PubMed Health⌕ Search

Biomedical subjects

F De Man

Publications and source records attributed to F De Man.

10 recordsLinked to original sources

Fatal prosthetic valve endocarditis due to Campylobacter fetus.

Campylobacter fetus subspecies fetus has a predilection for vascular endothelium. This report describes a case of a prosthetic valve infective endocarditis due to this microorganism. Despite adequate antibiotic combination treatment, valvular vegetations and perivalvular suppurative complications evolved, leading to valvular dysfunction, heart failure and death. Only three other cases of C. fetus prosthetic valve endocarditis have been described previously. Campylobacter fetus bacteraemia must be considered cautiously, because of the risk of late cardiac or vascular complications.

Anti-Bacterial Agents↗

Randomized coronary patency trial of double-bolus recombinant staphylokinase versus front-loaded alteplase in acute myocardial infarction.

One hundred two patients with evolving myocardial infarction of 6 hours' duration were given aspirin and intravenous heparin and randomly allocated to intravenous front-loaded, weight-adjusted rTPA administration over a 90-minute period (52 patients) or to two 15 mg doses of recombinant staphylokinase, 30 minutes apart (50 patients). Thrombolysis in Myocardial infarction (TIMI) perfusion grade 3 at 90 minutes was achieved in 68% (95% confidence interval, 55% to 81%) of patients treated with staphylokinase versus 57% (95% confidence interval, 43% to 72%) of patients treated with rTPA (p = not significant). Double-bolus staphylokinase was significantly more fibrin-specific than accelerated rTPA with residual fibrinogen at 90 minutes of 105% +/- 4.1% and 68% +/- 7.5%, respectively (p < 0.0001). Thirteen patients in each study group underwent angioplasty of the culprit coronary artery within the first 24 hours because of suboptimal recanalization (TIMI < 3). In the patients without prior coronary intervention, TIMI 3 at 24 hours was 100% after staphylokinase administration (n = 35) versus 79% after rTPA (n = 34) (p = 0.005). The distribution of inhospital events did not significantly differ between both groups. One patient receiving rTPA died in the hospital from ischemic stroke. Staphylokinase administration did not induce allergic reactions, but significant staphylokinase-neutralizing activity (> 5 micrograms/ml) and specific anti-staphylokinase IgG developed in 73% of patients after 2 weeks. Thus two 15 mg doses of staphylokinase induce early, complete, and sustained coronary artery patency at least as frequently as accelerated rTPA without associated fibrinogen degradation but with subsequent induction of circulating neutralizing antibodies.

Female↗

A randomized trial of recombinant staphylokinase versus alteplase for coronary artery patency in acute myocardial infarction. The STAR Trial Group.

BACKGROUND: Recombinant staphylokinase (STAR) was shown recently to offer promise for coronary arterial thrombolysis in patients with evolving myocardial infarction. The present multicenter randomized open trial was designed to assess the thrombolytic efficacy, safety, and fibrin specificity of STAR relative to accelerated alteplase (recombinant tissue-type plasminogen activator [RTPA]). METHODS AND RESULTS: One hundred patients with evolving myocardial infarction of < 6 hours' duration and with ST-segment elevation were allocated to accelerated and weight-adjusted RTPA over 90 minutes (52 patients) or to STAR (the first 25 patients to 10 mg and the next 23 patients to 20 mg given intravenously over 30 minutes). All patients received aspirin and intravenous heparin. The main end points were coronary artery patency and plasma fibrinogen levels at 90 minutes. Thrombolysis in Myocardial Infarction (TIMI) perfusion grade 3 at 90 minutes was achieved in 62% of STAR patients versus 58% of RTPA patients (risk ratio, 1.1; 95% CI, 0.76 to 1.5). With 10 mg STAR, TIMI grade 3 patency was 50% (risk ratio, 0.86; 95% CI, 0.54 to 1.4 versus RTPA); with 20 mg STAR, it was 74% (risk ratio, 1.3; 95% CI, 0.90 to 1.8 versus RTPA). Residual fibrinogen levels at 90 minutes were 118 +/- 47% (mean +/- SD) of baseline with STAR and 68 +/- 42% with RTPA (P < .0005). STAR therapy was not associated with an excess mortality or electric, hemorrhagic, mechanical, or allergic complications. However, patients developed antibody-mediated STAR-neutralizing activity from the second week after STAR treatment. As an addendum to the randomized study, 5 patients were given 40 mg STAR over 30 minutes, resulting in TIMI perfusion grade 3 at 90 minutes in 4 patients without fibrinogen breakdown (residual levels at 90 minutes of 105 +/- 8% of baseline). CONCLUSIONS: STAR appears to be at least as effective for early coronary recanalization as and significantly more fibrin-specific than accelerated RTPA in patients with evolving myocardial infarction.

Angioplasty, Balloon, Coronary↗

[Dental care and prevention of infectious endocarditis].

Infective endocarditis causes substantial morbidity and mortality despite adequate antimicrobial, medical and surgical treatment. The rationale for antibiotic prophylaxis against endocarditis is derived from the etiology and pathogenesis of the disease. Endocarditis usually follows bacteremia with certain endocarditis-prone bacteria in a patient with a predisposing heart condition. Protection by antibiotic prophylaxis is estimated to reach only 50% for a lot of reasons (transient bacteremia without dental or surgical intervention, predisposing heart disease not diagnosed previously, etc). Most authorities in the field of infective endocarditis strongly advocate the use of antibiotic prophylaxis for patients at risk. Clear guidelines are published by various highly qualified scientific committees. Recent schemes allow orally administered antibiotic prophylaxis because of a better doctor and patient compliance.

