PubMed Health⌕ Search

Biomedical subjects

F J Bova

Publications and source records attributed to F J Bova.

At least 37 records · Page 2Linked to original sources

Linac radiosurgery for benign meningiomas.

PURPOSE: To review outcomes for patients treated with linac radiosurgery for benign meningiomas. METHODS AND MATERIALS: Between January 1989 and July 1997, 70 patients with 76 meningiomas were treated with LINAC-based radiosurgery. In 38 patients, radiosurgery was the initial treatment. In 32 patients, radiosurgery followed surgery or conventional radiotherapy. The average treatment volume was 10.0 cm3 (range, 0.6 to 28.6 cm3). The mean peripheral dose was 12.7 Gy (range, 10 to 20 Gy). The mean clinical follow-up period was 23 months. No patient was lost to follow-up. RESULTS: No lesions enlarged during the follow-up period; of 48 lesions in patients who had follow-up for at least one year and hence had follow-up imaging, 27 tumors remained unchanged and 21 tumors were reduced in size. Two patients experienced transient radiation-induced neurological deficits. One was treated with surgical excision of the tumor; the other responded to prolonged steroid therapy. Both patients, treated early in our experience, received doses higher than we would currently recommend. CONCLUSIONS: Early results suggest that stereotactic radiosurgery is an effective treatment for meningiomas. Long-term follow-up will be necessary to fully evaluate its efficacy.

Adult↗

The midline dose distribution for a three-field radiotherapy technique.

At the University of Florida, head and neck cancer often is irradiated using parallel opposed lateral fields (with inferior borders slanted superiorly) and an anterior low neck field. A common criticism is that overlap may occur at the match-line junction of the three fields, resulting in an increased risk of radiation myelitis. One setup for treatment of the oropharynx and two for the larynx were irradiated in an anthropomorphic head and neck phantom made of tissue-equivalent polyacrylamide gel with a two-dimensional thermoluminescent dosimeter array in its sagittal midplane. The results showed that no excess radiation dose was measured at the junction of the three fields. The "spinal cord dose," as percentage of dose to the central axis of the primary field, was as follows: oropharynx setup, 15% to 100%; larynx setup with midline tracheal block, 10% to 90%; larynx setup without tracheal block, 10% to 90%. In conclusion, the University of Florida three-field technique for head and neck cancer produces no measured increase in dose at field junctions.

Acrylic Resins↗

Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization.

Linear accelerator (linac) radiosurgery utilizes non-coplanar arc therapy delivered through circular collimators. Generally, spherically symmetric arc sets are used, resulting in nominally spherical dose distributions. Various treatment planning parameters may be manipulated to provide dose conformation to irregular lesions. Iterative manipulation of these variables can be a difficult and time-consuming task, because (a) understanding the effect of these parameters is complicated and (b) three-dimensional (3D) dose calculations are computationally expensive. This manipulation can be simplified, however, because the prescription isodose surface for all single isocentre distributions can be approximated by conic sections. In this study, the effects of treatment planning parameter manipulation on the dimensions of the treatment isodose surface were determined empirically. These dimensions were then fitted to analytic functions, assuming that the dose distributions were characterized as conic sections. These analytic functions allowed real-time approximation of the 3D isodose surface. Iterative plan optimization, either manual or automated, is achieved more efficiently using this real time approximation of the dose matrix. Subsequent to iterative plan optimization, the analytic function is related back to the appropriate plan parameters, and the dose distribution is determined using conventional dosimetry calculations. This provides a pseudo-inverse approach to radiosurgery optimization, based solely on geometric considerations.

Humans↗

Dosimetric characteristics of a double-focused miniature multileaf collimator.

The dosimetric characteristics of a double-focused miniature multileaf collimator (mMLC) attached to a Philips SL75/5 linear accelerator (linac) have been investigated. Output factors, percentage depth-dose, penumbra, leaf transmission, and leakage between the leaves were measured for the 6 MV x-ray beam on this accelerator. Because leakage both through and between the leaves is minimal, the linac jaws can be kept fixed while the mMLC leaf configuration is modified for different aperture shapes. This allows for accurate output prediction using the equivalent square formalism. Percent depth-dose measured for fields defined by the mMLC show little deviation from the percent depth-dose measured for fields defined by the machine jaws or Lipowitz metal blocks. Because the mMLC matches beam divergence in both directions, allows minimal beam transmission, and has a large source-to-collimator distance, the penumbra is sharper for fields defined by the mMLC than for fields defined by the linac jaws or Lipowitz metal blocks. Based on these data, dose calculations for mMLC-defined fields can be applied with no change in procedures from those used for fields defined using conventional methods.

