PubMed Health⌕ Search

Biomedical subjects

F G Mihm

Publications and source records attributed to F G Mihm.

At least 37 records · Page 2Linked to original sources

The effects of prostaglandin E1 on the adult respiratory distress syndrome in septic primates.

The effects of prostaglandin E1 (PGE1) on the adult respiratory distress syndrome were studied in the septic primate (Macaca fascicularis). A 30-min infusion of Escherichia coli (1 X 10(10)/kg) resulted in severe septic shock and adult respiratory distress syndrome. Primates, if living, were killed 4 h after completion of the E. coli infusion. Three groups of primates were studied (n = 4 in each group). The control group (Group 1) received PGE1 at 100 ng/kg/min throughout the experiment. The septic group (Group 2) received a 30-min infusion of E. coli. The treatment group (Group 3) received a continuous PGE1 infusion (100 ng/kg/min) along with the E. coli infusion which was begun 30 min after the PGE1 infusion was started. Control primates had hemodynamic changes consistent with the vasodilatory effect of PGE1 (heart rate and cardiac output increased; blood pressure and systemic vascular resistance (SVR) decreased). All control animals survived the experiment and had no evidence of pulmonary damage. Primates given E. coli developed severe hypotension, decreased SVR, and lung injury evidenced by pulmonary edema, decreased oxygenation, and increased extravascular lung water. Primates treated with both PGE1 and E. coli developed similar cardiovascular and pulmonary changes as the septic group. There was no statistically significant difference between Group 2 and Group 3 animals with regard to mean arterial blood pressure, SVR, extravascular lung water, alveolar-arterial oxygen difference, or survival.(ABSTRACT TRUNCATED AT 250 WORDS)

Alprostadil↗

Effects of anti-C5a antibodies on the adult respiratory distress syndrome in septic primates.

In vitro and in vivo studies have suggested that human complement component C5a plays a key role in neutrophil injury in the adult respiratory distress syndrome (ARDS). First, using leukocyte aggregometry, we demonstrated that the addition of a recently developed rabbit anti-human polyclonal antibody to C5a des arg to endotoxin-activated plasma prevented leukocyte aggregation in vitro. We then administered the anti-C5a des arg antibody to septic primates (Macaca fascicularis). Three groups of primates, control, septic, and anti-C5a antibody treated septic, were studied (n = 4 in each group). A 30-min infusion of Escherichia coli (1 X 10(10)/kg) resulted in severe sepsis and ARDS. Primates were killed 4 h after completion of the E. coli infusion. Septic animals not treated with anti-C5a antibody had 75% mortality (3/4), decreased oxygenation, severe pulmonary edema, and profound hypotension. Septic primates treated with anti-C5a antibodies did not die and did not develop decreased oxygenation (P less than 0.05) or increased extravascular lung water (P less than 0.05). They also had a marked recovery in their mean arterial blood pressure (P less than 0.05). This study demonstrates that treatment with rabbit anti-human C5a des arg antibodies attenuates ARDS and some of the systemic manifestations of sepsis in nonhuman primates.

Animals↗

Thermodilution cardiac output measurement. Effects of the respiratory cycle on its reproducibility.

Thermodilution cardiac output measurements are commonly employed in the management of critically ill patients. Serial measurements often show significant variation, and poor reproducibility limits their clinical utility. There are no clinical studies revealing when to perform thermodilution cardiac output measurements in relation to the respiratory cycle. We prospectively studied 32 patients in a randomized scheme comparing three thermodilution cardiac output measurements at peak-inspiration, at end-exhalation, or randomly in spontaneously breathing and mechanically ventilated patients. Saline injections initiated at peak-inspiration or end-exhalation resulted in cardiac output measurements with much smaller standard deviations than those seen with random injections. Thermodilution cardiac output measurements performed at random times in the respiratory cycle should be avoided, and we recommend initiating these measurements at end-exhalation.

Cardiac Catheterization↗

The effect of hypothermic preservation of the heart and lungs on cardiorespiratory function following canine heart-lung transplantation.

The effect of hypothermic preservation of the heart and lungs with a crystalloid solution was evaluated in 12 mongrel dogs receiving heart-lung allografts. Six animals served as controls and received an immediate heart-lung transplant. Six animals were in the experimental group and received a heart-lung transplant after 5 hours of preservation at 4 degrees C following perfusion of both organs with a crystalloid solution. Physiological function of the heart and lungs was studied for 20 hours after transplantation. While cardiac function was minimally depressed following preservation, pulmonary function testing demonstrated significantly greater increases in extravascular lung water in experimental animals, suggesting that an ischemic lung injury occurred with this preservation technique. The model allows for future evaluation of other methods of combined preservation of both the heart and lungs for transplantation.

Airway Resistance↗

Failure of the colloid oncotic-pulmonary artery wedge pressure gradient to predict changes in extravascular lung water.

Colloid oncotic pressure (COP), pulmonary artery wedge pressure (WP), and the COP-WP gradient were measured in seven critically ill adult patients and compared with extravascular lung water determined using the thermal-dye double-indicator dilution technique and a bedside lung water computer. Correlation coefficients for changes in extravascular lung water vs. COP, WP, and COP-WP were not significant, and in this patient population the COP-WP gradient did not predict changes in extravascular lung water.

Adult↗

Evaluation of the portable chest roentgenogram for quantitating extravascular lung water in critically ill adults.