Administration, Oral↗

Intravascular ultrasound versus angiography for measurement of luminal diameters in normal and diseased coronary arteries.

Quantitation of coronary luminal diameter with a 20 MHz mechanically rotating intravascular ultrasound (IVUS) catheter was compared with orthogonal-view cineangiography by use of a semiautomated edge-detection algorithm in 48 patients undergoing coronary angioplasty. Quantitative comparison of 196 matched segments was attempted, but in only 174 (88.8%) was a direct comparison of the two techniques possible. In angiographically normal coronary arteries (46 segments) the correlation between the values obtained by quantitative coronary angiography (QCA) and those achieved by IVUS was excellent (r = 0.92, p < 0.0001). For mild stenoses (80 segments) the correlation coefficient was only fair (r = 0.467, p < 0.001). After percutaneous transluminal coronary angioplasty the correlation coefficient between IVUS and QCA data (48 segments) was very weak (r = 0.282, p < 0.05). In conclusion, coronary IVUS is feasible and safe and even for a limited range of coronary arterial narrowing, significant correlations between IVUS and QCA measurements of minimal lumen diameter were found. They were excellent in normal coronary arteries, moderate in mildly diseased arteries, and weak after balloon angioplasty.

Angioplasty, Balloon, Coronary↗

Role of intravascular ultrasound in coronary artery disease: a new gold standard? An overview.

Although selective contrast coronary arteriography has been the gold standard approach for coronary imaging since more than 30 years, new coronary imaging techniques are currently under development. Intravascular ultrasound (IVUS) is perhaps the most promising of these additional techniques. IVUS makes use of miniaturised crystals incorporated at catheter tips and provides real time, cross-sectional and longitudinal, high resolution images of the arterial wall with three-dimensional reconstruction capabilities (Pandian, 1989; Coy et al., 1991; Liebsen & Klein, 1992). Different devices have been constructed. Actually two types are being used: mechanical (hand-rotated or motor-driven) systems and phased array systems using high-frequency (20-30 MHz) transducers (Bom et al., 1989). Coronary ultrasound imaging performed during catheterization is feasible and safe as demonstrated in several studies examining normal and pathologic coronary arteries (De Scheerder et al., in press).

Coronary Disease↗

The use of intracoronary ultrasound for quantitative assessment of coronary artery lumen diameter and for on-line evaluation of angioplasty results.

UNLABELLED: The value of intracoronary ultrasound for quantitative assessment of minimal coronary arterial diameter and for on-line evaluation of balloon angioplasty result was studied in 42 patients undergoing single vessel coronary angioplasty. Measurement of minimal luminal diameter of 75 matched coronary arterial segments showed a significant correlation between both the ultrasound and angiographic method (r: 0.759; p < 0.001). Furthermore using intravascular ultrasound it was possible to classify the obtained coronary balloon angioplasty results. A preliminary correlation between ultrasound classification and the in-hospital acute rethrombosis as well as late restenosis was attempted in individual patients. CONCLUSIONS: 1) Clinical use of coronary ultrasound is feasible and safe in selected cases. 2) A significant correlation between intracoronary ultrasound and quantitative coronary angiography is demonstrated. 3) Using intracoronary ultrasound seems promising for evaluation of the postangioplasty result, and may finally lead to improved selection of the interventional strategy.

Angioplasty, Balloon, Coronary↗

Circulating immune complexes in chronic eosinophilic pneumonia.

In 9 out of 14 patients with chronic eosinophilic pneumonia (CEP), followed-up in our department, circulating immune complexes (CIC) and other immunologic indices were investigated. The diagnosis of CEP was based on the typical clinical and radiographic findings and on the demonstration of eosinophilia in serum, bronchoalveolar lavage (BAL), fiberoptic transbronchial biopsies and surgical lung biopsies. CIC measured by solid-phase monoclonal RF binding were always strongly positive during a flare-up of CEP, and CIC measured by solid-phase C1q binding were also positive in most cases. Remissions of CEP were accompanied by lowering or disappearance of CIC. CIC were significantly correlated with eosinophilia (p less than 0.001 for RF and p less than 0.02 for C1q). Other immunologic indices were normal except for increased IgE in two thirds of the patients, and a slightly positive rheumafactor without rheumatic disease in half of the patients. The CIC are thus related to disease activity, and can be used as one of the markers of it, in addition to the classical markers such as eosinophilia and chest X-ray. However, this does not imply that the CIC have a pathogenetic role in CEP; these CIC can, indeed, be an epiphenomenon only.

Adult↗

Double prosthetic valve endocarditis caused by Streptococcus pneumoniae.

Infective endocarditis (IE) caused by Streptococcus pneumoniae is a rare disease. Only eight cases of pneumococcal prosthetic valve endocarditis have been described in the literature. In this report we describe the first case of pneumococcal endocarditis involving two prosthetic heart valves. The patient had pneumonia as the probable portal of entry but no predisposing conditions for invasive pneumococcal disease. Our case also illustrates the importance of transesophageal echocardiography (TEE) for the early diagnosis of IE and a timely decision for cardiac surgery.

Echocardiography, Transesophageal↗

Right atrial tumor arising on an atrial septal aneurysm. Assessment by MR imaging.

An elderly women presenting with transient ischemic events underwent transesophageal echocardiography, which detected an aneurysm of the interatrial septum. A tumor protruding from the right atrial aspect of the aneurysm also was found incidentally. Not only was magnetic resonance (MRI) imaging helpful in better characterizing the aneurysm, but also the use of gadolinium diethylaminetriamine pentaacetic acid permitted differentiation between the tumor and adherent thrombus. To the best of our knowledge, this represents the first report of a tumor arising from an atrial septal aneurysm.

Aged↗