Radiotherapy Planning, Computer-Assisted↗

Linear accelerator radiosurgery in brain tumor management.

This article begins with a brief introduction to the concepts and techniques of linear accelerator-based stereotactic radiosurgery. The expanding role of radiosurgery in the treatment of brain tumors is explored in depth, including detailed discussions of the five intracranial neoplasms most frequently treated with radiosurgery. These include both benign (i.e., vestibular schwannoma, meningioma, pituitary adenoma) and malignant (i.e., cerebral metastasis, malignant glioma) pathologies. For each of these, a thorough review of published radiosurgical results is presented along with a discussion of common treatment modalities. The role of radiosurgery in the treatment of brain tumors continues to be defined, but an effort is made to provide reasonable indications for and against radiosurgery based on the current state of the art.

Adenoma↗

Feline bone marrow transplantation: its use in FIV-infected cats.

The use of autologous and allogenic bone marrow transplantations (BMT) in FIV-infected and uninfected cats is a novel therapy for feline hematopoietic diseases and retroviral infections. A total of 13 specific pathogen-free (SPF) cats received either autologous or allogenic BMT and seven of these cats were also infected with FIV before autologous or allogenic BMT. All BMT recipients received total body irradiation of 900 cGy just before BMT. Two FIV-infected and four uninfected cats received autologous uninfected BM cells cryopreserved before BMT. Five infected and two uninfected cats received BM cells from allogenic uninfected donors (RBC-, MHC-, and cross-matched). MHC-matching was based on mixed leucocyte reaction (MLR) and the donor-recipient combination which was compatible by MLR analysis, was used in this study. Recipients were monitored for hematology, immunology, virology, and clinical signs. All FIV-infected and uninfected recipients of autologous BMT had complete engraftment with minimal complications. Uninfected recipients of allogenic BMT had a more severe clinical episode with slower rate of engraftment. None of these BMT groups had mortality. In contrast, only two of the five infected recipients of allogenic BMT survived for a significant period of time (23 and 50 weeks) and rest of the cats succumbed to transfusion reactions. Both infected BMT groups had persistent CD4/CD8 inversion, low CD4+ cell counts, and FIV infection of engrafted peripheral blood mononuclear cells (PBMC). Overall, successful autologous and allogenic BMTs were performed in FIV-free cats. All infected recipients of autologous BMT had compete engraftment and are currently alive, with thelongest survival time being over 1 year. Thus, BMT in combination with antiviral drug therapies may be an alternative therapy against retroviral infection.

Animals↗

Preliminary experience with frameless stereotactic radiotherapy.

PURPOSE: To report initial clinical experience with a novel high-precision stereotactic radiotherapy system. METHODS AND MATERIALS: Sixty patients ranging in age from 2 to 82 years received a total of 1426 treatments with the University of Florida frameless stereotactic radiotherapy system. Of the total, 39 (65%) were treated with stereotactic radiotherapy (SRT) alone, and 21 (35%) received SRT as a component of radiotherapy. Pathologic diagnoses included meningiomas (15 patients), low-grade astrocytomas (11 patients), germinomas (9 patients), and craniopharyngiomas (5 patients). The technique was used as means of dose escalation in 11 patients (18%) with aggressive tumors. Treatment reproducibility was measured by comparing bite plate positioning registered by infrared light-emitting diodes (IRLEDs) with the stereotactic radiosurgery reference system, and with measurements from each treatment arc for the 1426 daily treatments (5808 positions). We chose 0.3 mm vector translation error and 0.3 degrees rotation about each axis as the maximum tolerated misalignment before treating each arc. RESULTS: With a mean follow-up of 11 months, 3 patients had recurrence of malignant disease. Acute side effects were minimal. Of 11 patients with low grade astrocytomas, 4 (36%) had cerebral edema and increased enhancement on MR scans in the first year, and 2 required steroids. All had resolution and marked tumor involution on follow-up imaging. Bite plate reproducibility was as follows. Translational errors: anterior-posterior, 0.01 +/- 0.10; lateral, 0.02 +/- 0.07; axial, 0.01 +/- 0.10. Rotational errors (degrees): anterior-posterior, 0.00 +/- 0.03; lateral, 0.00 +/- 0.06; axial, 0.01 +/- 0.04. No patient treatment was delivered beyond the maximum tolerated misalignment. Daily treatment was delivered in approximately 15 min per patient. CONCLUSION: Our initial experience with stereotactic radiotherapy using the infrared camera guidance system was good. Patient selection and treatment strategies are evolving rapidly. Treatment accuracy was the best reported, and the treatment approach was practical.

