PubMed Health⌕ Search

Biomedical subjects

F D Thomas

Publications and source records attributed to F D Thomas.

At least 19 recordsLinked to original sources

Palliation of pain associated with metastatic bone cancer using samarium-153 lexidronam: a double-blind placebo-controlled clinical trial.

PURPOSE: To evaluate the effectiveness and safety of samarium-153 (153Sm) lexidronam (EDTMP) in a double-blind, placebo-controlled study. PATIENTS AND METHODS: Patients with painful bone metastases secondary to a variety of primary malignancies were randomized to receive 153Sm-EDTMP 0.5 or 1.0 mCi/kg, or placebo. Treatment was unblinded for patients who did not respond by week 4, with those who had received placebo eligible to receive 1.0 mCi/kg of active drug in an open-label manner. Patient and physician evaluations were used to assess pain relief, as was concurrent change in opioid analgesia. RESULTS: One hundred eighteen patients were enrolled onto the study. Patients who received 1.0 mCi/kg of active drug had significant reductions in pain during each of the first 4 weeks in both patient-rated and physician-rated evaluations. Pain relief was observed in 62% to 72% of those who received the 1.O-mCi/kg dose during the first 4 weeks, with marked or complete relief noted in 31% by week 4. Persistence of pain relief was seen through week 16 in 43% of patients who received 1.0 mCi/kg, of active drug. A significant correlation (P = .01) was observed between reductions in opioid analgesic use and pain scores only for those patients who received 1.0 mCi/kg 153Sm-EDTMP. Bone marrow suppression was mild, reversible, and not associated with grade 4 toxicity. CONCLUSION: A single dose of 1.0 mCi/kg of 153Sm-EDTMP provided relief from pain associated with bone metastases. Pain relief was observed within 1 week of administration and persisted until at least week 16 in the majority of patients who responded.

Adult↗

Fluoridation in Anglesey 1993: a clinical study of dental caries in 5-year-old children who had experienced sub-optimal fluoridation.

Several studies since the commencement of fluoridation in 1955 have demonstrated over 50% reduction in mean dmft for 5-year-old Anglesey children in comparison with local control groups. From 1987 fluoridation became intermittent and in 1991 it was terminated. In the present study, carried out in 1993, the total number of children examined was 725 (88.4% of the entire population of 5-year-old school children), of whom 498 had continually resided in specific water distribution zones. The mean dmft for the entire number examined was 2.01 (SD = 3.27). For those who had experienced fluoridation during approximately 35% of their lives (n = 230) it was 1.81 (SD = 2.86) and for those who had experienced fluoridation for less than 10% of their lives (n = 268) it was 2.28 (SD = 3.48). In 1987/88, the last year of optimal fluoridation, the mean dmft of Anglesey 5-year-old children was 0.80 (SD = 1.43) and for those resident on the non-fluoridated Gwynedd mainland it was 2.26 (SD = 3.17). The study demonstrates the serious consequences for dental health when fluoridation is withdrawn and how difficult it will be to reach dental health targets in North Wales without fluoridation.

Child, Preschool↗

Transmission maximum-likelihood reconstruction with ordered subsets for cone beam CT.

An iterative algorithm is presented for accelerated reconstruction of cone beam transmission CT data (CBCT). CBCT supplies an attenuation map for SPECT attenuation compensation and anatomical correlation. Iterative algorithms are necessary to reduce truncation artifacts and 3D reconstruction artifacts. An existing transmission maximum-likelihood algorithm (TRML) is accurate but the reconstruction time is too long. The new algorithm is a modified EM algorithm, based on ordered subsets (OSEM). OSEM was evaluated in comparison to TRML using a thorax phantom and a 3D Defrise phantom. A wide range of image measures were evaluated, including spatial resolution, noise, log likelihood, region quantification, truncation artifact removal, and 3D artifact removal. For appropriate subset size, OSEM produced essentially the same image as TRML, but required only one-tenth as many iterations. Thus, adequate images were available in two to four iterations (20-30 min on a SPARC 2 workstation). Further, OSEM still approximately maximizes likelihood: divergence occurs only for very high (and clinically irrelevant) iterations. Ordered subsets are likely to be useful in other geometries (fan and parallel) and for emission CT as well. Therefore, with ordered subsets, high-quality iterative reconstruction is now available in clinically practical reconstructions times.

Algorithms↗

Dissociation of bone mineral density from age-related decreases in insulin-like growth factor-I and its binding proteins in the male rat.

