PubMed Health⌕ Search

Biomedical subjects

F Fack

Publications and source records attributed to F Fack.

4 recordsLinked to original sources

Heteroduplex mobility assay (HMA) pre-screening: an improved strategy for the rapid identification of inserts selected from phage-displayed peptide libraries.

Phage-displayed peptide libraries represent an efficient tool to isolate peptides that bind a given target molecule. After several selection rounds, generally a large pool of target binding phages is obtained. Conventional analysis of the selected phage population involves extensive sequencing of many clones, most of which can be identical. We have adapted the Heteroduplex Mobility Assay (HMA) for pre-screening of phage inserts that were amplified by direct colony PCR of ELISA-positive clones. This strategy allowed for the rapid and reproducible assignment of insert sequences to different 'heteroduplex migration groups'. Sequence analysis of only one representative of each HMA migration group then completes the characterisation of the binding phage population. In our model experiments, only 16% of HMA pre-screened clones required further sequence analysis.

Animals↗

Epitope mapping by phage display: random versus gene-fragment libraries.

We present a comparative study on epitope mapping of four monoclonal antibodies directed against four different antigens using alternative phage display techniques and peptide scanning: mAb215 reacts with the largest subunit of RNA polymerase II, mAbBp53-11 with the tumor suppressor protein p53, mAbGDO5 with the Hantaan virus glycoprotein G2 and mAbL13F3 with the Hantaan virus nucleocapsid protein. Epitopes were determined (i) by gene-fragment phage display libraries, constructed by DNaseI digested random gene fragments cloned into the 5' terminus of the pIII-gene of fd phage and (ii) by random peptide phage libraries displaying 6mer and 15mer peptides at the N-terminus of the pIII protein. Using the gene-fragment phage display libraries a single round of affinity selection resulted in the determination of the corresponding epitopes for all monoclonal antibodies tested. In contrast, biopanning of 6mer and 15mer random peptide libraries was only successful for two of the antibodies (mAbBp53-11 and mAbGDO5) after three or four rounds of selection. For the anti-p53 antibody we recovered the epitope from both the 6mer and 15mer library, for mAbGDO5 only the 6mer library displayed the epitope sequence. However, screening of the random peptide libraries with mAb215 and mAbL13F3 failed to yield immunopositive clones. Fine mapping of the epitopes by peptide scan revealed that the minimal epitopes recognized by mAbBp53-11 and mAbGDO5 consist of four and five amino acids, respectively, whereas mAb215 requires a minimal epitope of 11 amino acids for antigen recognition. In contrast, mAbL13F3 did not react with any of the synthesized 15mer peptides. The limits of the different methods of epitope mapping tested in this study are compared and the advantages of the gene-fragment phage display system are discussed.

Amino Acid Sequence↗

Conformational analysis of a 139 base-pair DNA fragment containing a single-stranded break and its interaction with human poly(ADP-ribose) polymerase.

The conformational changes induced by the introduction of a central and unique single-stranded break in a 139 base-pair DNA duplex have been analysed by means of polyacrylamide gel electrophoresis, HPLC and dark-field electron microscopy. Compared to the control DNA, the disruption of the covalent sugar-phosphate backbone induces a retardation detected both by gel electrophoresis and anion exchange based HPLC. Electron microscopic visualization of the DNA molecules reveals that most of them present a central fracture at the position of the nick. Measures of the angle at the apex were very well fitted by a simple model of isotropic flexible junction assuming spatial Hooke's law and simple basic Boltzmann statistics. This amounts to using a folded Gaussian distribution. The fit yields an angle equilibrium value phi 0 = 122 degrees for the nicked fragment. The angle distribution could also result from an equilibrium between two forms of the molecule with isotropic flexibility at the nicked site: a stacked and a very flexible unstacked form. The majority of bound poly(ADP-ribose) polymerase, a zinc-finger enzyme involved in DNA break detection, was localized at the apex of the V-shaped DNA duplex, with an accentuation of its general V-shaped conformation (phi 0 = 102 degrees).

Base Sequence↗

Curved DNA fragments display retarded elution upon anion exchange HPLC.

Restriction fragments containing established curved regions, such as the pBR322 tn3 region, the phage lambda attP region and the SV40 T-antigen and terminus of replication regions, exhibit systematically retarded elution upon anion exchange based HPLC. Using this method, we were able to detect readily other SV40 curved regions, exhibiting also the polyacrylamide gel electrophoresis retardation anomaly, including several RNA polymerase initiation sites. Unlike gel retardation, HPLC retardation exhibited by curved DNA persists at 55 degrees C and is observed for fragments ranging from 150 bp up to 5 kb. The observed preferential attachment of DNA fragments containing curved DNA to the ionic groups of the column suggests a common dipole character of these regions due to the local accumulation of charges resulting apparently from the compression in the minor groove of curved DNA.

Bacteriophage lambda↗