PubMed Health⌕ Search

Biomedical subjects

F H Chan

Publications and source records attributed to F H Chan.

26 records · Page 2Linked to original sources

Spectral characteristics of embolic heart sounds detected by precordial Doppler ultrasound during venous air embolism in dogs.

We have studied the frequency spectrum of embolic heart sounds as detected by precordial Doppler ultrasound after injecting air 0.01-0.1 ml into the external jugular vein of anaesthetized dogs (n = 7). At volumes of 0.05 ml and greater, there was a significant increase in both the maximum frequency of the spectrum and the power of those high frequency components to greater than control values. Both changes correlated significantly with the volume of air injected (P < 0.05). With repeated injections of air at 5-min intervals, there was a small increase in the high frequency components in the control signal between injections (P < 0.05). We conclude that such spectral changes could be used to quantify the volume of air in transit through the heart, and to reflect the short-term history of venous air embolism.

Animals↗

Measurement of human BAERs by the maximum length sequence technique.

The traditional brainstem auditory evoked response (BAER) measurement technique (ensemble averaging) is time-consuming and is not acceptable for some time-critical clinical applications. In the paper the application of a pseudorandom binary sequence, the maximum length sequence, to human BAER measurements is examined. This technique permits a faster click rate to stimulate the test subject, and obtains a higher signal-to-noise ratio (SNR) response through deconvolution. When compared with conventional averaging, the method can result in an improved SNR or in faster measurement of BAER. The theory of the technique and the experimental setup are presented, and theoretical analysis on the SNR improvement by this technique against averaging is also given. Actual measurements of BAER on both humans and cats indicate that this technique is effective, especially when the measurement time is not too long, or the number of trials is not too large.

Algorithms↗

Visual evoked potential measurement by maximum length sequence technique.

The maximum length sequence (MLS) technique is applied to improve data collection of a clinically important long latency visual potential. Given a limited time for measuring the response and with low number of stimulus presentation, the MLS technique exceeded the conventional method of ensemble averaging in attaining a higher signal-to-noise ratio (SNR). The theoretical consideration of such improvement is developed along with the system implementation. Typical examples of the results obtained in a human subject are presented.

Algorithms↗

Maximum length sequence applied to the measurement of brainstem auditory evoked responses.

An evoked response may be assumed to consist of synchronous electrical activities of groups of neurons in response to a stimulus. Unfortunately, this response is usually weak and often masked by the background EEG activity generated spontaneously by the brain. In order to extract the embedded evoked response we have employed the theory of maximum length sequence, assuming only a temporal linearity of the system from which measurements are taken. The technique has been applied successfully with the aid of a microcomputer. The system also supports the same measurement by a conventional averaging technique. The results of the two are compared, indicating the advantages of the maximum length technique: improved signal-to-noise ratio, repeatability and speed.

Animals↗

A microcomputer-based binaural measurement system.

A microcomputer is used to control a dual-channel, sine-wave generator as the excitation to both the left and right ears in experimental subjects, and for on-line measurement of the neuronal spike counts. The effects of varying the walking pattern and phase angle between the two channels can be investigated. After normalisation of spike counts, the result can be displayed as a 3-D plot on a CRT or an x-y plotter. The system is useful for general steady state and transient binaural measurement.

Biomedical Engineering↗

The changing perinatal and maternal outcome in chorioamnionitis.

Chorioamnionitis is difficult to detect clinically, but its recognition in those at risk is essential. A retrospective study of 140 patients from among 26,129 deliveries was conducted over a 2-year period. The findings suggest that in modern obstetric practice, both perinatal and maternal complications associated with chorioamnionitis (particularly sepsis) are infrequent problems. Four neonatal deaths occurred but no infants died of sepsis. There were no maternal deaths, but 38 patients developed postpartum infections. Cesarean section did not appear to improve either perinatal or maternal outcome. With the use of appropriate modern antibiotics, extraperitoneal cesarean section and cesarean hysterectomy are probably no longer indicated. Not all neonates born out of a microbiologically contaminated intrauterine environment required antibiotic therapy, however, and individualization is recommended.

Amnion↗

An ultrasonogram display system using a natural color scale.

The gray scale display used in B scan ultrasonography limits the perceptibility of clinically useful information. Presentation in color can increase perceptibility, but current color displays have no natural scale and may have the fault of a discrete color spectrum. The continuous heated-object color spectrum solves these problems. To produce a display using this spectrum, we have built an inexpensive system to adapt the scan converter output of a gray scale ultrasonograph to a commercial color television.

Adult↗

Microcomputer-based spike train analysis.

A system has been developed to analyse statistically the information contained within neuronal spike trains in the central nervous system. The system consists of a microprocessor development system, together with the peripheral components and transducers. Suitable software packages have been developed to analyse statistical parameters including the mean, variance, entropy, conditional entropy, serial correlation coefficients, Markov dependency and Markov order. By linking up the required routines, the system is capable of responding in real-time and plotting the desired results from the spike train obtained. Such system has been used to study the neuronal spike trains recorded from central vestibular neurons which could be affected by positional changes, anaesthetics and various drugs for the relief of motion sickness.

Animals↗