PubMed Health⌕ Search

Biomedical subjects

F Funck

Publications and source records attributed to F Funck.

At least 37 records · Page 2Linked to original sources

Direct stent implantation without predilatation using the MultiLink stent.

The standard coronary stent implantation technique requires routine predilatation of the target lesion with a balloon catheter. In this study, we prospectively studied the feasibility and efficiency of elective coronary stent implantation without predilatation. In 94 patients who presented with various ischemic syndromes, direct implantation of 100 balloon expandable ACS MultiLink stents (7 over-the-wire, 93 rapid exchange) was attempted in 100 coronary lesions selected to have favorable characteristics. The stent crossed the lesion without predilatation in 97 cases (97%) and was successfully deployed in 93 (95.8%). In 4 patients, adjunctive high-pressure postdilatation was necessary to achieve optimal stent expansion. Reference vessel diameter was 3.12+/-0.77 mm and lesion length 8.8+/-2.7 mm. Minimal luminal diameter increased from 0.95+/-0.38 mm to 2.98+/-0.28 mm and diameter stenosis decreased from 71+/-11% to 8+/-11% after stenting. One occlusive dissection was treated by a second stent. There were no major in-hospital complications. At 1 month follow-up, 1 subacute thrombotic occlusion occurred. These results indicate that in a carefully selected coronary lesion subset, elective stent implantation without predilatation can be safely and effectively performed. The long-term results of this approach and possible advantages over the conventional implantation techniques remain unclear and need to be evaluated in further clinical studies.

Aged↗

Preliminary clinical experience with the Bard XT coronary stent.

BACKGROUND: The Bard XT stent is a balloon expandable stent with a new design, consisting of discrete zigzag modules welded onto a flexible longitudinal spine. METHODS: To assess the safety and efficacy of this recently introduced coronary stent, we studied 81 patients (107 lesions) who underwent implantation of 108 such stents (66% elective). RESULTS: Primary success in stent delivery was 97.1% and angiographic success was achieved in all cases. Reference segment diameter was 2.69+/-1.4 mm and average lesion length 10.9 mm. Mean minimal luminal diameter before the procedure was 0.79+/-1.11 mm and increased to 2.55+/-1.09 mm after stenting. Diameter stenosis decreased from 76%+/-24% to 9%+/-12%. One Q wave and 1 non-Q-wave myocardial infarction occurred but no other significant complications were observed. At 1-month follow-up, angiographically documented subacute thrombosis occurred in 2 cases at days 1 and 3. Conclusions These preliminary data suggest that the Bard XT stent has a promising design for the safe and effective treatment of coronary lesions, even in the presence of high-risk clinical and unfavorable angiographic characteristics.

Aged↗

[Recurrent bronchogenic cyst with rupture into the pericardium. A case report].

A case of tamponnade due to intrapericardial rupture of a recurrent bronchogenic cyst, presenting as pericarditis, is described. This case is unique because it demonstrates the possibility of rupture of a bronchogenic cyst into the pericardium and by the unusual mode of presentation. It also shows that bronchogenic cysts may recur many years after incomplete ablation. Bronchogenic cysts are benign dysembrioplasic formations characterised by their respiratory epithelial lining. The usual presentation in the adult is by haemorrhage or infection, but our case shows that recurrent pericarditis without an obvious cause may be due to bronchogenic cyst, which should be systematically excluded. The diagnosis suspected after medical imaging (chest X-ray, scanner, magnetic resonance imaging) is confirmed by histology. Total surgical ablation is the treatment of choice and may be curative.

Adult↗

[Single coronary artery arising from the right coronary sinus. Report of two cases].

The authors report two cases of single coronary artery arising from the right coronary sinus. Both patients had angina with reversible myocardial ischaemia on exercise Thallium scintigraphy. Coronary angiography showed single coronary artery arising from the right coronary sinus in both cases with severe stenosis of the right coronary artery in the first and occlusion of the right coronary artery in the second patient. Both underwent surgical revascularisation with a good result. Single coronary artery is a rare congenital abnormality (approximately 0.36 per 1,000) diagnosed at autopsy until 1963, and thereafter at coronary angiography. A review of the literature shows that an equal number of single coronary arteries arise from the right as from the left coronary sinus: there does not seem to be an increased risk of complication when a branch runs between the aorta and pulmonary artery. On the other hand, single coronary arteries arising from the right coronary sinus seem to be more commonly associated with atherosclerosis than a network with two coronary arteries, but when the lesions are proximal, the risk is high. Revascularisation is indicated only when myocardial ischaemia has been documented.

