Process monitoring by parallel column gradient elution chromatography.

A system was developed that generates two gradients simultaneously, 180 degrees out of phase. Essential elements of the system were a pump delivering solvent A at a constant velocity, a pump delivering solvent B at a constant velocity, two mixing chambers, and a ten-port valve. By use of this gradient device and two reversed-phase columns packed with 1000-A pore diameter, 8-microns particle size macroporous poly-(styrene-divinylbenzene) resin, six proteins were separated in 40 s in a single gradient cycle.

Chromatography↗

Capillary electrophoretic separations of proteins using nonionic surfactant coatings.

Capillary zone electrophoretic separations of proteins have been achieved by using nonionic surfactant coated capillaries. Capillaries were prepared by derivatization of the silica surface with octadecylsilane followed by the deposition of a layer of nonionic surfactant from an aqueous solution above the critical micelle concentration. This coating is of sufficient thickness and hydrophilicity to reduce both protein adsorption and electroosmotic pumping. This hydrophilic coating reduces electroosmotic pumping 5-8-fold while resolving proteins quickly and efficiently with good recovery. The coating provides a stable and reproducible means of deactivation, while the rate of electroosmotic pumping stays relatively constant throughout the pH range 4-11. This allows the pH to be varied to enhance selectivity without adversely affecting the flow rate.

Electrophoresis↗

Semipermeable-surface reversed-phase media for high-performance liquid chromatography.

Polyoxyethylene was both adsorbed hydrophobically (through the use of non-ionic surfactants) and covalently bonded to reversed-phase high-performance liquid chromatographic packings, thereby establishing a semipermeable hydrophilic layer over the alkylsilane surface. This layer restricts proteins from adsorbing to the alkylsilane phase while permitting penetration and chromatographic separation of small molecules. Biological fluids containing low-molecular-weight analytes may be injected directly, without sample pretreatment or the use of micellar eluents. In the case of adsorbed coatings, surfactant loading was determined primarily by the surface area (over the reversed phase) occupied by the polyoxyethylene head group. Semipermeability of the hydrophilic layer was demonstrated by observing changes in retention of both small molecules and proteins with increasing eluent ionic strength. Coated column stability was evaluated with regard to cumulative eluent volume and repeated serum injections.

Adsorption↗

Coated hydrophilic polystyrene-based packing materials.

A very hydrophilic high-performance liquid chromatographic base support was created from microparticulate, macroporous poly(styrene-divinylbenzene) beads. An organic monomer containing cross-linking functionalities was coated on the poly(styrene-divinylbenzene), followed by a catalyzed cross-linking reaction. The coatings formed contain only stable chemical bonds (e.g., C-C, C-O-C), and easily-derivatized hydroxyl moieties. This coated base support was evaluated for hydrophilicity, chemical stability, solvent compatibility, rigidity, and irreversible adsorption. Derivatives of the coated base support were made and applied in various modes of chromatography.

Cations↗

Perfusion chromatography.

Perfusion chromatography is a technique based on fluid dynamics for reducing stagnant mobile phase mass transfer in liquid chromatography. This is achieved by using supports with large pores that allow mobile phase to flow through particles.

Chromatography↗

Quantification of antibodies to human growth hormone by high-performance protein G affinity chromatography with fluorescence detection.

The technique of high-performance affinity chromatography (HPAC) is applied to the quantitative determination of antibodies to human growth hormone (hGH) in serum from patients. An affinity column consisting of covalently immobilized protein G on a rigid support is used to capture the antibodies. Texas Red labeled hGH (hGH-TR) is used as a fluorescence probe for detecting the anti-hGH antibodies. Calibration curves are established by using a well-characterized monoclonal antibody to hGH (GHC101). The minimum detectable concentration (MDC) of anti-hGH antibody in serum is 250 ng/mL (this represents 10 ng of anti-hGH injected onto the protein G column). Analytical recoveries are 92-110% for seven replicates with 250-4000 ng/mL of GHC101. A precision of 15% relative standard deviation (RSD) can be achieved at the MDC. The precision is better above the detection limit. The linear dynamic range of the method is approximately 2 orders of magnitude. The total fluorescence recovery from the affinity column is greater than or equal to 96%. Sample analysis times are on the order of 20 min. The HPAC technique gives results in absolute units of concentration that correlate well with binding capacity values determined by radioimmunoassay.

Antibodies↗

Flow-through particles for the high-performance liquid chromatographic separation of biomolecules: perfusion chromatography.