Adolescent↗

IRLED-based patient localization for linac radiosurgery.

PURPOSE: Currently, precise stereotactic radiosurgery delivery is possible with the Gamma Knife or floor-stand linear accelerator (linac) systems. Couch-mounted linac radiosurgery systems, while less expensive and more flexible than other radiosurgery delivery systems, have not demonstrated a comparable level of precision. This article reports on the development and testing of an optically guided positioning system designed to improve the precision of patient localization in couch-mounted linac radiosurgery systems. METHODS AND MATERIALS: The optically guided positioning system relies on detection of infrared light-emitting diodes (IRLEDs) attached to a standard target positioner. The IRLEDs are monitored by a commercially available camera system that is interfaced to a personal computer. An IRLED reference is established at the center of stereotactic space, and the computer reports the current position of the IRLEDs relative to this reference position. Using this readout from the computer, the correct stereotactic coordinate can be set directly. RESULTS: Bench testing was performed to compare the accuracy of the optically guided system with that of a floor-stand system, that can be considered an absolute reference. This testing showed that coordinate localization using the IRLED system to track translations agreed with the absolute to within 0.1 +/- 0.1 mm. As rotations for noncoplanar couch angles were included, the inaccuracy was increased to 0.2 +/- 0.1 mm. CONCLUSIONS: IRLED technology improves the accuracy of patient localization relative to the linac isocenter in comparison with conventional couch-mounted systems. Further, the patient's position can be monitored in real time as the couch is rotated for all treatment angles. Thus, any errors introduced by couch inaccuracies can be detected and corrected.

Humans↗

Treatment planning optimization for linear accelerator radiosurgery.

PURPOSE: Linear accelerator radiosurgery uses multiple arcs delivered through circular collimators to produce a nominally spherical dose distribution. Production of dose distributions that conform to irregular lesions or conformally avoid critical neural structures requires a detailed understanding of the available treatment planning parameters. METHODS AND MATERIALS: Treatment planning parameters that may be manipulated within a single isocenter to provide conformal avoidance and dose conformation to ellipsoidal lesions include differential arc weighting and gantry start/stop angles. More irregular lesions require the use of multiple isocenters. Iterative manipulation of treatment planning variables can be difficult and computationally expensive, especially if the effects of these manipulations are not well defined. Effects of treatment parameter manipulation are explained and illustrated. This is followed by description of the University of Florida Stereotactic Radiosurgery Treatment Planning Algorithm. This algorithm organizes the manipulations into a practical approach for radiosurgery treatment planning. RESULTS: Iterative treatment planning parameters may be efficiently manipulated to achieve optimal treatment plans by following the University of Florida Treatment Planning Algorithm. The ability to produce conformal stereotactic treatment plans using the algorithm is demonstrated for a variety of clinical presentations. CONCLUSION: The standard dose distribution produced in linear accelerator radiosurgery is spherical, but manipulation of available treatment planning parameters may result in optimal dose conformation. The University of Florida Treatment Planning Algorithm organizes available treatment parameters to efficiently produce conformal radiosurgery treatment plans.

Algorithms↗

Potential clinical efficacy of intensity-modulated conformal therapy.