We evaluated the possibility that age-related decreases in circulating and/or bone-associated insulin-like growth factor-I (IGF-I) and its binding proteins (BPs) were associated with the development of osteopenia in 8-, 16-, and 24-month-old specific pathogen-free Brown Norway/Fischer 344 male rats. We measured bone mineral densities (BMD) of femurs by dual-energy x-ray absorptiometry. IGFs and IGFBPs were extracted from bone and separated by molecular exclusion HPLC before quantitation by specific radioligand assays. BMD did not change significantly between 8 and 24 months of age. IGF-I levels decreased by about 30% between 8 and 24 months in both serum and bone. Similarly, both circulating and bone-derived IGFBPs also declined (30% and 60%, respectively) with age. Thus, maintenance of femoral BMD throughout most of the adult rat life span was dissociated from the age-related decline in circulating and bone-associated IGF-I and IGFBPs.

Aging↗

Inflammatory myofibroblastic tumor in children.

The authors presented the cases of two children with inflammatory myofibroblastic (IMF) tumor and reviewed the literature to facilitate the preoperative recognition, delineate the clinical features, and describe the natural history of this entity. The first child had IMF tumor arising from the mesentery of the small intestine. He presented with an abdominal mass associated with severe inflammatory response manifested by fever, impaired growth, thrombocytosis, and microcytic, hypochromic anemia. After surgical resection, his fever resolved and his growth rate and the laboratory abnormalities normalized. Five months after initial diagnosis, the fever, anemia, and thrombocytosis recurred along with two tumors arising from the omentum and the abdominal soft tissue. After the second surgery, he remains free of recurrent disease for 30 months. The second child presented with a lung mass that was radiologically indistinguishable from pulmonary sequestration. After surgical resection, she remains free of recurrent disease for 18 months. IMF tumor should be considered in any solid tumor that occurs in association with a chronic inflammatory response. IMF tumor should also be considered in the differential diagnosis of pulmonary sequestration.

Child↗

Phantom study of breast tissue attenuation in myocardial imaging.

The attenuation of photons by the breasts and other soft tissue overlying the chest may decrease the diagnostic accuracy of SPECT myocardial imaging. In this experiment, we measured the attenuation distortion of myocardial polar maps using a thorax phantom with a cardiac insert and added breast tissue. The distortion was measured using a regional semiquantitative analysis. Attenuation compensation was performed using a conebeam radionuclide CT attenuation map. Breast tissue attenuation created apparent "defects" in the polar map, where the intensity was reduced by up to 35% relative to the most intense region. However, the size, location and severity of the reduction depended on cardiac insert orientation and breast placement. For the geometries studied, apparent "defects" were observed in the anterior wall, the apex, the inferior wall and basal regions. These results suggest that attenuation artifacts may occur in almost any location. However, the attenuation compensation nearly eliminated the apparent defects and improved polar map symmetry. After compensation, the variations between regions were generally 5% or less. Therefore, we expect that attenuation compensation will improve diagnostic accuracy in myocardial imaging in female patients and in males with excessive musculature or soft tissue. Without such compensation, diagnosis may be compromised.

Artifacts↗

Fluoridation in Anglesey: a clinical study of dental caries in mothers at term.

A study of dental caries was carried out involving 1537 mothers who attended St David's Hospital, Gwynedd, between July 1986 and July 1987 for their confinement. The study was 'blind' in respect of residence. The mean DMFT value for mothers with continuous residence in the non-fluoridated Gwynedd mainland was 13.6 and the mean DMFT value for mothers living in the Anglesey Health Unit who had consumed fluoridated mains water from birth was 30% lower at 9.5 (P less than 0.0001). The confidence interval for the difference between means was 3.4-4.9. The samples from the two areas showed no significant differences in social class and age group structures. The percentage of Anglesey mothers with DMFT exceeding 15 was less than one-sixth of that for mainland mothers and the percentage of those with DMFT less than 6 was three times greater. The mean DMFS value for occlusal sites in premolars was 3.9 for mainland Gwynedd and for Anglesey 52% less at 1.9 (P less than 0.0001) with a confidence interval of 1.6-2.4. For smooth surface sites in posterior teeth, the difference was not as pronounced, with a mean DMFS value for mainland of 20.3 and for Anglesey 42% less at 11.8 (P less than 0.0001) with a confidence interval of 7.5-9.6. The results showed that child-bearing women continued to enjoy important benefits from water fluoridation into their early thirties.

