The safety of MRI.

Explore the source record for details and available documents.

Body Temperature↗

Exposure to a 1.5-T static magnetic field does not alter body and skin temperatures in man.

The literature has conflicting reports concerning the effect of static magnetic fields on body and skin temperatures in mammals. Since temperature changes induced by static magnetic fields would have important safety implications for clinical magnetic resonance imaging body (sublingual pocket) and skin (abdomen, forehead, chest, upper arm, forearm, thigh, and calf) temperatures were determined in six normal subjects using a fluoroptic thermometry system during a 20-min exposure to a 1.5-T static magnetic field. Ambient conditions were controlled and held constant. An analysis of variance for repeated measures revealed that there were no statistically significant changes in body or any of the skin temperatures recorded. We conclude that exposure for 20 min to a 1.5-T static magnetic field does not alter body and skin temperatures in man.

Air Movements↗

Patellar tracking abnormalities: clinical experience with kinematic MR imaging in 130 patients.

A kinematic magnetic resonance (MR) imaging technique for assessment of malalignment of the patella, involving the acquisition of multiple sequential axial images of the patellofemoral joint during the early increments of passive knee flexion, was used to evaluate 130 patients (235 symptomatic patellofemoral joints) showing clinical evidence of having patellar tracking abnormalities. Twenty-three of the patellofemoral joints had undergone previous surgical procedures for patellar realignment. In addition, 14 (28 patellofemoral joints) asymptomatic control subjects were studied. Normal patellar tracking was observed in all of the asymptomatic subjects and in 43 (17%) of the 260 patellofemoral joints in the patient population, 18 (7%) of which were symptomatic. Sixty-nine (26%) of the patellofemoral joints had lateral subluxation of the patella, 106 (41%) had medial subluxation of the patella, 21 (8%) had excessive lateral pressure syndrome, 19 (7%) had lateral-to-medial subluxation of the patella, and two (1%) had dislocation of the patella. Of the 235 patellofemoral joints with suspected abnormalities, 217 (93%) had patellar malalignment. Of the 23 patellofemoral joints that had undergone prior surgery, 20 (87%) had abnormal patellar tracking. Thirteen of 14 (93%) patellofemoral joints that had undergone a prior arthroscopic lateral retinacular release had a medially displaced patella.

Adult↗

Alterations in body and skin temperatures caused by magnetic resonance imaging: is the recommended exposure for radiofrequency radiation too conservative?

Increases in tissue temperature caused by exposure to radiofrequency (RF) radiation are a primary safety concern of magnetic resonance imaging (MRI). Therefore, body and skin temperatures were measured in six subjects before (20 min), during (30 min) and after (20 min) MRI procedures performed at specific absorption rates (SARs) six to 10 times higher than the limit recommended by the UK National Radiological Protection Board. Body temperature was unchanged throughout the experiment. Abdominal skin temperature increased significantly (p less than 0.05) during MRI, decreased significantly post-MRI, but was still significantly (p less than 0.05) higher than baseline. The highest abdominal skin temperature recorded was 36 degrees C. Upper arm, forearm and chest skin temperatures increased significantly (p less than 0.05) during MRI and remained elevated post-MRI. The highest skin temperatures recorded on the upper arm, forearm and chest were 38.1, 36.0 and 34.5 degrees C, respectively. Thigh and calf skin temperatures were not significantly changed during MRI. These alterations in tissue temperatures were physiologically trivial and easily tolerated by the subjects, suggesting that the recommended exposure to RF radiation during MRI of the body for patients with normal thermoregulatory function may be too conservative.

Abdomen↗

Corneal temperature changes induced by high-field-strength MR imaging with a head coil.

High-field-strength/high-frequency magnetic resonance (MR) imaging systems can cause tissue heating. Since the eye is particularly susceptible to temperature elevations because of its relatively poor blood supply, the authors measured corneal temperatures in 33 patients immediately before and after MR imaging performed with a 1.5-T (64-MHz) imager and a transmit/receive head coil at estimated peak specific absorption rates (SAR) ranging from 2.54 to 3.05 W/kg. There was a statistically (P less than .001) significant increase in the average corneal temperature (32.7 degrees C +/- 0.7 before imaging, 33.2 degrees C +/- 0.5 after). The changes in corneal temperature ranged from 0.0 degrees C to 1.8 degrees C (mean, 0.5 degrees C), and the highest corneal temperature measured after imaging was 34.4 degrees C. In animal models, the eye temperature threshold for radio frequency-induced cataractogenesis is between 41 degrees C and 55 degrees C. The authors conclude that clinical MR imaging with use of a head coil at the SARs studied causes relatively minor increases in corneal temperature that do not appear to pose any thermal hazard to ocular tissue.