This paper reports a new technique for reducing resistance to stagnant mobile phase mass transfer without sacrificing high adsorbent capacity or necessitating extremely high pressure operation. The technique involves the flow of liquid through a porous chromatographic particle, and has thus been termed "perfusion chromatography". This is accomplished with 6000-8000 A pores which transect the particle. Data from electron microscopy, column efficiency, frontal analysis and theoretical modelling all suggest that mobile phase will flow through these large pores. In this manner, solutes enter the interior of the particles through a combination of convective and diffusional transport, with convection dominating for Peclet numbers greater than one. The implications of flow through particles on bandspreading, resolution and dynamic loading capacity are examined. It is shown that the rate of solute transport is strongly coupled to mobile phase velocity such that bandspreading, resolution of proteins and dynamic loading capacity are unaffected by increases in mobile phase velocity up to several thousand centimeters per hour. The surface area of this very large-pore diameter material is enhanced by using a network of smaller, 500-1500 A interconnecting pores between the throughpores. Scanning electron micrographs show that the pore network is continuous and that no point in the matrix is more than 5000-10,000 A from a through-pore. As a consequence, diffusional path lengths are minimized and the large porous particles take on the transport characteristics of much smaller particles but with a fraction of the pressure drop. Capacity and resolution studies show that these materials bind and separate an amount of protein equivalent to that of conventional high-performance liquid chromatography as well as low performance agarose-based media at greater than 10-100 times higher mobile phase velocity with no loss in resolution.

Chromatography, High Pressure Liquid↗

Polyethyleneimine-bonded phases in the separation of proteins by capillary electrophoresis.

A hydrophilic, positively charged, durable coating has been developed for capillary electrophoresis of macromolecules. Polyethyleneimine is adsorbed to the inner wall of fused silica capillaries and the adsorbed coating cross-linked into a stable layer. Capillaries of polyethyleneimine-coated silica gave unique separations owing to the reversal of electro-osmotic flow caused by the positively charged coating. The resulting coating was stable from pH 2-12 and could be used over a wide pH range without substantial change in electro-osmotic flow. High-molecular-weight polymers were needed to give thick coatings which mask silanol groups on the wall. Proteins were resolved quickly and efficiently with good recovery using capillaries of 50 cm in length.

Animals↗

Microenvironmental contributions to the chromatographic behavior of subtilisin in hydrophobic-interaction and reversed-phase chromatography.

Genetically engineered variants were used to examine how microenvironmental changes in the S1 substrate binding subsite of subtilisin contribute to chromatographic behavior of proteins on hydrophobic-interaction chromatography (HIC) and reversed-phase chromatography (RPC) columns. Gradient elution studies over a wide pH range showed that conditions could be found where a HIC support could separate proteins varying by one amino acid. Although all single-site variants could not be separated by HIC, this chromatographic mode was found to be complementary to cation-exchange chromatography for the separation of such variants. RPC was found to be of much less utility in the resolution of variant proteins. Retention and resolution of subtilisin variants was found to vary on RPC with the concentration and type of mobile phase pairing agent.

Amino Acids↗

Thermodynamic model for electrostatic-interaction chromatography of proteins.

A thermodynamic model derived by Record et al. [M. T. Record, Jr., Biopolymers, 14 (1975) 2137 and M. T. Record, Jr., C. F. Anderson and T. M. Lohman, Q. Rev. Biophys., 11 (1978) 103] from Wyman's linkage theory [J. Wyman, Adv. Protein Chem., 19 (1964) 223] using Manning's condensation model [J. Manning, J. Chem. Phys., 51 (1969) 924] was extended to electrostatic interaction chromatography. Mixed, electrostatic and hydrophobic interactions of a model protein, ovalbumin were characterized by ion and water release.

Chromatography↗

Single amino acid contributions to protein retention in cation-exchange chromatography: resolution of genetically engineered subtilisin variants.

Genetically engineered proteins were used to determine the amino acid contributions of surface residues to subtilisin retention in cation-exchange chromatography. Crystallographic data were used to correlate the observed chromatographic behavior with enzymatic structure. Retention times of variants in gradient elution varied by as much as 33% compared to the wild type. The role of both charged and uncharged residues was investigated in isocratic separations and found to significantly influence protein retention in this electrostatically dominant separation method. This study demonstrates the ability of ion-exchange chromatography to discriminate between protein variants differing by a single residue in 275 amino acids.

Amino Acid Sequence↗

Dual-column immunoassays using protein G affinity chromatography.

