LP) locations. The values of Young's Modulus (74.67+/-6.03 MPa) and compression break load (1.36x10(4)+/-0.09x10(4)N) of the disc were also evaluated by distributed compression test. The NP rheological behavior was typical of weak-gels, with elastic modulus G' always higher than viscous modulus G" all over the frequency range investigated (G' and G" respectively equal to 320 and 85 Pa at 1 Hz) and with the moduli trends were almost parallel to each other.

Journal Article↗