Adult↗

Persistent pain inhibits contralateral somatosensory cortical activity in humans.

To assess cortical activity during pain perception, regional cerebral blood flow (rCBF) studies were done in humans using single photon emission computed tomography (SPECT) with the radiotracer Tc99m-HMPAO and magnetic resonance imaging localization. Normalized SPECT data were analyzed by region of interest and change distribution. Contralateral somatosensory rCBF was decreased when the digits of the hand were immersed in a hot water bath for 3 min which was rated as moderately painful (persistent pain). No decrease was observed when the hand was immersed in tepid water (control). In contrast, cortical rCBF was increased during vibratory and sensorimotor tasks, in the contralateral somatosensory and sensorimotor areas, respectively. These results indicate that pain perception in man is associated with somatosensory cortical inhibition.

Adult↗

The clinical comparison of Oxoid Signal with Bactec blood culture systems for the detection of streptococcal and anaerobic bacteraemias.

Blood cultures were taken from 47 patients 1-2 min after dental extraction. These samples were tested by the radiometric Bactec 460 and Oxoid Signal systems for the detection of streptococcal and anaerobic bacteraemias. Streptococci were isolated from 19 (40%) patients and anaerobes from 15 (32%). In this study the Oxoid Signal system was significantly better for isolating oral anaerobes than the Bactec system; five isolates were obtained with the Bactec system and 14 with the Signal system. There was no significant difference in the isolation of streptococci between these two systems (Bactec 14, Oxoid Signal 10). The contamination rate was 4.1% for Bactec and 7.5% for the Oxoid Signal system.

Adult↗

Imaging of the human torso using cone-beam transmission CT implemented on a rotating gamma camera.

Radionuclide transmission CT generated on a rotating gamma camera can improve SPECT imaging by providing attenuation maps for attenuation compensation and for anatomical correlation. This paper demonstrates the feasibility and high quality of cone-beam transmission CT (CB-CT) of human subjects, in comparison to conventional parallel-ray CT, and evaluates some possible imaging protocols. Two CB-CT implementation modes, with a cone-beam collimator and without any collimator, were evaluated. Three human subjects of different dimensions were imaged. For the two smaller subjects, the CB-CT images were dramatically superior, in terms of noise and resolution, to those obtained with a parallel-ray geometry. The image noise was less by a factor of 6. CB-CT linear attenuation coefficients were found to be in close agreement with published values for various tissues. For the largest subject, image truncation produced a ring artifact at the edge, but inside the artifact, the image quality was still very good. Cone-beam images obtained without any collimator were acceptable, but photon scatter degraded the image contrast.

Body Height↗

Pilomatrixoma: a rare condition in the differential diagnosis of a parotid swelling.

Pilomatrixoma is an uncommon tumour arising from hair follicles. It is more common in the hair bearing areas of the upper region of the body, but is relatively rare. A case is presented in which clinical examination, ultrasound and computed tomography suggested the presence of a pleomorphic adenoma arising from the superficial lobe of the parotid gland, but at operation the mass was found to be separate from it and subsequent histological examination revealed a pilomatrixoma.

Adenoma, Pleomorphic↗

Cone-beam transmission computed tomography for nonuniform attenuation compensation of SPECT images.

This paper develops and tests cone-beam transmission computed tomography (CB-CT) for attenuation compensation of SPECT images. CB-CT was implemented on a rotating gamma camera with a point source (1-2 mCi) of 99mTc, and a light-weight aluminum source holder. A cone-beam collimator may be used but is not required. Since the point source is either located at the collimator focal point, or the camera is uncollimated, CB-CT has excellent sensitivity (at least 150 times that of a parallel-hole, high-resolution collimator). The predicted resolution is equal to the intrinsic gamma camera resolution (3-4 mm), which is much higher than for a high-resolution, parallel-hole collimator (10-20 mm). In the present study, CB-CT provided low noise, high-resolution attenuation maps for use in a nonuniform attenuation-weighted backprojection algorithm. The attenuation compensation accuracy was tested using basic geometries of line sources and nonuniform density models. For the appropriate scaling of the attenuation map, the attenuation compensation was accurate and removed the SPECT image distortion associated with nonuniform attenuation. Attenuation maps acquired either with cone beam collimator or without any collimator were both successful. Using CB-CT, SPECT can thus be made much more accurate without adding unduly to the imaging time, complexity, or cost.

