DNA analysis using an electrospray scanning mobility particle sizer.

A scanning mobility particle sizer (SMPS) allows size separation of gas phase particles according to their electrophoretic mobilities. The addition of an electrospray source (ES) recently allowed extension of SMPS analysis to the macromolecular range. We demonstrate here the application of ES-SMPS to nucleic acids analysis. Single- and double-stranded DNA molecules ranging from 6.1 kDa (single-stranded DNA 20 nucleotides in length) to 300 kDa (500 base-pair double-stranded DNA) were separated and detected by ES-SMPS at the picomole to femtomole levels. The measured electrophoretic mobility diameters were found to correlate with the analytes' molecular weights, while the peak areas could yield quantitative information. No fragmentation of DNA was observed under the conditions employed. Different apparent densities were observed for single-stranded and double-stranded DNAs, showing a different behavior for each type of biomolecule. The total analysis time was about 3 min/spectrum. Further optimization of ES-SMPS is expected to make it a fast and sensitive technique for biopolymer characterization.

DNA↗

Electrospray-condensation particle counter: a molecule-counting LC detector for macromolecules.

A new detector for macromolecular separations is described. The detector counts individual macromolecules (molecular weights greater than about 10,000) and reports counts per second. The chromatographic effluent is electrosprayed, neutralized, and swept to the detector by a stream of air. The detector is a condensation particle counter that detects individual particles by light scattering from droplets condensed on the particles. When used as the detector for a size exclusion separation of proteins, the detector has a linear range of 4 orders of magnitude with detection limits as low as 0.1 microgram/mL. The detector can be directly interfaced (no makeup flow) with effluent flows as low as 10 nL/min. A Monte Carlo model based on size measurements of the electrosprayed droplets correctly predicts the observed detector behavior.

Biopolymers↗

A new peritoneovenous shunt.

For today's most common peritoneovenous shunt catheters, the high incidence of complications (disseminated intravascular coagulation [DIC], pulmonary problems, clotting of the intravascular end, and shunt kinking) results in limited use. We have designed a new peritoneovenous shunt catheter in which we improved mechanical biocompatibility with respect to both the peritoneum and the vasculature. The device consists of: a multimicroorifice ascites filter in a double-chambered collecting device, a tubular compression pump with an intratubular check-valve, and a check-valve catheter at the intravascular end for positive exclusion of blood by reflux or back diffusion. This configuration filters the proteinaceous material from the ascites fluid, transports the filtrate into the blood stream, maintains patency, act to prevent DIC by inhibiting the creation and transport of microthrombi into the cardiovascular system, and eliminates clot formation at the intravascular end.

Aged↗

The use of an implantable insulin pump in the treatment of type II diabetes.

We treated five patients with Type II diabetes by means of a subcutaneously implanted intravenous insulin pump and compared their metabolic response with that observed during conventional insulin therapy. The use of the pump improved control of glycemia, as manifested by reductions in mean plasma glucose (from 188 +/- 46 to 106 +/- 12 mg per deciliter [mean +/- S.D.]), fasting glucose (from 187 +/- 42 to 80 +/- 13 mg per deciliter), and postprandial glucose (from 287 +/- 74 to 182 +/- 29 mg per deciliter), together with a diminution of glycemic excursion and normalization of glycosylated hemoglobin A1 (from 12.1 +/- 2 to 8.0 +/- 1 per cent). At the end of the study the pumps had been in place for a mean of 7.0 months (range, 5.5 to 9.7 months) without mishap and with good patient acceptance. Our data suggest that improved blood glucose control can be achieved by means of a permanently implanted continuous insulin-infusion device in ambulatory patients with Type II diabetes who require insulin, and that the need for daily insulin injections can thereby be eliminated.

Adult↗

Control of blood glucose in experimental diabetes by means of a totally implantable insulin infusion device.

Near-normal glucose tolerance tests in diabetic dogs were obtained during basal rate insulin infusions in restrained animals by use of extracorporeal infusion pumps and in conscious, unrestrained animals by means of implanted infusion pumps. Even better regulation of blood glucose in diabetic animals was obtained by the addition of predetermined pulses of insulin at higher flow rates than the basal flow rate, accomplished by use of a transcutaneously activated valve mechanism attached to the implanted infusion pump. We conclude that near-normal blood glucose concentrations can be maintained throughout the day in the dog by these means and that similar approaches, using implantable infusion pumps, in man may lead to better long-term control of diabetes than is currently available.

Animals↗

Study leave in UK.

Explore the source record for details and available documents.

Bedding and Linens↗