Devices for the control of laser transmission across the sclera during transscleral photocoagulation.

Improving the reproducibility of transscleral photocoagulation necessitates controlling the transmission of the laser beam through the sclera. Two factors make such control problematic: the locally increased transparency of the sclera resulting from the contact procedure and the occurrence of time-related relaxation phenomena. Two instruments have been devised to help control these factors. The first is a mechanical compensation unit comprised of magnets and a spring that allows the force exerted on the sclera to be adjusted to between 0.1 and 0.4 N, the pressure being determined by the outer diameter of the contact tip. The second instrument monitors the portion of the aiming beam reflected by the sclera as a means of determining the exact level of power actually transmitted through it. This information theoretically could be fed back to the treatment laser, allowing the level of power being delivered to be adjusted accordingly.

Ciliary Body↗

A new instrument for controlling pressure exerted on the sclera during contact Nd:YAG laser cyclodestruction.

We tested the device described by Rol et al in their article in this issue, designed to define and precisely control the pressure applied to the sclera during contact cyclodestruction with a cw-Nd:YAG laser. Since scleral transparency, and hence transmission of laser energy, depends on the pressure applied, control of this parameter represents an important advance toward the goal of standardizing the cyclodestructive procedure. In eight of nine cadaver pig eyes, pressure was exerted on the sclera using the pressure-controlling device, with a setting of 0.25 N for two of these eyes, and one of 0.4 N for the other six. In the remaining eye, pressure was controlled intuitively by an experienced surgeon. Applying forces of 0.25 or 0.4 N yielded similar success rates, although these fluctuated greatly even under constant pressure conditions (from 17% to 50% at 0.25 N; from 27% to 42% at 0.4 N). The highest success rate (55%) was achieved by the intuitively controlled pressure irradiations of the experienced surgeon. The variation in coagulation intensity that occurred despite constant pressure suggests that additional factors contribute to the results achieved. Nonetheless, this pressure-controlling probe represents an important achievement. It will permit not only the novice but even experienced operators to adhere unambiguously to a protocol of quantitative, reproducible parameters, and will also help researchers to better understand the relationship between energy delivered and intraocular pressure reduction achieved in contact cyclophotocoagulation.

Animals↗

Optical principles related to optimizing sclerostomy procedures.

A simple probe, consisting of a 200-micrometer uncladded silica optical fiber, advanced from a protecting 22-gauge hypodermic needle, was used to create sclerostomy fistulas both ab interno and ab externo by means of a combined radiation/mechanical effect. Perforation was achieved by exerting gentle forward pressure on the fiber in synchrony with the delivery of radiation pulses. An irradiation protocol suitable for producing such canals in cadaver porcine eyes was delineated using Ho:YAG, Nd:YAG, and diode laser energy sources. Despite significant differences in the pulse energy required for perforation (0.25, 7, and 8 J for the Ho:YAG, diode, and Nd:YAG lasers, respectively), the extent of collateral damage was comparable for each type of laser. The physical mechanisms underlying these findings are discussed.

Animals↗

Blood flow stasis induced by cw-Nd:YAG laser irradiation: comparative morphology of mesenteric and choroidal vessels in pigmented rabbits.

cw-Nd:YAG laser radiation was effective in producing blood flow stasis within arteries (35-40 microns in diameter) of pigmented rabbit mesentery (beam spot size: 80 microns; fluence: 2 x 10(4) J cm-2) and choroid (beam spot size: 200 microns; fluence: 6 x 10(2) J cm-2). However, the mechanism by which this was achieved differed in each case, and depended upon the energy absorbing structures present in the irradiated tissue. In non-pigmented tissue, such as the mesentery, haemoglobin represents the primary absorption centre, and the temperature attained within the vessel lumen (as inferred from morphological changes) is sufficient to denature plasma proteins, in particular fibrinogen, which consequently occlude the vessel lumen and arrest bleeding. In pigmented tissue, such as the choroid, melanocyte granules represent the primary absorption centre, which is thus shifted from the vessel lumen to the stroma. The temperature rise achieved within the vessel lumen is consequently lower, as evidenced by the absence of plasma protein denaturation. Blood flow stasis nonetheless occurs, but is triggered according to the normal haemostatic mechanism.