PURPOSE: The purpose of this study was to examine the potential benefit of using intensity-modulated conformal therapy for a variety of lesions currently treated with stereotactic radiosurgery or conventional radiotherapy. METHODS AND MATERIALS: Intensity-modulated conformal treatment plans were generated for small intracranial lesions, as well as head and neck, lung, breast, and prostate cases, using the Peacock Plan treatment-planning system (Nomos Corporation). For small intracranial lesions, intensity-modulated conformal treatment plans were compared with stereotactic radiosurgery treatment plans generated for patient treatment at the University of Florida Shands Cancer Center. For other sites (head and neck, lung, breast, and prostate), plans generated using the Peacock Plan were compared with conventional treatment plans, as well as beam's-eye-view conformal treatment plans. Plan comparisons were accomplished through conventional qualitative review of two-dimensional (2D) dose distributions in conjunction with quantitative techniques, such as dose-volume histograms, dosimetric statistics, normal tissue complication probabilities, tumor control probabilities, and objective numerical scoring. RESULTS: For small intracranial lesions, there is little difference between intensity-modulated conformal treatment planning and radiosurgery treatment planning in the conformation of high isodose lines with the target volume. However, stereotactic treatment planning provides a steeper dose gradient outside the target volume and, hence, a lower normal tissue toxicity index. For extracranial sites, objective numerical scores for beam's-eye-view and intensity-modulated conformal planning techniques are superior to scores for conventional treatment plans. The beam's-eye-view planning technique prevents geographic target misses and better excludes healthy tissues from the treatment portal. Compared with scores for the beam's-eye-view planning technique, scores for intensity-modulated conformal plans using the Peacock Plan were significantly better for the lung and head and neck cases studied, equivalent for prostate cases, and inferior for breast cases. CONCLUSION: Using the entire 3D data set to construct radiotherapy plans through virtual simulation is always advantageous, whether done for stereotactic radiosurgery, beam's-eye-view conformal therapy, or intensity-modulated conformal treatment. Intensity modulation of the photon beam further enhances treatment planning under specific conditions. In general, the intensity-modulated technique is advantageous for large, irregular targets with critical structures in close proximity. Intensity-modulated treatment planning does not appear advantageous for stereotactic radiosurgery or treatment of the intact breast.

Aged↗

The radiobiology of radiosurgery and stereotactic radiotherapy.

Radiation therapy has evolved into a complex amalgamation of treatment techniques that differ significantly according to the way the radiation is delivered to the patient and coincidentally according to the biologic effects that are observed with each technique. Although there are concepts within radiobiology that unify the field, it is not apparent that the biologic effects with one methodology of treatment resemble those of another. Radiosurgery, although initially developed in the 1950s, has become more commonly used in recent years. This treatment involves high-dose, single-fraction treatments with sharp dose gradients to small volumes of tissue. This contrasts with conventional external-beam radiotherapy which involves small-dose, multiple-fraction, broad-dose-gradient treatment to relatively large volumes of tissue. Stereotactic radiotherapy generally delivers small-dose, multiple-fraction treatments to small or intermediate volumes of tissue with a sharp dose gradient compared with conventional external-beam treatment. A discussion of these technique differences with reference to the radiobiologic implications may help elucidate the potential utility of the techniques in clinical radiotherapy.

Brain Neoplasms↗

Linac scalpel radiosurgery at the University of Florida.

Optimal implementation of stereotactic radiosurgery requires multidisciplinary input from neurosurgeons, radiation oncologists, and physicists. Clinical processes of most importance to the physics staff include stereotactic imaging, treatment planning, and radiation delivery. Careful attention to each of these details helps to ensure the quality of the overall process. Here we provide a practical review of the clinical processes involved in linac scalpel radiosurgery. The linac scalpel system is a linear-accelerator-based radiosurgery system that was developed at the University of Florida. It has been used at the University of Florida to treat more than 1000 patients since 1988. The aim of the linac scalpel system is to minimize all possible uncertainties in imaging and treatment delivery. Once these errors are minimized, truly conformal treatment plans can be generated and delivered with confidence, allowing clinicians to focus solely on the patient's problem. By following practical examples of this well established system, many pitfalls in the clinical process can be avoided.

Cerebral Angiography↗

Optic-guided stereotactic radiotherapy.

Stereotactic localization provides a powerful referencing system for radiation planning and treatment delivery. Although the standard approach of applying a rigid reference frame has been accepted for single-fraction therapy, a new, noninvasive approach is needed for fractionated therapy. The use of optical tracking allows a patient's position to be monitored in real time with a truly touch-free system. Our optical system provides high precision and accuracy for repeat fixation and can be applied to a wide spectrum of patients. With this system, a stereotactic radiation treatment can be delivered in the same length of time as a routine fractionated radiation treatment.

Brain Neoplasms↗

Analysis of treatment failure after radiosurgery for arteriovenous malformations.

