PubMed Health⌕ Search

Biomedical subjects

F Cros

Publications and source records attributed to F Cros.

7 recordsLinked to original sources

The venous return simulator: an effective tool for investigating the effects of external compression on the venous hemodynamics--first results after thigh compression.

BACKGROUND: To present a virtual model, the venous return simulator (VRS), designed to compute venous hemodynamic variations when compression is applied to the leg. METHODS: The VRS defines a numerical network of the lower extremity and computes the dynamic variables (flow rate, venous diameter and internal pressure) for a defined external pressure. The VRS was based on physiological data from the literature and clinical studies on healthy subjects. Clinical correlations were required to confirm its validity; for this purpose, we carried out experiments simulating the conditions of a clinical trial, in which the diameter of superficial and deep veins was measured while increasing pressures (20, 40 and 60 mmHg.) were applied to the thighs of patients enduring deep valvular insufficiency and venous ulcers. The diameters and flow rates calculated using our VRS model were compared with the experimental data obtained at the same thigh compression levels. RESULTS: The numerical results of VRS are in good agreement with the clinical data obtained by Duplex, (R2 = 0.96). In accordance with the in vivo measurement the computed results show that only a pressure greater than 40 mmHg is able to reduce the venous diameter at thigh-level, both in the great saphenous vein and in the femoral vein. CONCLUSION: The venous return simulator computes lower limb hemodynamic parameters under static conditions. The good correlation existing between the VRS and the data obtained in a previous clinical study shows that this numerical approach could provide a useful means of predicting the hemodynamic consequences of compression therapy.

Bandages↗

A digital model for the venous junctions.

The venous network in the lower limbs is composed of a considerable number of confluent junctions. Each of these singularities introduces some blood flow disturbances. Each physiological junction is unique, in terms of its geometry as well as the blood flow rate. In order to account for this great variability, we developed a numerical model based on the use of the N3S code (a software package for solving Navier-Stokes equations). To test the validity of the model, one of the numerical simulations is compared with the data obtained in the corresponding experimental configuration. The velocity measurements were carried out with an ultrasonic pulsed Doppler velocimeter. We also measured pressure differences using differential sensors. The numerical computations were then used to obtain the values of the flow variables at any point, with various geometrical and flow configurations. As far as the velocity field is concerned, a very marked three-dimensional pattern with swirls was observed. The pressure evolution was also strongly disturbed, with a non-linear decrease. All these data indicate that confluence effects cannot be neglected when evaluating pressure decreases. With a tool of this kind, it is possible to accurately predict the disturbances associated with any geometrical configuration or any flow rate.

Blood Flow Velocity↗

Xenon-131 surface sensitive imaging of aerogels in liquid xenon near the critical point.

In recent years, optically pumped xenon-129 has received a great deal of attention as a contrast agent in gas-phase imaging. This report is about the other NMR active xenon isotope (i.e., xenon-131, S = 32) which exhibits distinctive features for imaging applications in material sciences that are not obtainable from xenon-129 (S = (1/2)). The spin dynamics of xenon-131 in gas and liquid phases is largely determined by quadrupolar interactions which depend strongly on the surface of the surrounding materials. This leads to a surface dependent dispersion of relaxation rates, which can be substantial for this isotope. The dephasing of the coherence due to quadrupolar interactions may be used to yield surface specific contrast for imaging. Although optical pumping is not practical for this isotope because of its fast quadrupolar relaxation, a high spin density of liquid xenon close to the critical point (289 K) overcomes the sensitivity problems of xenon-131. We report the first xenon-131 magnetic resonance images and have tested this technique on various meso-porous aerogels as host structures. Aerogels of different densities and changing levels of hydration can clearly be distinguished from the images obtained.

Gels↗

Quenched molecular reorientation and angular velocity in nanopores.

A theoretical treatment shows how the orientational dependent and spin rotation relaxation rates of a confined nonpolar liquid depend on the average pore size. Experimental nuclear relaxation data on carbon disulfide and cyclohexane in a set of calibrated porous glasses support the theory.

Anisotropy↗