Aged↗

[Comparative study of cibenzoline and flecainide by oral route for preventing recurrence of paroxysmal atrial tachyarrhythmias].

Although paroxysmal atrial arrhythmias are the commonest form of arrhythmia, their therapeutic management still remains controversial. Seventy one patients were included in a multicentre, randomized double-blind, double-placebo study, in parallel groups (37 in group C and 34 in group F) to compare the efficacy of cibenzoline (C) and flecainide (F), administered orally, in the prevention of recurrent atrial arrhythmia. The arrhythmia usually consisted of atrial fibrillation (n = 65), while 6 patients presented with paroxysmal atrial flutter. The mean daily dosages were 221 +/- 60 mg (C) and 165 +/- 49 mg (F). The mean age was 63 +/- 12 years in group C and 63 +/- 16 years in group F. In this trial, atrial arrhythmia was idiopathic in almost two-thirds of cases. The duration of follow-up of this study was 6 months, during which recurrences of arrhythmia were evaluated in terms of the symptoms experienced and in terms of ECG and Holter examinations repeated at the 3rd and 6th months. Supplementary ECG and Holter examinations were also performed in the presence of a clinical suspicion of recurrent symptoms. Comparison of the percentages of patients not developing a documented recurrence and who tolerated treatment, by Kaplan-Meler curves, showed a significant difference between cibenzoline (58%) and flecainide (56%). In the not-responders, the mean time to recurrence was 75 +/- 48 days in group C and 75 +/- 62 days in group F(NS). Six patients dropped out of the trial because of adverse events, including 3 cardiac adverse events (2 case of ventricular proarrhythmic activity). Four extracardiac adverse events led to discontinuation of treatment in group C. In conclusion, the efficacy of cibenzoline and flecainlde in the secondary prevention of atrial arrhythmia was found to be comparable, with 58% and 58% of patients in sinus rhythm, respectively, with a follow-up of 6 months.

Anti-Arrhythmia Agents↗

[Coronary angiography by left radial approach. A bi-center prospective pilot study].

The aim of this study was to assess prospectively the feasibility, safety and quality of coronary angiography performed by a left radial arterial approach. The investigation was performed under local anesthesia with a Lidocaine gel using Judkins 5f catheter. A bolus of heparin was injected intravenously at the start of the procedure (no heparin in phase 0.2 to 3.000 IU during phase 1 and 5.000 IU in phase 2). Between March 1994 and January 1996, after exclusion of 108 patients (15.1%) mainly because of an abnormal Allen test, coronary angiography was carried out in 540 patients aged 58.4 +/- 11.7 years, 85% of whom were men. The failure rate was 8%. The quality of opacification of the left coronary artery (scale 1 to 3) was 2.91 +/- 0.27 and of the right coronary artery was 2.96 +/- 0.18. There were no complications during the procedure. Analysis of the learning curve showed a failure rate decreasing to less than 5% after 60 procedures/operator. In the last 100 procedures, the failure rate fell to 3%, the canulation time was 2.2 +/- 2.5 min, the duration of fluoroscopy was 6.5 +/- 3.9 min and the duration of the procedure was 17.5 +/- 4.7 min (14.7 +/- 3.8 min, p < 0.01, by the femoral approach). Clinical and Doppler ultrasonographic follow-up revealed one in-hospital complication (a spontaneously regressive compressive haematoma). No clinical complications were observed at 3 months. Doppler ultrasonography showed the radial artery occlusion rate to be 71% in phase 0.32% in phase 1 and 3.2% in phase 2 (p < 0.0001). These results show that the left radial arterial approach for coronary angiography is safe and effective but requires a period of training. A 5.000 IU dose of heparin limits the risk of radial artery occlusion to 3%. The absence of complications in this large series which included the training period and the patient comfort suggest that this technique may be an excellent alternative to the femoral approach and especially the brachial approach when the Allen test is normal.