Animals↗

A comparison of unweighted and fluctuation-weighted indices (within the central 28 degrees of glaucomatous visual fields measured with the Octopus automated perimeter).

The main visual field indices of Flammer and the analogous ones of Heijl have been compared based on a population of 113 glaucomatous visual fields. It is shown that for the population studied, the differences between the two sets of indices are negligible for Octopus G1 program results and that they may thus be used interchangeably.

Glaucoma↗

The effects of weighting the "mean defect" visual field index according to threshold variability in the central and midperipheral visual field.

Two visual field indices, the mean defect (MD) of Flammer and the mean deviation (MD) of Heijl, have found wide acceptance among perimetrists. We compared these indices in 169 visual fields from normal- and high-tension glaucomatous eyes. Visual field damage in these eyes varied from slight to severe. In computations of the mean deviation index, the threshold values are weighted by the threshold deviations obtained from normal eyes as a function of eccentricity. However, the present study shows that the differences between the two indices in the population studied are negligible. Thus, subsequent interpretation is not affected by the choice of index, and the two MD indices may be considered to be interchangeable for the types of visual fields used in this study and for program-G1 examinations carried out using Octopus automated perimeters. Since we found smaller increases in local intersubjective fluctuations as a function of eccentricity in 274 normal visual fields as compared with results published by others, caution is indicated for interpretation of the visual field using probability weighting.

Humans↗

Evaluating a perimetric expert system: experience with Octosmart.

When evaluating expert systems to be used in clinical perimetry, various aspects of their performance as compared with that of human interpreters must be considered. In this investigation, the results produced by the new Octosmart diagnostic program have been compared with the performance of three interpreters with various amounts of experience in visual field analysis. The evaluations were based on 27 visual fields with glaucomatous damage, which had been examined with the Octopus program G1. It is shown that in borderline cases (i.e., neither clearly normal nor clearly pathological) where strict statistical criteria must be employed in order to distinguish between possible pathology and artifacts, the "personal styles" of human interpreters, more than standardized decision criteria, implicitly guide the decision process, resulting in unpredictable, non-standardized interindividual differences. A standardized expert system, based on constant, explicit, and logical criteria is therefore considered to be superior to unaided human interpretation. It is pointed out that the influence of the implicit decision criteria of human interpreters must be controlled carefully if expert systems are to be evaluated with reference to human interpreters.

Analysis of Variance↗

[Bruch's membrane and its significance for retinopexy following laser irradiation].

Retinopexy may be produced by either of two mechanisms following transpupillary irradiation of the retina with the Nd:YAG laser. Which of these mechanisms is operative will depend on the degree of disruption produced within the elastic component of Bruch's membrane. Small defects in the elastic component of Bruch's membrane are soon completely bridged by regenerated retinal pigment epithelium (RPE) cells. However, there is a risk of subretinal neovascularization in such defects. Large defects in the elastic component of Bruch's membrane are not completely bridged by regenerating RPE cells before proliferating Müller cells invade this region and spread from it, mushroom-like, within the choroid. In this case subretinal neovascularization does not occur. In the former instance (small defects) retinopexy is achieved by a process of interdigitation between the microvilli of Müller and RPE cells; and in the latter (large defects) via a press-stud-like anchorage of Müller cells within the choroid. It has not yet been established whether these two retinopexy phenomena, observed after irradiation of rabbit retinas, occur in the same way in man.

Animals↗

Evaluating human and automated interpretation of visual field data in perimetry.

The complexity of visual field result evaluation has increased with the advent of automated perimetry. This in turn makes software assistance such as provided by the new Octosmart program interesting and desirable. Its accuracy and reliability in visual field evaluation must be tested, though, and the testing methodology itself must be developed. For this purpose, 27 visual fields were evaluated by three human interpreters and the Octosmart program. Based on a newly developed compound index, the performance of the three interpreters and Octosmart is described and a high degree of consistency is demonstrated.