Tandem protein G affinity and reversed-phase chromatography (RPC) columns, coupled with a switching valve, were used for on-line immunoassays of antibodies and antigens. Columns with reversibly immobilized antibodies were prepared by adsorbing antibodies on the protein G column. Following antigen capture in the immunoaffinity column, antigen-antibody complexes were desorbed, dissociated, and transferred to the RPC column where they were separated and quantified. This system was used to determine the titer of a rabbit anti-human transferrin antibody sample with a precision of +/- 2%. Quantitation of human transferrin in human serum had a precision of +/- 6% and showed good agreement with rate nephelometry. The linear dynamic range for the transferrin, antigen immunoassay was 5 x 10(1) to 1 x 10(5) ng with a precision of +/- 3.5%.

Chromatography, Affinity↗

Immunological-chromatographic analysis of lysozyme variants.

Immunological-chromatographic analysis (ICA) was used to evaluate the cross-reactivities of eight lysozyme variants with five different immobilized monoclonal anti-hen-egg-white lysozyme antibodies. ICA is a dual-column high-performance liquid chromatography-based method in which an immunoaffinity and a conventional analytical column are coupled with a switching valve. Antigens are first captured on the affinity column and then desorbed and concentrated on the second column, where they are separated further. This arrangement permits antigen-antibody interactions occurring on the affinity column to be monitored on-line with the second column. The ICA system was used to perform direct and competitive inhibition binding immunoassays with unlabeled antigens. Seven of the eight lysozymes tested bound to all five immobilized monoclonal antibodies. Competitive inhibition of binding of hen egg white lysozyme to the monoclonal antibody, HyHel-5, was measured by using the variants Japanese quail and bobwhite quail lysozymes as inhibitors. The ratio of the amount of bobwhite quail to Japanese quail lysozyme required to give 50% inhibition of binding of hen egg white determined by ICA compares well with the results obtained by other investigators who used an enzyme-linked immunosorbent assay plate binding assay.

Amino Acid Sequence↗

Reversed-phase liquid chromatography of proteins with strong acids.

Small organic acids are generally used as pairing agents at less than 1% concentration in reversed-phase chromatography (RPC) of proteins. When the protein is very hydrophobic and insoluble, as in the case of membrane proteins, up to 60% aq. formic acid has been used. This paper reports a study of the influence of acid concentration on both chromatographic retention and protein structure in RPC. Chromatographic retention increases in proportion to the concentration of organic acid in the mobile phase up to some intermediate concentration. Use of still higher concentrations of acid results in a sharp drop in chromatographic retention with a change in selectivity. The data indicate that the structure of proteins in strong acids are different from that in weak acids. This work examines the reason for this decrease in chromatographic retention at formic and trifluoroacetic acid concentrations above 30% (v/v). Spectroscopic studies show that protein conformation continuously changes with the addition of acid.

Acids↗

Immobilized-metal affinity and hydroxyapatite chromatography of genetically engineered subtilisin.

High-performance immobilized-metal affinity and hydroxyapatite chromatography were employed to investigate the engineered subtilisin S1 binding site microenvironment. Although these methods are classified as affinity techniques, unlike traditional affinity columns, both are capable of probing the entire surface of a molecule. The metal chelate study employed gradient elution to assemble retention maps for a wide range of mobile-phase pH. Resolution of single substitution variants was achieved at the optimum mobile-phase pH. A total of four metals were applied separately to the metal chelate column to investigate ligand specificity with respect to protein retention. Hydroxyapatite chromatography, albeit an established technique, has only recently been developed as a high-performance chromatographic method. Gradient elution separations were performed to determine selectivity. Immobilized-metal affinity chromatography was found to be the more effective method for the separation of site-specific variants.

Chromatography, Affinity↗

Immunological-chromatographic analysis.

Tandem immunoaffinity and conventional high-performance liquid chromatography columns, coupled with a switching valve, were used for the analysis of single and multicomponent antigen samples. Immunoaffinity columns were prepared by hydrophobic adsorption or covalent immobilization of poly- or monoclonal antibodies on macroporous poly(styrene-divinylbenzene) packing materials. Capacities of these columns were constant through at least 77 cycles. Macromolecular antigens were analyzed at submicrogram levels. Antigens bound to the immunoaffinity column were desorbed and concentrated on a conventional analytical column. Gradient elution on the analytical column separated the desorbed antigen(s) from interfering species and permitted the analysis of all species which bound to the immunoaffinity column. Immunological-chromatographic analysis was useful for purification and discrimination of polypeptides of similar three dimensional structures, such as several lysozyme variants.

Chromatography, Affinity↗