PubMed Health⌕ Search

Biomedical subjects

F J Beekman

Publications and source records attributed to F J Beekman.

21 records · Page 2Linked to original sources

SPECT scatter modelling in non-uniform attenuating objects.

SPECT quantitation and image contrast are degraded by photon scatter. Water equivalent depths (WEDs) have been used by several investigators to model scatter responses in non-uniform attenuators. The drawback of this approach is the occurrence of undesired fluctuations in the shape of the scatter responses, as is shown by measurements. An improvement of the WED method is presented, based on the assumption that only a part of the scattering object (the region in the 'scatter cone') contributes significantly to the detected scatter events. The remaining part of the object is treated as a uniform medium. The extension of the WED method with extra-conical invariance (WEDECI) is evaluated by projection measurements of a phantom with a 99mTc source. Shapes of scatter responses predicted by the WEDECI method are found to agree better with the measurements than those predicted by conventional WEDs.

Algorithms↗

Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study.

Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during iterative reconstruction ('ideal scatter model', ISM); (iv) no scatter compensation (NSC); (v) ideal scatter rejection (ISR), as can be approximated by using a camera with a perfect energy resolution. The iterative method used was an ordered subset expectation maximization (OS-EM) algorithm. A cylinder containing small cold spheres was used to calculate contrast-to-noise curves. For a brain study, global errors between reconstruction and 'true' distributions were calculated. Results show that ISR is superior to all other methods. In all cases considered, ISM is superior to ISE and performs approximately as well as (brain study) or better than (cylinder data) ISE-NF. Both ISM and ISE improve contrast-to-noise curves and reduce global errors, compared with NSC. In the case of ISE, blurring of the scatter estimate with a Gaussian kernel results in slightly reduced errors in brain studies, especially at low count levels. The optimal Gaussian kernel size is strongly dependent on the noise level.

Algorithms↗

Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography.

Clinical Single Photon Emission Computed Tomography (SPECT) is a scanning technique which acquires gamma-camera images ('projections') over a range of angles around a patient. These projections allow the reconstruction of cross sectional ('tomographic') images of the gamma-radiating pharmaceutical distribution in the patient, thus providing interesting information about the functioning of organs and tissues.SPECT images are seriously affected by a variety of image degrading processes. Restrictions on the amount of radio-pharmaceutical that can be administered to a patient cause noise in the projections and the limited spatial resolution of the gamma-camera results in blurring of the projections. In addition to these image degradations, the reconstruction of cross-sections is complicated by Compton scattering of gamma-photons in tissue, which causes attenuation of the photon flux received by the gamma-camera and causes improper detection of photons which have been scattered in tissue. This results in some additional blurring and loss of accuracy of the SPECT images in predicting activity concentrations. Tremendous efforts have been made to improve the quantitative accuracy and the spatial resolution of SPECT, and to reduce the noise in the reconstructed images. These efforts have resulted in corrective reconstruction algorithms, which are generally based on incorporation of accurate models of the main image degrading factors. Improvements of the data acquisition hardware can further increase image quality. In this paper, the image formation process of SPECT, including image-degrading factors, is explained. In addition, reconstruction algorithms and hardware modifications are reviewed, and their effects on image quality are illustrated with physical phantom and simulation experiments.

Algorithms↗