Methods have been developed for ambulatory BP and EKG recording on the Medilog 4/24 which provide much better accuracy and signal quality than the system currently in use. The BP signal is recorded digitally, at 20 samples/sec. and can be replayed on existing equipment with the addition of a compatible decoder module. The EKG is recorded on FM carrier, and this also can be replayed with a compatible decoder module replacing the direct mode replay module normally used.
The introduction of frequency modulated recording systems for ambulatory electrocardiographic monitoring (Oxford Medilog mark 2 and Cardiodyne cassette recorders) prompted comparison with a conventional direct recording type of recorder (Oxford Medilog mark 1). The recordings obtained by the frequency modulated recorders were very much superior to those obtained by the direct recording type of recorder. The direct recording suffered from poor low frequency response, phase shift, and cable motions artefacts. Correction of these problems with careful attention to electrode application enabled stable graphs to be obtained over 24 hours. The clinical applications were explored by comparing the results of exercie tests with a computer assisted system with frequency modulated ambulatory monitoring in 30 patients. A range of ST deviations from pure ST depressions throughout 24 hours, pure ST elevation, and a combination of ST elevation and depression were seen, suggesting a spectrum of changes hitherto unsuspected in these patients. Painless ST changes were approximately twice as common as those associated with pain. These findings indicate a valuable role for ST segment monitoring in ischaemic heart disease, particularly with the availability of high fidelity modulated tracings which do not distort ST segments.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Continuous recording of intra-arterial blood pressure and electrocardiograms has been performed in 41 ambulant untreated essential hypertensive subjects for periods up to 48 hours. Statistical analysis of the results has revealed: (1) A group of patients who developed a persistent tachycardia during the day. This response was not observed in a control population free of overt cardiovascular disease. (2) Three different haemodynamic responses to day-time activities suggesting different mechanisms for the production of high blood pressures. No normal controls are available for these changes. (3) No differences in responses between patients defined as 'labile' and 'fixed' hypertensives.
A new roentgenographic method is described for the estimation of mucous velocity in airways. Radiopaque discs of teflon mixed with bismuth trioxide were deposited in the trachea, and their motion was observed by a fluoroscopic image intensifier. Simultaneous measurements of disc movement were obtained by a previously reported cinebronchofiberscopic method and by the roentgenographic method in 6 anesthetized dogs. Mean +/- SD tracheal mucous velocity was 8.5 +/- 7.3 mm per min by the roentgenographic method, and 7.6 +/- 7.1 mm per min by the cinebronchofiberscopic method. Discrepancies between the 2 methods for individual disc velocities could be accounted for by the cumulative errors of both methods. The roentgenographic method was also used in 7 normal volunteers who did not have topical anesthesia of the tracheobronchial tree. The discs were blown through the inner channel of a bronchofiberscope, the tip of which was located just above the vocal cords. Placement of the discs on the tracheal mucosa generally did not produce coughing. Tracheal mucous velocity ranged from 7.4 to 19.4 mm per min as estimated from videotape recordings of the image intensifier images. There was no consistent difference in velocity between the erect or supine position, or after topical anesthesia with lidocaine.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A system has been devised which records direct arterial pressure, electrocardiogram, and other variables in man with no restriction of activity. The advantage of this system is that the record is on magnetic tape, and it is possible to replay the records at various speeds to analyse each beat or to produce an entire 24-hour record on a few feet of paper. A marker allows the timing of relevant events. Initial experience with this procedure indicates that is is safe and reliable.