PubMed HealthSearch

Biomedical subjects

F D Loop

Publications and source records attributed to F D Loop.

238 records · Page 14Linked to original sources

Cardiac rhythm and conduction disturbances in patients undergoing mitral valve surgery.

The occurrence and course of supraventricular rhythm and atrioventricular conduction disturbances were retrospectively compared in 206 patients with isolated mitral valve disease undergoing either valve replacement or ring annuloplasty (mitral repair) between January 1, 1985 and December 31, 1986. The replacement and repair groups were the same size and had approximately equal numbers of patients in sinus rhythm and atrial fibrillation preoperatively. The type of mitral valve operation did not affect the short-term outcome in terms of cardiac rhythm. For both groups, the incidence of patients crossing from sinus rhythm to atrial fibrillation and vice versa on the pre-discharge electrocardiography was equal, and both groups had a low incidence of clinically significant atrioventricular block.

Adult

Mortality of patients transferred to a tertiary care hospital.

BACKGROUND: Seriously ill patients are often transferred from community hospitals to tertiary care hospitals. OBJECTIVES: To review the numbers, sources, and outcomes of patients transferred to the Cleveland Clinic Hospital from 1989 through 1992. METHODS: Retrospective analysis. RESULTS: Compared with the Cleveland Clinic's overall hospital mortality rate of 3.09% (3760 of 121,014 patients) during this period, the mortality rate among transferred patients was 8.26% (1092 of 13,226 patients). Although transferred patients accounted for only 10.9% of the total admissions, they represented 29.0% of the deaths. Transfers from other hospitals in the Cleveland Health Quality Choice (HQC) program, a community-wide quality-assessment project, increased 40.2% in 1992 (during the initial data collection period for the HQC program), while those from non-HQC hospitals increased only 0.9%. CONCLUSIONS: Patients transferred to a tertiary care hospital from other acute care hospitals have a 2.7-fold greater chance of dying in the hospital than nontransferred patients. Public scrutiny of quality may increase the likelihood of transfer of seriously ill patients to tertiary care centers.

Diagnosis-Related Groups

Technical and economic feasibility of reusing disposable perfusion cannulae.

The reuse of disposable devices is a potential source of significant cost savings to hospitals. Venous and arterial perfusion cannulae under new and reused conditions were selected to identify the clinical, safety, technical, logistic, and economic issues that must be addressed to realize these savings. Single- and dual-stage venous and arterial cannulae from two manufacturers were tested when new, after initial clinical use, and after a single clinical use plus up to nine simulated reuses. Reuse was simulated by end-to-end bending, coupling and uncoupling the connectors, and by two 1-hour soaks in plasma at 4 degrees C and 40 degrees C, respectively. Cannulae were decontaminated and then sterilized by a peracetic acid based liquid chemical sterilization system following each use/reuse. Sterilization was validated by eliminating Bacillus subtilis spores from the cannulae on each of five consecutive cycles. Cannulae were tested for physical changes, functional integrity, biocompatibility, and in vivo performance in sheep. A cost minimization analysis was also performed. No clinically important differences were found between new and reused cannulae, even after nine simulated reuses. Mechanical changes were less than 20% on all variables studied and were undetectable by experienced cardiac surgeons in selective evaluation. Sterilization was successfully achieved. Reusing cannulae for times would reduce the cost per procedure from $53 to $19 (64%). Perfusion cannulae tested can be safely and efficaciously used five times. This study suggests that reuse would result in a small incremental savings; however, with more expensive devices and higher-volume sterilization procedures, the savings could be exponentially greater. Although this study demonstrates that it may be technically feasible and cost-effective to reuse disposable cannulae, the U.S. Food and Drug Administration does not sanction the reuse of disposable cannulae.

Animals