Adolescent↗

Patellofemoral joint: kinematic MR imaging to assess tracking abnormalities.

The patellofemoral joint was imaged with magnetic resonance (MR) in the axial plane while the knee was positioned from 0 degrees to 32 degrees of flexion (nine positions). These multiple sequential images obtained within the early phases of flexion of the knee were viewed in a "cine-loop" format, producing a kinematic study that clearly demonstrated the relationship of the patella to the trochlear groove. Four healthy subjects and one patient with known bilateral subluxing patellae were studied. The preliminary results suggest that kinematic MR imaging of the patellofemoral joint is potentially useful for the evaluation of patellar tracking abnormalities.

Adult↗

High-field-strength MR imaging and metallic biomedical implants: an ex vivo evaluation of deflection forces.

Ferromagnetic biomedical implants are considered a contraindication for MR imaging primarily because of the potential hazards associated with their movement or dislodgment. Many metallic biomedical implants are composed of nonferromagnetic materials and do not present a danger to patients during MR imaging. Therefore, to evaluate the ferromagnetic qualities of 36 different metallic biomedical implants (four aneurysm clips, six hemostatic clips, four dental implants, seven prosthetic heart valves, eight orthopedic prostheses, one artificial urinary sphincter, three contraceptive diaphragms, and three cerebral ventricular shunt tube connectors) not previously evaluated with a high-field-strength MR system, we measured deflection forces at the portal of the magnet of a 1.5-T MR system. Fourteen of the 36 metallic biomedical implants were determined to be ferromagnetic as indicated by their deflection in the static magnetic field. However, only the four aneurysm clips (Drake, Mayfield, McFadden, and Sundt-Kees) had sufficient ferromagnetism to warrant exclusion of patients with these implants from imaging with a 1.5-T MR system because of the possibility of movement or displacement. The calculated deflection forces for these aneurysm clips were comparable with previously reported values of certain aneurysm clips that have been designated to present a risk for patients undergoing MR imaging. Patients with 32 of 36 metallic biomedical implants tested can be safely imaged with high-field-strength MR systems.

Ferric Compounds↗

MR imaging of metallic implants and materials: a compilation of the literature.

Ferromagnetic metallic implants and materials are regarded as contraindications for MR imaging because of the potential risks associated with their movement or displacement. To date, 14 published articles have evaluated the ferromagnetic qualities of 127 different metallic implants and other materials, including aneurysm and hemostatic clips (32); dental implants and materials (five); intravascular coils, filters, and stents (13); ear implants (14); prosthetic heart valves (29); orthopedic implants and materials (eight); penile implants (nine); and miscellaneous metallic implants and materials (17). All of these materials were evaluated by measuring the deflection forces induced by static magnetic fields at strengths ranging from 0.147 to 4.7 T. This article is a compilation of the results of these studies; it lists all 127 of the materials tested, indicates whether they were found to be deflected by the static magnetic fields, and gives the highest static magnetic field strength at which they were evaluated. Of the metallic implants tested, 66 were nonferromagnetic, and 29 exhibited only minimal deflection relative to their in vivo applications (i.e., the deflection forces were thought to be insufficient to move or dislodge the implant or material in situ). The authors of these studies concluded that patients with these particular metallic implants or materials (95/127, 75%) can be examined safely by MR imaging with scanners having static magnetic field strengths up to and including those used for the specific evaluations. Patients with other ferromagnetic materials or implants may also undergo MR imaging safely; however, both careful consideration of the factors that influence the deflection of metallic implants and prudent clinical judgment are required before patients who have these objects are examined via MR imaging.

Magnetic Resonance Imaging↗

Temperature, heart rate, and blood pressure changes associated with clinical MR imaging at 1.5 T.

