PubMed Health⌕ Search

Biomedical subjects

F D Roemer

Publications and source records attributed to F D Roemer.

6 recordsLinked to original sources

There isn't an ideal smooth-surface material--yet: the history and future of urologic materials.

Indwelling and implantable urologic devices did not become commercially available until the late 1970s. The first such device was a ureteral stent made of silicone. Other materials-polyethylene, polyurethane, C-Flex, and Percuflex-have since been introduced. Each of these materials is rated for a particular indwell time, after which the material may begin to break down. Various methods of modifying the surface to make it more slippery or to prevent infection have been tested. Attempts have been made to create artificial organs and have not been entirely successful, and the future may lie with tissue-engineered materials such as small intestinal submucosa.

Artificial Organs↗

Laparoscopic pneumodissection: results in initial 20 patients.

BACKGROUND: The efficiency of laparoscopic procedures has been hindered by a lack of instrumentation for blunt tissue dissection. We evaluated here the efficacy of a new 5-mm laparoscopic dissecting instrument, a pneumodissector. This instrument allows the surgeon to use short bursts of high-pressure carbon dioxide to bluntly dissect fatty tissue. STUDY DESIGN: In 20 patients undergoing a variety of laparoscopic procedures, a 5-mm laparoscopic pneumodissector was used. Subjective assessment of the efficacy of the instrument was recorded. In addition, acid-base changes were measured by blood gas determination, and serum chemistries were obtained before, during, and after the procedure. RESULTS: The pneumodissector enhanced dissection of the kidney, ureter, and major blood vessels and shortened the operative time for laparoscopic nephrectomy. Although statistically significant changes in acidbase values occurred with use of the pneumodissector, these changes were not clinically significant and were no different than what is normally seen during carbon dioxide pneumoperitoneum. CONCLUSIONS: Laparoscopic pneumodissection is a safe and efficacious technique for rapid blunt tissue dissection.

Acid-Base Equilibrium↗

Laparoscopic pneumodissection: initial clinical experience.

OBJECTIVES: We evaluated the efficacy of a new laparoscopic dissecting instrument that fires intermittent bursts of high-pressure carbon dioxide to separate tissue along natural planes. METHODS: The pneumodissector (PD) was used in 2 patients undergoing laparoscopic procedures. Serum creatinine and bicarbonate were measured before and after the procedure, and arterial blood gases were measured before, during, and after use of the PD. Subjective assessment of the ease of dissection with the PD by the first assistant was recorded. RESULTS: Acidosis and hypercarbia were not observed with use of the PD. The PD facilitated dissection along the iliac vessels, around the kidney, and in the renal hilum. CONCLUSIONS: The PD is a feasible method for rapid, blunt dissection during laparoscopic procedures.

Adolescent↗

A new renal tourniquet for open and laparoscopic partial nephrectomy.

PURPOSE: We describe a novel double loop renal parenchymal tourniquet for obtaining hemostasis during open and laparoscopic partial nephrectomy. METHODS: One loop is positioned around the upper and 1 around the lower renal poles, thus securely entrapping the kidney. During partial nephrectomy the corresponding loop is double looped and cinched, thus achieving a tourniquet effect. The renal artery is not occluded. Intraoperative renal hypothermia is not required. RESULTS: The renal tourniquet was used clinically during 6 open and 1 laparoscopic partial nephrectomies. Furthermore, during laparoscopic nephrectomy (5 porcine and 1 clinical cases) the double loop apparatus allowed for improved maneuverability of the kidney. CONCLUSIONS: The novel renal tourniquet affords adequate renal parenchymal hemostasis during open and laparoscopic partial nephrectomy.

Animals↗

Laparoscopic nephrectomy: initial case report.

A tumor-bearing right kidney was completely excised from an 85-year-old woman using a laparoscopic approach. A newly devised method for intra-abdominal organ entrapment and a recently developed laparoscopic tissue morcellator made it possible to deliver the 190 gm. kidney through an 11 mm. incision.

Adenoma↗