PubMed Health⌕ Search

Biomedical subjects

F Collart

Publications and source records attributed to F Collart.

64 records · Page 4Linked to original sources

Haemodialysis, continuous ambulatory peritoneal dialysis and cellular immunity.

The cellular immunity of haemodialysis and continuous ambulatory peritoneal dialysis (CAPD) patients was studied with regards to T-lymphocyte subsets and to suppressor T-cell function. The two groups of patients showed similar alterations: low proportions of suppressor-cytotoxic T-cells and low suppressive activity. In both groups there is a deterioration of this suppressive activity with time on dialysis.

Aged↗

Belgian peer review experience on the Achille's Heel in haemodialysis care: vascular access.

AIMS: In order to improve the supervision and to evaluate the quality of care in dialysis units, a national project was promoted as a Peer Review. It consisted of systematic, continuous and critical evaluation of the care and the application of international guidelines and compared the reality of care with standards. METHOD: The first chart consisted of the evaluation of infectious episodes of vascular access. This point is particularly relevant since infection represents the second cause of mortality in haemodialysis. A questionnaire concerning each patient was designed. Questions concerned the description of vascular access and the related infectious events. Each questionnaire included 21 items. The project involved 29 dialysis centres, 1,644 patients and 1,775 vascular accesses. The database included 90,525 data. RESULTS: Among the 29 centres, the native arteriovenous fistula (AVF) is the first choice (67.5%) in vascular access, but the proportion of AVF decreases with age contrary to the catheter, which is more frequently chosen, in older patients. Independent of age, 20% of hospitalisations are among patients with catheters and only 7% among patients with AVF. The RR (relative risk) of being hospitalised (any complication of vascular access) is 1.68 for patients with catheters compared to patients with AVF. The rate of infections does not increase with age but is higher for patients with catheters (RR = 2.26). The number of infections appears to be dependent on the staphylococcus aureus carriage in the year. CONCLUSIONS: This first step allows each centre to compare itself to others in an anonymous way. This approach should lead to specific recommendations to improve the quality of care in dialysis units.

Age Distribution↗

Extrapulmonary small cell carcinoma following augmentation enterocystoplasty.

Tumours developing after urinary tract or bladder reconstruction with intestinal tissue have well been described. Adenocarcinomas and transitional cell carcinomas are the most frequent histological features. We report here a case of small cell carcinoma developing after augmentation enterocystoplasty. This rare observation is an opportunity to review the literature about extrapulmonary small cell carcinoma and tumours developing after uro-intestinal reconstruction surgery.

Anastomosis, Surgical↗

A previously undescribed side effect of icodextrin: overestimation of glycemia by glucose analyzer.

OBJECTIVE: Serious discrepancies between glycemia measurements obtained with an Accutrend Sensor (Boehringer Mannheim GmbH, Mannheim, Germany) type analyzer (based on a glucose dehydrogenase enzymatic reaction) and measurements obtained in the laboratory by a reference method (hexokinase) have been found in an insulin-requiring, diabetic, continuous ambulatory peritoneal dialysis (CAPD) patient treated with icodextrin 7.5% (Extraneal; Baxter Healthcare SA, Castlebar, Ireland), a new osmotic agent for peritoneal dialysis. We therefore investigated the respective role of the Analyzer and of the glucose polymer in this hitherto undescribed problem. DESIGN: Glycemia was measured simultaneously on venous blood using a reference laboratory technique, and on capillary blood using the Accutrend Sensor glucose analyzer in three groups of CAPD patients: 6 patients on Extraneal for at least 1 week, 6 patients receiving their first Extraneal exchange, and 8 patients never exposed to Extraneal. In the first group of patients, glycemia was also measured with another analyzer (Glucocard; Menarini Diagnostics, Firenze, Italy) using a different enzymatic reaction (glucose oxidase). In a separate study, whole blood of a normal subject was spiked with concentrated solutions of glucose and icodextrin and some of its metabolites (maltose, maltotriose, maltopentaose). Once again, comparative measurements of glycemia were performed with the Accutrend Sensor, with two other kits using a glucose dehydrogenase enzyme reaction, and with the hexokinase reference method. RESULTS: In 6 CAPD patients treated with once-daily exchanges with Extraneal for a minimum of 7 consecutive days, we confirmed overestimation of glycemia by the Accutrend Sensor of 65 +/- 26 mg/dL compared to reference values (p < 0.01), and of 69 +/- 25 mg/dL (p < 0.001) compared to measurements obtained with the Glucocard monitor. In 6 other CAPD patients studied at the end of one single icodextrin exchange, overestimation of 61 +/- 11 mg/dL was already present (p < 0.001). On the other hand, in 8 CAPD patients never treated with icodextrin, there was no discrepancy between the Accutrend Sensor readings and reference values. The measurements in spiked blood confirmed that only the Accutrend Sensor overestimates glycemia in the presence of maltose and glucose polymers. The overestimation decreased as the molecular size of the saccharides added to blood increased. There was no overestimation when other kits using a dehydrogenase enzyme were tested. CONCLUSION: The overestimation observed is probably related to the presence of oligosaccharides (mainly maltose), derivatives of glucose polymers present in Extraneal and absorbed via the peritoneal route, in the blood of patients treated with icodextrin. The glucose dehydrogenase characterizing the Accutrend Sensor, an enzyme of the pyrroloquinolinequinone class, very likely reacts with the free reducing group of the glucose molecule located at the end of each saccharide chain. This would not be the case for the Glucocard monitor using glucose oxidase, for other kits using glucose dehydrogenase, and for the reference method based on hexokinase. The Accutrend Sensor type of analyzers are therefore not suitable for regular monitoring of glycemia in diabetic PD patients treated with icodextrin.

Aged↗