Temperature, heart rate, and blood pressure responses to high-field-strength magnetic resonance (MR) imaging were studied in 50 patients who underwent procedures at exposures to radiofrequency radiation above the present recommended whole-body average specific absorption rate (SAR) of 0.4 W/kg. Body temperature significantly increased an average of 0.2 degrees C. The highest body temperature recorded after MR imaging was 37.5 degrees C. There was no significant correlation between the change (before and after imaging) in body temperature and whole-body average SARs. Changes in skin temperatures were variable, depending on anatomic site. The largest change was 3.5 degrees C, and the highest skin temperature recorded after imaging was 35.1 degrees C. There was a modest correlation between the change in skin temperatures and whole-body average SARs. Average heart rate and average mean blood pressure measured immediately before imaging were not significantly different afterward. High-field-strength MR imaging at the whole-body average SARs of 0.42-1.2 W/kg studied was not associated with any temperature- or hemodynamic-related deleterious effects.

Blood Pressure↗

Effect of a 1.5 T static magnetic field on body temperature of man.

Reports in the literature concerning the effect of static magnetic fields on the body temperature of mammals have been contradictory and confusing. A significant increase in body temperature in human subjects exposed to the static magnetic fields used in magnetic resonance imaging (MRI) would have important safety implications. Therefore, in two separate studies we determined body temperature in 20 subjects exposed to a 1.5 T static magnetic field. One group of subjects (Group I, N = 9) had sublingual pocket temperature measured immediately before and after a 60 min exposure, while another group of subjects (Group II, N = 11) had esophageal temperature determined at 2 min intervals during a 20 min exposure. No statistically significant changes in body temperature were observed in either Group I or II subjects during exposure to the 1.5 T static magnetic field. We conclude that a relatively intense static magnetic field has no effect on body temperature of normal human subjects.

Adult↗

Brown adipose tissue in cancer patients: possible cause of cancer-induced cachexia.

Cachexia is a common manifestation of advanced cancer and frequently contributes to physical disability and mortality. An increased metabolic rate has been suggested to be one of the causes of cancer-induced cachexia, although the mechanisms producing this hypermetabolism remain unclear. The presence and activation of brown adipose tissue, a highly thermogenic tissue, may result in a hypermetabolic state and be partially responsible for weight loss in cancer patients. To investigate this hypothesis, we examined necropsy samples of peri-adrenal tissues using light microscopy to identify the prevalence of brown adipose tissue in 25 cachectic patients who died from cancer and 15 age-matched subjects who died from other illnesses. Brown adipose tissue was observed in 20 of the cancer patients (80%) compared to 2 of the age-matched subjects (13%). Therefore, our preliminary results indicate that a high prevalence of brown adipose tissue is associated with cancer-induced cachexia and may reflect an abnormal mechanism responsible for profound energy expenditure and weight loss.

Adipose Tissue, Brown↗

Thermoregulatory responses to clinical magnetic resonance imaging of the head at 1.5 tesla. Lack of evidence for direct effects on the hypothalamus.

Warming temperature sensitive neurons in the hypothalamus will induce thermoregulatory heat dissipation. Application of radiofrequency (RF) radiation to the head during magnetic resonance imaging (MRI) could, conceivably, heat the brain, causing a generalized peripheral vasodilation and result in a paradoxical and unnecessary decrease in body temperature. To evaluate the thermoregulatory responses to the RF power deposition used during MRI, we measured body (sublingual pocket) and skin temperatures in 15 patients immediately before and after MRI scans of the head. Ear-skin blood flow was determined by laser-Doppler velocimetry to assess local vasomotor tone. A high-field (1.5 tesla/64 MHz) MRI device (General Electric Company) with a coil designed for head/brain imaging was used in this study. Ambient conditions were room temperature 20-24 degrees C and relative humidity 40-50%. The specific absorption rate averaged over the head ranged from 0.83 to 1.20 W/kg. There was a slight but statistically significant elevation in body temperature (36.5 +/- 0.5 to 36.7 +/- 0.4 degrees C). Skin temperatures of the ear (30.0 +/- 1.2 to 32.0 +/- 0.9 degrees C) and forehead (32.4 +/- 0.5 to 32.8 +/- 0.5 degrees C) increased significantly, while hand (29.9 +/- 1.4 to 29.8 +/- 2.1) skin temperature was unchanged. Ear-skin blood flow also increased a statistically significant amount (average change 36%). The data indicate that there was predominantly surface heating associated with MRI of the head which stimulated a local vasodilating response (i.e. significant increase in ear skin blood flow).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