OBJECT: The aim of this study was to evaluate the causes of treatment failure in patients with arteriovenous malformations (AVMs) who underwent radiosurgery, which is increasingly used as a treatment method for selected, surgically high-risk AVMs. Unfortunately, radiosurgical treatment fails in a small but significant percentage of patients. In the time period covered in this study, 72 patients attained angiographically confirmed cures after radiosurgery and 36 were retreated after the initial radiosurgical treatment failed. METHODS: Using a computerized image fusion technique, the initial radiosurgical dosimetry plan was superimposed on the remaining AVM nidus at the time of retreatment. Twenty-six percent of the retreated cases were found to have AVM niduses outside the original treatment isodose line, which means that targeting error was a factor. The retreated group was also statistically compared with the cured group. CONCLUSIONS: Multivariate analysis revealed that the following factors were statistically significant predictors of treatment failure: increasing AVM size, decreasing treatment dose, and increasing Spetzler-Martin grade.

Cerebral Angiography↗

Fractionation of feline bone marrow with the soybean agglutinin lectin yields populations enriched for erythroid and myeloid elements: transplantation of soybean agglutinin-negative cells into lethally irradiated recipients.

Feline bone marrow cells treated with the soybean agglutinin (SBA) lectin are separated into two populations, the agglutinated SBA(+) fraction containing predominantly cells of myeloid origin and the nonagglutinated SBA(-) fraction consisting of cells primarily of the erythroid lineage. FACScan analyses revealed a clear distinction of the cells based on their light scattering properties, i.e., large cells and cells with high granularity were found in the SBA(+) fraction, whereas cells having a low forward light scatter and side light scatter were found in the SBA(-) fraction. Colony-forming assays showed colony-forming unit-granulocyte/monocyte (CFU-GM) cells to have a strong affinity for SBA because these were found almost entirely in the SBA(+) fraction; in contrast, burst-forming unit-erythroid (BFU-E)-forming cells were concentrated in the SBA(-) fraction. When the marrow was fractionated by counterflow centrifugal elutriation (CCE), a differential binding to SBA among the CFU-GM forming cells was found. The SBA(-) fractions of cells collected at 21 and 25 ml/min contained primarily BFU-E forming cells, similar to that observed with whole marrow; the later CCE fractions, those collected at 32 ml/min and the rotor off fraction, when treated with SBA showed a small but significant number of CFU-GM cells in the SBA(-) fraction. T lymphocytes were found predominantly in the SBA(+) fractions of whole bone marrow and the CCE fractions. Successful autologous marrow transplants were performed with the early CCE SBA(-) fractions. The latter cells were used for our initial transplant attempts because ongoing studies in our laboratory had shown these cells to be free of any viral-containing cells when the marrow had been obtained from animals infected with the feline immunodeficiency virus. In summary, although SBA treatment of feline marrow yields a marked separation of CFU-GM and BFU-E progenitors, select CCE SBA(-) fractions contain stem cells capable of providing hematopoietic reconstitution of lethally irradiated animals.

Animals↗

The University of Florida frameless high-precision stereotactic radiotherapy system.

PURPOSE: To develop and test a system for high precision fractionated stereotactic radiotherapy that separates immobilization and localization devices. METHODS AND MATERIALS: Patient localization is achieved through detection and digital registration of an independent bite plate system. The bite plate is made and linked to a set of six infrared light emitting diodes (IRLEDs). These IRLEDs are detected by an infrared camera system that identifies the position of each IRLED within 0.1 to 0.15 mm. Calibration of the camera system defines isocenter and translational X, Y, and Z axes of the stereotactic radiosurgery subsystem and thereby digitally defines the virtual treatment room space in a computer linked to the camera system. Positions of the bite plate's IRLEDs are processed digitally using a computer algorithm so that positional differences between an actual bite plate position and a desired position can be resolved within 0.1 mm of translation (X, Y, and Z distance) and 0.1 degree of rotation. Furthermore, bite plate misalignment can be displayed digitally in real time with translational (x, y, and z) and rotational (roll, pitch, and yaw) parameters for an actual bite plate position. Immobilization is achieved by a custom head mold and thermal plastic mask linked by hook-and-loop fastener tape. The head holder system permits rotational and translational movements for daily treatment positioning based on the bite plate localization system. Initial testing of the localization system was performed on 20 patients treated with radiosurgery. The system was used to treat 11 patients with fractionated stereotactic radiotherapy. RESULTS: Assessment of bite plate localization in radiosurgery patients revealed that the patient's bite plate could be positioned and repositioned within 0.5 +/- 0.3 mm (standard deviation). After adjustments, the first 11 patients were treated with the bite plate repositioning error reduced to 0.2 +/- 0.1 mm. CONCLUSIONS: High precision stereotactic radiotherapy can be delivered using separate localization and immobilization systems. Treatment setup and delivery can be accomplished in 15 min or less. Advantages compared with standard systems require further study.

