PubMed Health⌕ Search

Biomedical subjects

F Godley

Publications and source records attributed to F Godley.

5 recordsLinked to original sources

Effect of uvulopalatopharyngoplasty on upper airway collapsibility in obstructive sleep apnea.

Previous investigators have demonstrated variable responses to uvulopalatopharyngoplasty (UPP) in patients with obstructive sleep apnea. We hypothesized that this variability is due to either (1) differences in baseline pharyngeal collapsibility preoperatively or (2) differences in magnitude of the decrease in pharyngeal collapsibility resulting from surgery. To determine the relationship between changes in collapsibility and the response to UPP surgery, we measured the upper airway critical pressure (Pcrit) before and after UPP in 13 patients with obstructive sleep apnea. During non-REM sleep, maximal inspiratory airflow (VImax) was quantitated by varying the level of nasal pressure (PN), and Pcrit was determined by the level of PN below which VImax ceased. A positive response to UPP was defined by a greater than or equal to 50% fall in non-REM disordered breathing rate (DBR). In the entire group, UPP resulted in significant decreases in DBR from 71.1 +/- 22.4 to 44.7 +/- 38.4 episodes/h (p = 0.025) and in Pcrit from 0.2 +/- 2.4 to -3.1 +/- 5.4 cm H2O (p = 0.016). Moreover, the percent change in DBR was correlated significantly with the change in Pcrit (p = 0.001). Subgroup analysis of responders and nonresponders demonstrated that significant differences in Pcrit were confined to the responders. Specifically, responders demonstrated a significant fall in Pcrit from -0.8 +/- 3.0 to -7.3 +/- 4.9 cm H2O (p = 0.01), whereas no significant change in Pcrit was detected in the nonresponders (1.1 +/- 1.6 versus 0.6 +/- 2.0 cm H2O. No clinical, polysomnographic, or physiologic predictors of a favorable response were found preoperatively.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Imaging of acute arterial injury with 111In-labeled platelets: a comparison with scanning electron micrographs.

The relationship between degree of acute arterial injury, extent of platelet deposition, and ability to visualize arterial injury with Indium 111-labeled platelets was studied in 18 rabbits. An aortic lesion was made with a balloon catheter in each animal immediately after injection of autologously labeled platelets. Three nonlesioned rabbits with 111In-labeled platelets served as controls. An additional control study was performed in 12 lesioned rabbits in which nine were injected with 111In-labeled plasma protein and three with 111In-labeled red blood cells. A postmortem scanning electron microscope study of the aortae was made to determine the degree of injury to the intima and the amount of platelet deposition on the damaged arterial wall. The radionuclide scans and scanning electron micrographs were then compared. Lesions were seen in ten of 18 animals with labeled platelets that had extensive regions of denuded endothelium covered by a contiguous layer of platelets. Lesions consisting of patchy deendothelialization and platelet deposition could not be visualized on the scans. Red blood cells and fibrin were not conspicuous on micrographs of the lesions. No lesions were visualized in animals receiving 111In-labeled plasma protein or red blood cells before arterial injury, despite platelet deposition in the lesions.

Animals↗

Selection of video cameras for stroboscopic videolaryngoscopy.

Stroboscopic evaluation for the analysis of laryngeal function and disease has been reemphasized recently and its routine clinical use recommended. Many have found, however, that it is not always possible to obtain consistently satisfactory video images of stroboscopic laryngoscopy. The problem is related to the low intensity of the xenon light source during stroboscopy. The authors have tried many different video cameras available, along with the Brüel & Kjaer Rhino-Larynx Stroboscope type 4914, and two types of endoscopes (flexible and rigid). The cameras included 1) single tube camera, 2) single chip metal oxide semiconductors (MOS) solid-state camera, 3) single chip charge-coupled devices (CCD) solid-state camera, 4) three-tube camera, and 5) three-chip CCD camera. Currently available video cameras and their adaptability for stroboscopic videolaryngoscopy are discussed.

Equipment Design↗