Aged↗

[Isolated left ventricular muscular diverticulum in an adult. Value of non-invasive examinations].

The authors report a case of ventriculum in a 45 year old women investigated for chest pain. This was a congenital muscular left ventricular diverticulum confirmed by a complete imaging series including echocardiography, magnetic resonance imaging, angio-scintigraphy and conventional angiography. This diverticulum was unusual due to the fact that there was no associated congenital disease and that it was discovered in an adult. The authors review the literature and discuss the value of non-invasive imaging procedures.

Angiocardiography↗

[Management of myocardial infarction in patients over 75 years of age compared to patients under 75 years of age. Apropos of 594 consecutive cases admitted between 1991 and 1994].

This study analyses the patients consecutively admitted for myocardial infarction between January 1991 and December 1994. The study population consisted of 594 patients divided into two groups: 446 patients under the age of 75 years and 178 patients over the age of 75 years. The sex-ratio showed a male predominance (84%) before 75 years, and a female predominance (57%) after 75 years. A history of angina was more frequent in elderly patients (45% vs 30%, p < 0.001), who were admitted later (22.5% vs 46.6% before the 6th hour, p < 0.001). Thrombolysis was administered in 49.6% of subjects under the age of 75 years and in 17.3% of elderly patients. The course was uneventful in 56.7% of subjects under the age of 75 years and in 28.2% of elderly patients. Mortality was 6-fold higher in this group (22% vs 3.7%, p < 0.01). The cause of death was usually heart failure with a 10-fold higher frequency of cardiogenic shock (13.5% vs 1.4%, p < 0.001). Coronary angiography was performed in 81.4% of subjects under the age of 75 years and in 30% of the elderly patients. Multi-vessel lesions were more frequent in elderly subjects (78.4% vs 47.5%, p < 0.01). Revascularization by angioplasty or bypass graft was performed with a similar frequency (50%) in the two groups of patients investigated by coronary angiography. The mortality of myocardial infarction was high in the elderly, usually due to heart failure, and partly explained by the severity of the coronary lesions; in contrast, elderly patients were less frequently submitted to active management (thrombolysis-coronary angiography), while recent data of the literature argue in favour of primary angiography in these patients.

Aged↗

Evaluation of a new 9F guiding catheter for directional coronary atherectomy.

Large lumen guiding catheters (9.5 to 11 French) are currently required to perform directional atherectomy. These rigid guiding catheters require modifications of usual techniques for manipulation and can induce ostial trauma and peripheral vascular complications. A new type of 9 French guiding catheter (Vista Brite tip, Cordis, Miami, FL) with an inner diameter of 0.098 inch and capable of accomodating atherectomy catheters (SCA-EX) was evaluated. In this preliminary study, 31 consecutive patients were included. Primary success was obtained in 27 (87%); no ostial trauma and only two minor groin hematomas were observed. After exchange with a conventional 10F guiding catheter, because of poor back-up, two of the four failures were successfully treated by DCA. In conclusion, these new 9F guiding catheters provide a useful alternative to currently available guiding catheters for DCA. Nevertheless, new shapes with better back-up are necessary to improve the primary success rate.

Adult↗

Left radial approach for coronary angiography: results of a prospective study.

Although radial approach has been shown to be feasible for coronary angiography, angioplasty, and even stent placement, there have been no prospective evaluations of ease and safety of left radial approach for coronary angiogram. We examined procedural duration and success as well as complications in 415 consecutive patients. Radial artery occlusion was assessed immediately post-procedure and at 2 month follow-up using echo-Doppler measurements. Procedure failure rate was 9%, mean time for sheath insertion was 4.7 +/- 4.7 min, and mean procedure duration was 19.1 +/- 8.2 min. No major complications occurred. Asymptomatic radial artery occlusion was noted in 71% of the first 49 patients, decreased to 24% in the next 119 receiving 2,000-3,000 units of heparin, and to 4.3% in the last 210 receiving 5000 (p < 0.05). Comparison with the femoral approach in the same laboratory suggested that the radial approach took longer, but provided similarly high-quality results without great difficulty in coronary cannulation. Hence, the left radial approach for coronary angiography (with heparin administration) allows immediate ambulation and may be especially useful for outpatients and when the femoral approach is not possible.

