Comparative study of permanent interstitial prostate brachytherapy post-implant evaluation among seven Italian institutes.

BACKGROUND AND PURPOSE: The purposes of this multicentric study are (a) the evaluation of four different commercially available treatment planning systems (TPSs) and (b) to verify whether the dosimetric results are comparable, also when considering the inter-observer variabilities and the different scanning protocols used. This work is to be considered a first step to test the value of multicentric studies based on dosimetric evaluation of the quality of the implants. PATIENTS AND METHODS: Four different TPSs were used and the following tests were performed:Comparison of the parameters and mathematical algorithms used; comparison of the dose distributions generated by three different geometries of sources based on 32 dose-points on each source geometry. An octagonal geometric phantom was used to compare volume algorithms and dose-volume histogram (DVH) calculations (V150(Gy), V100(Gy), V50(Gy) and V25(Gy)). Comparison of the post-plan source distribution performed on a prostate-phantom implanted with (125)I seeds. A CT scan of the phantom was obtained at each participating center. Both the geometrical coordinates (with respect to the most caudal one), and the spread of the geometrical distribution, were calculated. The volumes included within different isodoses were also collected. Comparison of the post-plan source distribution performed on an actual patient. Post-plan V100% and D90(Gy) derived from seed distributions obtained by different operators were calculated, using the same target delineation. RESULTS: All the considered TPSs satisfied the AAPM dosimetric parameter recommendations. Point-dose examinations revealed differences smaller than 5%, except for one of the systems. Although the volume algorithm was not the same for all systems, no statistically significant difference was found in the volume measurements. The DVHs also presented differences smaller than 5%, except for one TPS. The distances between the seeds, based on the same CT images, showed a mean SD of 0.13 mm. The mean maximum difference of the position of each seed was 0.36 mm. The most significant errors were made in the cranio-caudal direction (mean maximal difference: 0.44 mm); here the size of the step between slices played an important role. The algorithm of source positioning of the different TPSs may also help explain this difference. The compiled DVHs showed differences smaller than 5%. Post-plans derived from different seed distributions showed a mild dependence upon operators. We obtained a mean value of 97.8 and 152.7 with a percentage of SD of 0.43 and 1.7, respectively, for V100% and D90(Gy). CONCLUSIONS: Three-dimensional (3D) geometric reconstructions of seed distributions are slightly dependent upon the operators and the scanning protocols have little effect on the dosimetric evaluation. Some relevant discrepancies were found between one of the TPSs and the other three if few sources were used; increasing the number of seeds those differences became less pronounced. Multicentric studies on the quality of prostate implants based on post-implant dosimetry are feasible, provided an accurate step-wise evaluation of the procedure be performed.

Aged↗

Performance assessment of coupled tests: the effects of statistical non-independence.

Limited to two-test associations (series and parallel schemes), the effects of statistical non-independence were studied through a mathematical approach and an experimentally-based evaluation. Both procedures were applied to results for total hormones and free fractions in euthyroid and dysthyroid subjects. Assuming independence, the sensitivity of combined tests was found to increase in parallel coupling, and to decrease, symmetrically, in series coupling, depending critically on the degree of between-test correlation and on the value of single test sensitivity (the opposite modifications obviously occur for specificity). A more complicated situation resulted for the predictive value of test associations, where a prediction based on a mathematical model was found not to be generally valid; in this case, calculations using the correct values of conditional probabilities of coupled tests seemingly remain the safest procedure.

Algorithms↗

DECIDE: a software for computer-assisted evaluation of diagnostic test performance.

The evaluation of the performance of clinical tests is a complex problem involving different steps and many statistical tools, not always structured in an organic and rational system. This paper presents a software which provides an organic system of statistical tools helping evaluation of clinical test performance. The program allows (a) the building and the organization of a working database, (b) the selection of the minimal set of tests with the maximum information content, (c) the search of the model best fitting the distribution of the test values, (d) the selection of optimal diagnostic cut-off value of the test for every positive/negative situation, (e) the evaluation of performance of the combinations of correlated and uncorrelated tests. The uncertainty associated with all the variables involved is evaluated. The program works in a MS-DOS environment with EGA or higher performing graphic card.

Clinical Laboratory Techniques↗

The imprecision profile in immunoassay. A study using a resampling technique.

A resampling ('bootstrap') technique was applied to assess the reliability of the calculated imprecision profile (IP), as obtained from the dose/response curve and the response/error relationship (RER) using the cumulative data relative to two assays, i.e. a T4 radioimmunoassay (RIA) and a TSH immunofluorometric assay (IFMA), both run in duplicate. Mean values and the related uncertainty of the estimated dose errors were compared for different RER fitting conditions and different sizes of the duplicate response sets. The following observations were made: (a) compared to the maximum-likelihood procedure, the least-square fit proved to be unsuitable for estimating the parameters in the general RER equation variance(R) = aRb (where R indicates the response), (b) the simplifying assumption of a within-method constancy of the exponent in the RER equation, while acceptable for the T4 RIA, did not hold in the case of the TSH IFMA implying a much wider response range, (c) for both assays, response sets of ca. 100 duplicates were apparently compatible with an acceptable definition of the IP (+/- 10 to +/- 20% uncertainty).

Bias↗