Inverse effect of chronically elevated blood flow on atherogenesis in miniature swine.

The effect of chronically elevated blood flow on the development of atherosclerosis in miniature swine was studied. Fistulas connecting the right external iliac artery and vein were surgically created in four swine, while three were not fistulated. Pulsed Doppler velocity detection cuffs placed around the abdominal aorta and both iliac arteries of all pigs permitted chronic measurements of blood velocity, blood velocity distributions, and blood flow. All swine were fed an atherogenic diet consisting of 20% beef tallow, 3% cholesterol, and 5% cholic acid for 6 months. This diet elevated the serum cholesterol to values exceeding 500 mg/100 ml. Creation of the arteriovenous fistula (AVF) markedly elevated blood velocity and flow in the abdominal aorta and in the shunted iliac artery. In the shunted animals the aortic blood flow was 42.1 +/- 2.0 ml/sec compared with 17.3 +/- 1.4 ml/sec in the unshunted swine. The velocity distribution pattern across the vessel was also indicative of an elevated wall shear stress. After 6 months, the animals were killed and the arterial vessels examined macroscopically and microscopically for the presence of atherosclerotic lesions. In the shunted pigs, 17 +/- 15% of the lumenal surface was occupied by sudanophilic lesions, whereas 80 +/- 8% of the surface was covered by lesions in the unshunted (control) pigs. From these studies, it is apparent that mechanical factors related to blood flow rates can influence the development of atherosclerotic lesions in swine.

Animals↗

Venous ultrasound catheter-tip technique for evaluation of arterial hemodynamics.

A variety of devices has been used for measuring flow properties of deep-lying arteries, but many have limitations. This paper describes a relatively nontraumatic intravenous approach which uses a catheter in connection with a pulsed ultrasonic Doppler velocity meter (PUDVM) and an ultrasound echo track. The venous ultrasound catheter (VUC) has permitted measurements of local instantaneols blood velocity, flow, and wall motion in the abdominal aorta and iliac arteries of beagle dogs; evaluation studies have been conducted to compare the VUC recordings with an independent method for measuring blood flow and wall motion. Coupling of this catheter-tip device with the PUDVM and echo track provides chronic measurements of hemodynamic parameters in these deep vessels which were virtually impossible to obtain previously. This technique may prove useful in monitoring vessel pathology longitudinally as well as in basic experimental situations requiring flow and arterial wall mechanical properties.

Animals↗

Nontraumatic aortic blood flow sensing by use of an ultrasonic esophageal probe.

The measurement of blood velocity fields, volume flow, and arterial wall motion in the descending thoracic aorta provides essential hemodynamic information for both research and clinical diagnosis. The close proximity of the esophagus to the aorta in the dog makes it possible to obtain such data nonsurgically using an ultrasonic esophageal probe; however, the accuracy of such a probe is limited if the angle between the sound beam and the flow axis, known as the Doppler angle, is not precisely known. By use of a pulsed Doppler velocity meter (PUDVM) and a triangulation procedure, accurate empirical measurement of the Doppler angle has been obtained, allowing quantification of blood velocity scans across the aorta. Volume flow is obtained by integration of blood velocity profiles and arterial wall motion is measured with an ultrasonic echo tracking device. Accuracy of the probe was substantiated by comparison with ultrasonic and electromagnetic implanted flow cuff measurements. Use of the probe in measurement of blood velocity, volume flow and arterial wall motion at various locations along the 8- and 10-cm length of the descending thoracic aorta in adult beagle dogs is detailed. The simplicity, accuracy, and nontraumatic aspect of the technique should allow increasing use of such a probe in numerous research and clinical applications.

Animals↗

The pulsed Doppler ultrasound flowmeter: experimental evaluation of velocity accuracy and range resolution.

Accurate quantitation of blood flow patterns, particularly in the physiological state, is important to the successful study of several problems in biomedical research. The pulsed Doppler ultrasonic flowmeter offers promise of overcoming some of the difficulties present in other methods. This flowmeter can be either implantable or noninvasive. Although a number of papers describe important design criteria, the design or selection of a Doppler system for a given task remains a complex matter involving many compromises based on theoretical considerations and very limited data. Experimental data from well-defined flows are needed to help identify those areas in which ultrasonic flowmeters can be most useful. This paper defines and evaluates two important parameters for the pulsed Doppler ultrasonic flowmeter by comparing experimental results with those predicted theorectically. The first parameter is velocity accuracy; the second parameter is range resolution. Findings show that centerline flow velocities in circular tubes can be estimated to within a few percent of the correct value, and that a 1.5-mm range resolution can be realized with the system tested.

Blood Flow Velocity↗