Aged↗

Rotational atherectomy with adjunctive balloon angioplasty versus conventional percutaneous transluminal coronary angioplasty in type B2 lesions: results of a randomized study.

A randomized pilot study was performed comparing conventional balloon angioplasty (percutaneous transluminal coronary angioplasty [PTCA] group) and rotational atherectomy (RA) with a medium size burr (50% to 70% burr/artery ratio) with systematic adjunctive balloon angioplasty (RA group) in type B2 stenosis. A total of 64 patients were included. Primary success was 93.7% in the RA group and 87.5% in the PTCA group (p = NS). Technical failure with no complication occurred once in each group. Acute complications occurred in three patients in the PTCA group and in one in the RA group. Angiographic restenosis rates were similar (RA group: 39%, PTCA group: 42%, p = NS) with a follow-up rate of 93%. In type B2 lesions, when compared with conventional angioplasty, RA with systematic balloon angioplasty does not seem to increase procedural success, and the restenosis rate remains comparable. However, these results must be confirmed in a larger series of patients.

Aged↗

Can we optimize our angiographic views every time? Qualitative and quantitative evaluation of a new functionality.

RATIONALE AND OBJECTIVES: For determining the optimum angulations of the x-ray beam with respect to the vascular morphology of a given patient, the authors present a solution combining a single-plane angiographic system and a dedicated procedure. METHODS: The clinical evaluation of the vessel profiling acquisitions focuses on qualitative appraisal and quantitative analysis of conventional and optimum projections. RESULTS: The qualitative evaluation demonstrates the pitfall for an operator to discern optimum from conventional projections. The 70% of preferences for vessel profiling bear witness to the constraints imposed occasionally by the optimum angulations, which may be impracticable for various reasons. However, vessel profiling yields lesions inspection at an optimum view, free of geometric foreshortening. Moreover, there is less risk of superimposition with other branches. From a quantitative standpoint, vessel profiling unveils the lesion with a length significantly longer than in conventional view. CONCLUSIONS: Vessel profiling offers a qualitative optimization of angiographic images and more exact quantitative analysis.

Angiocardiography↗

Safety and efficacy of the new iodinated nonionic low-osmolality contrast medium Iobitridol (Xenetix) in coronary and ventricular angiography.

PURPOSE: The aim of this phase-III clinical trial was prospectively to evaluate the clinical safety and diagnostic efficacy as well as the effects on laboratory and electrocardiographic parameters of new iodinated, nonionic, low-osmolality contrast medium, iobitridol(Xenetix 350) during coronary angiography in adults in comparison to an iodinated, nonionic, low-osmolality reference product, iohexol (Omnipaque). MATERIALS AND METHODS: This 2-center, comparative, randomized, double-blind trial involved 90 patients, 46 receiving iobitridol and 44 iohexol. Clinical safety was evaluated by recording the adverse events observed during investigation and by the patient's assessments. Electrocardiographic effects on laboratory parameters were evaluated as well as diagnostic efficacy. RESULTS: The age, sex, presence of risk factors and clinical picture ( unstable angina, postinfarction) were not significantly different between the 2 treatment groups. The incidence of significant coronary lesions (stenosis 50%) was also not significantly different between the 2 treatment groups. Clinical safety was good in both groups. Four patients experienced an adverse event, 2 in each group. In the iobitridol group, one patient had an episode of hypertension, followed by hypertension and prolonged chest pain was observed and one patient had sinus tachycardia. In the iohexel group, chest pain was observed in one patient and nausea in another. ECG safety was good in both groups. Transient excitability disorders were observed in 10 and 6 patients, respectively. Moderate conduction abnormalities were noted in one patient in each group and repolarization abnormalities in 10 and 8 cases, respectively. Safety in laboratory parameters was good with no significant changes in either. Diagnostic efficacy was good to excellent in all patients. CONCLUSION: Diagnostic efficacy and safety of iobitridol 350 in terms of effects on clinical, laboratory and electrocardiographic parameters were comparable to those of the nonionic reference product.

Contrast Media↗

[Optimization of coronary angiographic views. Qualitative and quantitative evaluation of a new system].

