Prescribing dialysate bicarbonate concentrations for hemodialysis patients.

A rearranged equation of Sargent and Gotch (1) was used to determine dialysate bicarbonate concentrations for hemodialysis patients. Parameters in this equation include an estimate of the acid generated by each patient between treatments, an estimate for the dialyzer dialysance for bicarbonate, ultrafiltration rate, blood flow rate and a targeted mid-dialysis plasma bicarbonate concentration of 25 mEq/L. Nine patients were studied over a 35 week period to verify this method of determining each patient's dialysate bicarbonate concentration. Prescribed dialysate bicarbonate concentrations for the nine patients varied from 29 to 38 mEq/L with five patients having a prescribed value of 35 mEq/L. After a baseline period of five weeks, five patients switched from a 37 mEq/L acetate dialysate to their prescribed dialysate bicarbonate concentration. Four patients who had already been on bicarbonate dialysis at a concentration of 35 mEq/L were dialyzed with their prescribed dialysate bicarbonate concentrations. Patients were then followed for a study period of 30 weeks. The prescribed dialysate bicarbonate concentration resulted in more normal acid/base chemistries for both groups of patients. The results also demonstrate that chronic hemodialysis patients require individualization of dialysate bicarbonate concentrations.

Acid-Base Equilibrium↗

Oxygen exchange in silicone rubber capillaries.

Capillaries of 7 and 12.5 mu diameter have been fabricated in silicone rubber. Whole blood treated with heparin has been perfused through these capillaries. Under flowing conditions, no clotting or other clumping effects have been observed and red cells appear to maintain a constant velocity. Oxygen transfer data to and from saline perfusing the 12.5 mu diameter capillaries have been obtained in order to determine how rapidly O2 will permeate the silicone rubber film. The data indicate that the capillaries simulate lung tissue oxygen exchange and will allow for the first time the experimental determination of oxygen exchange kinetics in flowing whole blood.

Blood Flow Velocity↗

Calculations for pH during CO2 and O2 exchange with blood.

New mathematical formulas are presented to calculate directly the change in blood pH during CO2, and O2 exchange with blood. pH changes are calculated from changes in blood PCO2 and saturation values or from changes in blood PCO2 and blood PO2 values. Computational results agree well with information obtained from a Dill nomogram. These new formulas have applicability to the modelling of gas exchange in blood oxygenators as well as to estimating blood acid-base parameters following the mixing of blood samples.

Blood↗

Plasma volume nomograms for use in therapeutic plasma exchange.

Nomograms have been developed for the convenient estimation of the plasma volumes of patients undergoing therapeutic plasma exchange (TPE), based on equations employing height, body weight, and hematocrit. These nomograms are offered as an aid to prescribing continuous-flow TPE procedure exchange volumes.