PubMed Health⌕ Search

Biomedical subjects

F H Y Chan

Publications and source records attributed to F H Y Chan.

3 recordsLinked to original sources

Automatic correction of artifact from single-trial event-related potentials by blind source separation using second order statistics only.

Event-related potentials (ERP) are in general masked by various kinds of artifacts. To attenuate the effects of artifacts, various schemes have been introduced, such as epoch rejection, electro-oculogram (EOG) regression and independent component analysis (ICA). However, none of the existing techniques can automatically remove various kinds of artifacts from a single ERP epoch. EOG regression cannot handle artifacts other than ocular ones. ICA incorporating higher order statistics (HOS) normally requires data with large number of time samples in order that the solution is robust. In this paper we blindly separate the multi-channel ERP into source components by estimating the correlation matrices of the data. Since only second order statistics (SOS) is involved, the process performs well at the single epoch level. Automatic artifact identification is performed in the source domain by introducing objective criteria for various artifacts. Criteria are based on time domain signal amplitude for blink and spurious peak artifact, scalp distribution of signal power for eye movement artifact and power distribution of frequency components for muscle artifact. The correction procedure can be completed by removing the identified artifactual sources from the raw multi-channel ERP.

Algorithms↗

Free radical EPR spectroscopy analysis using blind source separation.

In this paper, we propose a novel approach for electron paramagnetic resonance (EPR) mixture spectra analysis based on blind source separation (BSS) technique. EPR spectrum of a free radical is often superimposed by overlapping spectra of other species. It is important and challenging to accurately identify and quantify the 'pure' spectra from such mixtures. In this study, an automated BSS method implementing independent component analysis is used to extract the components from mixed EPR spectra that contain overlapping components of different paramagnetic centers. To apply this method, there is no requirement to know the component spectra or the number of components in advance. The method is applied to analyze free radical EPR spectra which are collected from standard chemical system, cultured cell suspense, and ex vivo rat kidneys by spin trapping EPR technique. Results show that the BSS method proposed here is capable of identifying the component EPR spectra from mixtures with unknown compositions. The BSS technique can offer powerful aids in resolving spectral overlapping problems in general EPR spectroscopy analysis.

Algorithms↗

In vitro calibration and validation of a digital subtraction radiography system using scanned images.

OBJECTIVES: To calibrate and validate a digital subtraction radiography system using scanned images for quantification of alveolar bone changes by means of computer-assisted densitometric image analysis (CADIA) in vitro. MATERIALS AND METHODS: Noise levels were determined using 10 standardized periapical radiographs of the same lower molar region in a human dry skull. For validation of the system, radiographs were taken before and after bovine bone particles in measures with increments of 2 mg weighing from 2 to 20 mg were added into each socket of three dry skulls. Radiographs were developed and scanned into a computer with a flatbed scanner. After digitization, the images were subjected to alignment, normalization and subtraction. Appropriate regions of interest (ROIs) were selected and their CADIA values were calculated for the determination of noise levels, and correlations between the CADIA values and the actual bone mass were performed. RESULTS: When the threshold value was 7, the percentage of pixels deviating from the set threshold value was small (0-11.3%). There were statistically significant correlations between the actual bone mass and the CADIA value for anterior sockets (p<0.001, r2=0.89) and posterior sockets (p<0.001, r2=0.9). For pooled data of both anterior and posterior sockets, the correlation was also statistically significant (p<0.001, r2=0.88). CONCLUSIONS: A high and statistically significant correlation between the actual bone mass and CADIA value was obtained, which suggests that the system could be suitable for the detection of small alveolar bone changes.

Absorptiometry, Photon↗