A coronary angiographic view is said to be "optimal" when the directing radius of the X-ray beam is perpendicular to the long axis of a stenosis. The object was to fulfill two criteria: 1) the accurate calculation of the spatial orientation of the stenosis to obtain the optimal position, 2) rapid and optimal positioning of the angiographic material with easy rotation around the axis of the stenosis. Two combined solutions were proposed:the Advantx L/C (GE Medical systems) angiocardiographic system with three motorised axes of rotation and a specific software. This software takes into account two longitudinal axes of the stenosis traced by the operator in two conventional incidences and then determines the angles of optimal positioning (accuracy +/-5 degrees). During 97 consecutive coronary angiograms, the software was used in 23 cases (24%) and judged to be useful in 16 cases (70%). In 2 of the 23 cases (8%) the mechanical angles calculated could not be used, the incidences being incompatible with the patient's position. During the angiograms, the best two images of stenosis (one conventional, one optimal) were retained to form a pair of images. Eight observers analysed 37 pairs of images shown side by side. 65% of the images selected from each pair as being the best descriptive appearance of the stenosis came from the optimised system. During quantitative analysis, only the length of stenosis differed statistically between the two modes of acquisition (1.26 +/- 0.36 mm; p = 0.0014). This system is useful during coronary angiography for providing optimal views of stenosis free from any geometric distorsion and without superimposition of adjacent branches.

Coronary Angiography↗

[Coronary angioplasty combining rotational atherectomy and balloon dilatation. Results in 67 complex stenoses].

The treatment of complex coronary stenoses by conventional angioplasty is limited by a relatively low angiographic success rate, associated with a high risk of major complications. The role of new angioplasty techniques in the treatment of these lesions has not yet been determined. The aim of this prospective study was to evaluate the systematic association of rotational atherectomy (Rotablator) with balloon angioplasty on coronary stenoses characterised by at least 2 type B criteria of the ACC/AHA classification (type B2 lesions). The procedures was begun with rotational ablation with a medium-sized burr (50 to 70% of the reference diameter of the artery) and completed systematically by balloon angioplasty (balloon/artery ratio = 1), using the lowest possible inflation pressures for successful dilatation. This technique was used in 61 patients who had 67 coronary stenoses with a primary success rate (residual stenosis < 50% and no major complications) of 93.4% (57 patients). One emergency coronary bypass procedure was necessary and another patient developed transmural infarction on the 3rd day after the procedure. There were two technical failures (3.3%). The mean inflation pressure of the balloon was 4.1 +/- 1.2 atmospheres. There were no fatalities. During atherectomy, transient conduction defects were observed in 4 patients (6.6%): severe hypotension in 2 patients (3.3%) and complete spasm in 3 stenoses (4.5%). A significant increase in cardiac enzyme levels was observed in 4 patients (6.6%). The authors conclude that rotational atherectomy with a medium-sized burr, followed by systematic low pressure balloon dilatation allows treatment of certain complex coronary stenoses with a high primary success rate and few major complications.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

[Thrombolysis and massive pulmonary embolism: occasionally spectacular results].

The authors report the clinical history of a 47-year-old patient hospitalised as an emergency with acute respiratory distress complicated by cardiocirculatory arrest. The diagnosis of pulmonary embolism was rapidly suspected and confirmed by emergency pulmonary angiography. A definite diagnosis enabled the early prescription of fibrinolytic treatment in situ. The interest of this case lies essentially in demonstration of the efficacy of fibrinolytic treatment which enabled the rapid restoration of a stable hemodynamic status and normalisation of angiographic appearances within a few days.

Acute Disease↗

[Recurrent syncope during deglutition. An uncommon form of sinusal dysfunction].

The authors report the case of a 69 year old man with a 16 year history of syncope occurring only while swallowing liquids. Two episodes were observed during a hospital admission to the intensive care unit for unstable angina and allowed documentation of prolonged sinus arrest (7 sec) causing syncope. In the light of this case and a review of the literature, the physiopathological role of deglutition in the genesis of cardiac conduction defects and arrhythmias is discussed and the new classification of sinus node dysfunction proposed by Bashour in 1985 is recalled.

Aged↗