The diagnosis of pulmonary edema is frequently made from characteristic findings on the chest roentgenogram that suggest an increase in lung water. Optimal radiographic technique depends on a cooperative upright patient, which is not possible with most critically ill patients. These patients may also have multiple radiographic abnormalities that make interpretation of the chest roentgenogram difficult. The ability of portable chest roentgenograms to accurately identify the presence of excess lung water and monitor changes in lung water has not previously been evaluated in critically ill adults who are intubated and ventilated and in the supine position when the films are exposed. In 12 patients the pulmonary edema seen on portable chest roentgenograms was given a score (0 to 390 points), which was then compared with a determination of extravascular lung water using the thermal-dye indicator dilution technique. A linear correlation was observed (r = 0.51; p less than 0.05; n = 73). Evaluation of a change in radiographic score vs a change in lung water showed no linear correlation (r = 0.1; p greater than 0.05). While portable chest roentgenograms exposed under the conditions described were a useful technique for demonstrating pulmonary edema, they were not accurate in monitoring modest changes in lung water in critically ill patients.

Adult↗

Inhibition of thrombus formation on intravascular sensors by electrical polarization.

Implantable biomedical sensors built on a silicon substrate capped with glass are currently being developed for intravascular applications. Electrical techniques for inhibiting thrombus formation on the surface of a proposed optical sensor in direct contact with blood have been investigated. Glass-on-silicon specimens (4 X 1.2 X 0.4 mm3) were coated with indium-tin oxide, a transparent conductor, and implanted in the vena cava and iliac veins of three dogs for 10, 20, or 33 days. The equilibrium surface-blood interface potentials of the specimens were modified by implanted current sources which supplied either direct current (8-15 microA) or 100 KHz alternating current (5 microA, root mean square). Light-microscopic and scanning electron-microscopic analyses showed each of the DC-polarized specimens to be free of thrombus, in contrast to nonpolarized (control) specimens on which varying amounts of adsorbed protein and thrombus deposits were found. Like the control specimens, the AC-polarized specimens formed thrombus, but the appearance of the deposits differed. These findings support the view that the polarity, magnitude and time dependence of the potential across conducting surface-blood interface significantly influence thrombogenicity. Further work is necessary to determine the roles of electrochemical and electrostatic factors in preventing thrombus formation on foreign materials.

Animals↗

Monitoring end-tidal carbon dioxide tensions with high-frequency jet ventilation in dogs with normal lungs.

The end-tidal carbon dioxide tension (PetCO2) measured after a single, large tidal-volume breath (15 ml/kg body weight) was compared to simultaneous measurements of PaCO2 in 6 dogs with normal lungs who were receiving high-frequency jet ventilation (HFJV). There was an excellent linear correlation between PetCO2 and the PaCO2 over the entire range of CO2 tensions commonly encountered in clinical practice (PetCO2 = 0.9 PaCO2 + 2.2 torr; n = 51, r = .98, p less than .001, range of PaCO2 = 12-72 torr). We conclude that when lung function is normal, a simple system of measuring PetCO2 after a large breath is an accurate method of monitoring the effectiveness of CO2 elimination during HFJV.

Animals↗

Measurement of extravascular lung water in dogs using the thermal-green dye indicator dilution method.

The measurement of extravascular lung water by a double-indicator dilution technique using cold indocyanine green dye was evaluated in dogs. Pulmonary edema was induced in 11 animals by volume overload; 12 animals served as controls. For each measurement, the two indicators (cold dye) were injected into the superior vena cava and detected in the femoral artery. The extravascular thermal volume was calculated using the mean transit times of the two indicator curves. Pretermination measurements of extravascular thermal volume correlated closely with standard gravimetric analysis of pulmonary extravascular tissue weight (EVTV - 1.15 PEW + 2.1 ml/kg, n = 21, r = 0.97, P less than 0.001; where EVTV = extravascular thermal volume and PEW = pulmonary extravascular tissue weight). Throughout the experiment, the arterial oxygen tension and alveolar-arterial oxygen tension gradient, correlated poorly with EVTV (linear correlation: r = 0.47, 0.45, respectively). The intrapulmonary shunt correlated better with EVTV (r = 0.72). Nonlinear correlation of EVTV with intravascular pressures (left ventricular filling pressures, colloid oncotic pressures, and the pulmonary artery occlusion pressure-colloid oncotic pressure gradient) were more significant than linear relationships. The critical pressures at which lung water rapidly increased in this model occurred at left ventricular filling pressures of 22-27 mmHg and at pulmonary artery occlusion pressure-colloid oncotic pressure gradients of 25-30 mmHg. The thermal dye technique appears to provide an accurate measurement of lung water changes in this pressure edema model.

Animals↗

Prolonged toxicity of organophosphate poisoning.

A case of poisoning with a new organophosphate (fenthion) is reported in which the initial cholinergic crisis was delayed 5 days and recurred 24 days after ingestion. Psychosis was a persistent and sometimes singular manifestation. Because of the high lipid solubility of this pesticide, toxin analysis of repeated fat biopsies was an essential component of the management of this patient.

Adipose Tissue↗

Effect of graded administration of PEEP on lung water in noncardiogenic pulmonary edema.

The effect of graded application of positive end-expiratory pressure (PEEP) was studied in 10 mongrel dogs with pulmonary edema induced by oleic acid infusion. Six animals received progressive increases in PEEP (5 cm H2O) 120 min after the injection of oleic acid. These animals were compared to 4 control animals who did not receive PEEP. We found no difference between the 2 groups in lung water measured by a double indicator dilution technique during PEEP application. Lung water determined by gravimetric analysis was also not different between groups at the end of the experiment. PEEP did result in significant reductions in shunt fraction and alveolar-arterial oxygen tension difference suggesting that PEEP improves gas exchange in pulmonary edema by increasing lung volume, but not by altering lung water accumulation.

Animals↗