Diagnosis, Computer-Assisted↗

Transpupillary irradiation of the rabbit retina with the cw-Nd:YAG laser. I. Acute morphologic effects produced using two different pulse forms.

The retinas of six pigmented rabbits (12 eyes) were irradiated with a cw-Nd:YAG laser using two different pulse forms, in conjunction with a constant pulse duration of 200 msec and a retinal focus diameter of 200 microns. The first pulse form (a) was characterized by an initial transient, lasting 15-20 msec, with a peak power twice that of the ensuing plateau phase of 180-185 msec. The second pulse form (b) was almost rectangular in shape. Although the average energies (and powers) for each pulse form were identical, almost 20% of this entity was delivered within the first 20 msec for the first pulse form. Impact lesions were examined at the biomicroscopic, light, and electron microscopic levels, and the characteristic morphologic features described for the cw-mode in general. Comparison of the effects produced using each pulse form revealed a number of differences. At low pulse energies (less than 150 mJ) the rectangular pulse form produced a photocoagulation reaction within the outer sensory retina, but when using the pulse form with the initial transient, this effect was superimposed by a degree of mechanical disruption. Ruptures produced within the elastic component of Bruch's membrane first appeared at lower pulse energies (ie, at 75 mJ, as opposed to 150 mJ for the rectangular pulse form) and were more frequent, and choroidal macrohemorrhaging (observed at pulse energies greater than or equal to 200 mJ) occurred only, when this latter pulse form was employed. Each of these phenomena may be attributed to the higher power and energy densities attained during the initial transient, which has disruptive properties. In order to avoid the risk of severe bleeding, these irradiation parameters should be maintained below approximately 6.4 X 10(3) W/cm2 and approximately 0.13 X 10(3) J/cm2.

Animals↗

A new universal laser apparatus for intra and extraocular irradiation tasks in the eye.

We describe a universal laser apparatus for multipurpose clinical tasks. The main unit consists essentially of a Haag-Streit slit lamp combined with a rigidly mounted Q-switched laser. The apparatus is designed basically for performing photodisruptive tasks. Radiation emitted by either a pseudocontinuous cw Nd:YAG laser (with a dynamic range of 10 W) or by an air-cooled 4-W argon ion laser energy source either may be transmitted via fiber optics into the main unit or, when detached from the main unit, may be used independently. Energy emitted by the modules and transported by specialized light cables and delivery systems can be used to perform transscleral Nd:YAG laser irradiation of the ciliary body or the choroid and retina. Probes are available for endocoagulation of the latter two by either cw Nd:YAG or argon laser light. Other probes are being developed for chorioretinotomy, internal sclerostomy, dissection of the sclera, or for other extrabulbar work. All functions are monitored and displayed by a central processor.

Anterior Eye Segment↗

Puptrak 1.0--a new semiautomated system for pupillometry with the Octopus perimeter: a preliminary report.

A provisional, semiautomated version of a system for automated testing of the afferent pupillary reflex with perimetric methods under controlled conditions is described. The target projected onto the perimeter cupola is used as the stimulus for triggering the pupillary response. In a modification to the Octopus 201, the pupil is illuminated by two IR LED diodes, while the pupillary responses are recorded by the onboard IR sensitive TV camera built into the perimetric unit. Measurements of the pupillary area as a function of time and stimulus luminance have been performed and have resulted in consistent results. Here, one perimetric program, working with stimuli above the threshold for the afferent pupillary light reflex is described. The present setup works with system-specific software and standard hardware, the central data processing unit being a desk-top computer (IBM PC AT-03). The mating of an automated pupillary measuring unit to an automated perimeter may open the door for a more widespread evaluation of the value and the clinical application range of pupillary perimetry and may be of interest in other areas of visual and clinical psychophysics. The shortcomings of the present system, in particular insufficient temporal resolution and lack of full automation, are being removed at the present time.

Computer Systems↗