Efficacy and safety of monophasic and biphasic waveform shocks using a braided endocardial defibrillation lead system.

Endocardial lead systems for implantable cardioverter-defibrillators utilize large (12F) rigid catheters with spring defibrillation electrodes, and lead system failure has been observed during long-term implant. We evaluated a novel flexible 8F braided electrode catheter for pacing and defibrillation in canine experiments. Active fixation and pacing were accomplished using a screw-in distal electrode, and defibrillation pulses were delivered through a braided electrode. Two braided electrode catheters were positioned in the right ventricular apex (6 cm2) and in the superior vena cava-right atrial junction (5 cm2), respectively. An elliptical 13 cm2 surface area patch electrode was positioned along the left lateral cardiac border. Ventricular fibrillation (VF) was induced and monophasic and asymmetric biphasic shocks (leading voltages 260 to 1000 V) were delivered via dual and triple electrode configurations in each animal using a prospective randomized crossover study design. Mean right ventricular pacing threshold was 0.5 +/- 0.2 mA, with a mean electrogram amplitude of 11.1 +/- 2.8 mV during sinus rhythm prior to fibrillation and defibrillation. Two hundred seven VF inductions (mean 30 +/- 4 per animal) were analyzed. The mean defibrillation threshold could be reduced to 8.0 +/- 3.2 joules with biphasic shocks from 12.9 +/- 5.1 joules obtained for monophasic shocks using a dual electrode system (p less than 0.004). Mean shock leading voltage was correspondingly reduced to 488 +/- 100 V from 691 +/- 154 V (p less than 0.0006).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Atrial capture detection with endocardial electrodes.

A new method of evoked response detection, previously demonstrated in the ventricle, has been studied in the atrium at the time of routine pacemaker implant in 16 patients. The atrial evoked response was readily detectable in all patients due to excellent recovery from poststimulus polarization. In six patients, as experimental threshold-tracking pacemaker was used to automatically verify atrial capture and to generate strength-duration curves. It is concluded that this pacing technique is both simple and reliable, and that automatic atrial threshold tracking is feasible.

Atrial Function↗

The relationship between arterial pulse-wave velocity and pulse frequency at different pressures.

Pulse-wave velocity was measured in isolated canine common carotid arteries using sinusoidal frequency pulses of 1, 2, 5, 10, 15 and 20 Hz at 50, 100 and 150 mmHg. It was found that the pulse-wave velocity was independent of frequency and dependent on pressure. Using the Moens-Korteweg equation, the predicted pulse-wave velocity (y) was compared with measured pulse-wave velocity (x). A good correspondence was found (y = 1.063 x - 0.337, with a correlation coefficient of 0.963). The propagation velocity of the significant harmonic components of the pulsatile pressure waveform is the same for heart rates up to 120 beats/min.

Animals↗