Adult↗

Accelerated hyperfractionated radiotherapy for malignant gliomas.

PURPOSE: To evaluate accelerated hyperfractionated radiotherapy for the treatment of malignant gliomas. METHODS AND MATERIALS: Between April 1985 and June 1994, 70 adult patients with pathologically confirmed malignant glioma (75% glioblastoma multiforme, 25% anaplastic astrocytoma) suitable for high-dose therapy were selected for treatment with accelerated hyperfractionated radiotherapy, 1.5 Gy twice daily to a total target dose of 60 Gy. Two patients were excluded from analysis (one patient had a fatal pulmonary embolism after 18 Gy; one patient discontinued therapy after 28.5 Gy against medical advice and without sequelae or progression). The 68 patients in the study group had a median age of 52 years and a median Karnofsky performance status of 90. Stereotactic implant (125I) or stereotactic radiosurgery boosts were delivered to 16 patients (24%) in the study group. Minimum follow-up was 6 months. RESULTS: Median survival was 13.8 months and median progression-free survival was 7.4 months. The absolute Kaplan-Meier survival rate was 16% at 2 years and 4% at 5 years. Multivariate analysis for the prognostic impact of age, gender, histology, Karnofsky performance status, symptomatology, surgical resection vs. biopsy, and boost vs. nonboost therapy revealed that Karnofsky performance status > or = 90, boost therapy, and surgical excision predicted significantly improved outcome. No severe toxicity occurred in patients treated with accelerated hyperfractionated radiotherapy alone, although 5% required steroids temporarily for edema. Progression occurred during treatment in one patient (1.5%). CONCLUSION: This regimen of accelerated hyperfractionated radiotherapy is well tolerated and leads to results comparable with those of standard therapy. The rate of disease progression during treatment is significantly better (p = 0.001) than is reported for patients treated with standard fractionation, with or without chemotherapy. This regimen is a reasonable starting point for future trials and may have some advantages over standard fractionation.

Adolescent↗

The lazaroid U74389G protects normal brain from stereotactic radiosurgery-induced radiation injury.

PURPOSE: To test an established model of stereotactic radiosurgery-induced radiation injury with pretreatments of either methylprednisolone or the lazaroid U74389G. METHODS AND MATERIALS: Nine cats received stereotactic radiosurgery with a linear accelerator using and animal radiosurgery device. Each received a dose of 125.0 Gy prescribed to the 84% isodose shell to the anterior limb of the right internal capsule. One animal received no pretreatment, two received citrate vehicle, three received 30 mg/kg of methylprednisolone, and three received 5 mg/kg of U74389G. After irradiation, the animals had frequent neurologic examinations, and neurologic deficits developed in all of them. Six months after the radiation treatment, the animals were anesthetized, and had gadolinium-enhanced magnetic resonance (MR) scans, followed by Evans blue dye perfusion, euthanasia, and brain fixation. RESULTS: Magnetic resonance scans revealed a decrease in the size of the lesions from a mean volume of 0.45 +/- 0.06 cm(3) in the control, vehicle-treated, and methylpredniosolone-treated animals to 0.22 +/- 0.14 cm(3) in the U74389G-treated group. The scans also suggested the absence of necrosis and ventricular dilatation in the lazaroid-treated group. Gross pathology revealed that lesions produced in the untreated, vehicle-treated, and methylprednisolone-treated cats were similar and were characterized by a peripheral zone of Evans blue dye staining with a central zone of a mature coagulative necrosis and focal hemorrhage. However, in the U74389G-treated animals, the lesions were found to have an area of Evans blue dye staining, but lacked discrete areas of necrosis and hemorrhage. CONCLUSION: These results suggest that the lazaroid U74389G protects the normal brain from radiation injury produced by stereotactic radiosurgery.

Animals↗