Algorithms↗

Prospective peritoneal scintigraphy in patients beginning continuous ambulatory peritoneal dialysis.

Forty-eight adult patients without clinical evidence of inguinal or abdominal wall hernias underwent peritoneal scintigraphy shortly after beginning continuous ambulatory peritoneal dialysis (CAPD). Scintigraphically detectable subclinical structural defects involving the inguinal canal or abdominal wall were present in 14 patients. Within 5 months, four of these defects progressed to clinically significant CAPD-related structural complications. These patients could not be distinguished by clinical or scintigraphic criteria from the 10 patients with nonprogressive structural defects. No scintigraphic structural defects were detected in 34 patients, 30 of whom remained free of CAPD-related structural complications. Five patients developed symptomatic structural complications during follow-up in areas that had been scintigraphically normal at the onset of CAPD. We conclude that some CAPD-related structural complications arise de novo, while others represent progression of subclinical pre-existent structural abnormalities that can be detected by peritoneal scintigraphy. However, most asymptomatic scintigraphic defects do not progress to a symptomatic stage, limiting the usefulness of prospective peritoneal scintigraphy as a guide to recommend prophylactic repair of all asymptomatic structural defects in patients beginning CAPD.

Adult↗

Enalaprilat-enhanced renography in a rat model of renovascular hypertension.

The effect of rapid converting enzyme inhibition (CEI) with intravenous enalaprilat on technetium-99m-(99mTc) diethylenetriaminepentaacetic acid (DTPA) and 99mTc-dimercaptosuccinic acid (DMSA) renograms was evaluated in rats with two-kidney, one-clip renovascular hypertension. Rapid sequential DTPA renograms, performed immediately before and five minutes after enalaprilat injection (30 micrograms/kg), demonstrated a selective decrease in clipped kidney DTPA plasma clearance following CEI and no significant effect on unclipped kidney function. Pre- and post-CEI data were obtained with a single injection of DMSA by administering enalaprilat five minutes after the radiopharmaceutical. Enalaprilat slowed the rate of DMSA accumulation in clipped relative to unclipped kidneys, and reduced the clipped/unclipped kidney ratio of absolute DMSA uptake at 10 and 30 min. DTPA and DMSA were equally effective in demonstrating the CEI effect. Enalaprilat was also compared with captopril (3 mg/kg, intraperitoneally), using sequential DTPA renograms. Clipped kidney DTPA plasma clearance was reduced to an identical degree (40%) by both converting enzyme inhibitors. Clinical renographic protocols can probably be devised to take advantage of the rapid, reliable CEI of enalaprilat, thereby shortening total procedure time.

Animals↗

Comparison of different radioactive renal agents in cisplatin-induced tubular toxicity in rats.

The efficacy of five different radiodiagnostic agents for detecting renal tubular dysfunction induced with cisplatin in rats was compared to controls. Diethylenetriaminepentaacetic acid (DTPA) labeled with 99mTc or 111In was administered simultaneously with each of the other four agents [99mTc]glucoheptonate, [99mTc]dimercaptosuccinic acid, [131I]hippuran and [111In]lysozyme) as a standard to normalize for differences in functional impairment from animal to animal from the same dose of cisplatin. The 2-hr plasma clearance and computer-generated 2- to 3-min uptake in the two kidneys with [99mTc]dimercaptosuccinic acid were significantly inferior to similar measurements with the other agents in differentiating abnormal from normal function. The 2-hr uptake of [99mTc]glucoheptonate and [111In]lysozyme proved of no value in this differentiation. The late renal retention of [99mTc]dimercaptosuccinic acid well separated the cisplatin from control rats, but the greatest difference was observed by the 2-hr uptakes of [131I]hippuran and DTPA.

Animals↗

Differences between caries levels in 5-year-old children from fluoridated Anglesey and non-fluoridated mainland Gwynedd in 1987.

Using standard epidemiological techniques, several indicators of dental health showed significantly lower levels of caries experience in 5-year-old children from fluoridated Anglesey compared with a similar group from non-fluoridated mainland Gwynedd. The mean dmft was 0.80 in Anglesey and 2.26 in mainland Gwynedd. The mainland Gwynedd children had suffered more toothache and experienced more dental extractions. This study showed that fluoridation of water supplies remains an effective and relevant public health measure, and illustrates the value of a parental questionnaire in epidemiological surveys of younger children.

Child, Preschool↗