PubMed Health⌕ Search

Biomedical subjects

F J Criado

Publications and source records attributed to F J Criado.

At least 19 recordsLinked to original sources

Endograft repair of acute aortic dissection. Promises and challenges.

Acute dissection is a uniquely complex, relatively common, and frequently lethal aortic catastrophe. Historically, surgical treatment has been reserved for cases with complications including rupture; the results have been less than optimal because of excessive morbidity and mortality. This is the main reason why conservative management emerged as the standard of care for management of acute type B aortic dissection (TBAD). While more patients would appear to survive with a conservative treatment strategy, the outcome in terms of 30-day mortality (20%) and occurrence of late complications - such as enlarging aneurysms of the thoracic false lumen (30-40%) - leaves (again) much to be desired. Stent-graft endovascular repair has emerged as a very promising, less invasive treatment option. These devices, when used appropriately, can achieve the important therapeutic goals of entry-site coverage, depressurization of the false lumen, and expansion of the compressed true lumen - overcoming ischemic (malperfusion) manifestations. The early results of stent-graft repair of TBAD are encouraging, and even exciting, but much more work needs to be done in various critical areas surrounding this condition. Thoracic endograft technology has lagged behind its abdominal counterpart. The design of acute dissection-specific devices is imperative, reflecting the significant differences between TBAD and degenerative thoracic aortic aneurysm disease. Needs for this and other important developments notwithstanding, it is generally acknowledged that stent-graft intervention does represent an important advance in the treatment of patients with TBAD. Well-designed, controlled clinical trials will be necessary to elucidate the relative value of several endovascular thoracic strategies.

Acute Disease↗

Update on the Talent aortic stent-graft: a preliminary report from United States phase I and II trials.

PURPOSE: Phase I and phase II trials were conducted to determine the safety and efficacy of the Talent aortic stent-graft (Medtronic World Medical, Sunrise, Fla) in the treatment of infrarenal abdominal aortic aneurysms (AAA). This is a preliminary report of the technical results and 30-day clinical outcome of these trials. METHODS: Multicenter prospective trials were conducted to test the Talent stent-graft in high-risk and low-risk patient populations with AAA, including phase I feasibility and phase II clinical trials. The low-risk study included concurrent surgical controls. RESULTS: In the phase I trial, deployment success was achieved in 92% (23/25 patients), and initial technical success was 78% (18/23 implants without endoleak). The 30-day technical success rate was 96%, with six endoleaks that resolved spontaneously (without need for further intervention); and the 30-day mortality rate was 12% (3/25 patients). The phase II high-risk trial demonstrated a deployment success of 94% (119/127 patients) and an initial technical success of 86% (102/119 implants). The 30-day technical success rate was 96%, and the 30-day mortality rate was 1.5% (2/127 patients). The phase II low-risk trial included a first-generation and a second-generation Talent stent-graft. Deployment success rates were 97% and 99%, respectively, and technical success rates at 30 days were 97% and 96%, respectively. The 30-day mortality rate was 2% in the phase II low-risk first-generation device trial, and the adverse-event rate was 20%. Corresponding figures for the second-generation device were 0% and 1.8%, respectively. CONCLUSION: The Talent stent-graft can be deployed successfully and achieves endovascular exclusion in a large proportion of patients with AAA. Morbidity and mortality rates are acceptable. One-year clinical results and the comparison with concurrent surgical control subjects remain to be evaluated.

Angioplasty↗

Relationship between preoperative patency of the inferior mesenteric artery and subsequent occurrence of type II endoleak in patients undergoing endovascular repair of abdominal aortic aneurysms.

OBJECTIVES: The purpose of this study was (1) to find out whether preoperative inferior mesenteric artery (IMA) patency (on radiographic imaging) predicts IMA-related endoleaks after endovascular repair of infrarenal abdominal aortic aneurysms, (2) to determine feasibility of measuring aneurysm sac pressures in patients with endoleaks, and (3) to report early evidence of effective endovascular obliteration of IMA endoleaks. METHODS: We studied 76 consecutive cases of infrarenal aortic aneurysms that were repaired with an endovascular approach (March 1998-April 1999). RESULTS: There were 13 (17%) endoleaks persistent 30 days after the procedure. Eleven (85%) of these 13 were IMA-related endoleaks, which were documented with selective superior mesenteric artery angiography. The preoperative finding (on computed tomographic scan) of a patent IMA does not always predict an IMA-related endoleak, but results in a statistically and clinically significant higher ratio of patients with IMA-related endoleaks in the immediate postoperative period (24% versus 3%, P <.035). In eight of the 11 patients with persistent IMA-related endoleaks, measurement of intra-aneurysm sac pressures was possible, and six of these patients had systemic pressures within the excluded aneurysm sac. Nine (82%) of 11 IMA-related endoleaks were successfully obliterated by means of selective IMA embolization. CONCLUSIONS: Many endoleaks are caused by a patent IMA, and this can result in persistence of systemic pressure within the aneurysm sac. The preoperative finding (on computed tomographic scan) of a patent IMA is a predictor of increased rates of IMA endoleaks, and IMA endoleaks can be successfully obliterated through endovascular procedures, after endovascular abdominal aortic aneurysm repair.

Aortic Aneurysm, Abdominal↗

Brachial artery catheterization to facilitate endovascular grafting of abdominal aortic aneurysm: safety and rationale.

PURPOSE: Endovascular treatment of abdominal aortic aneurysms (AAAs) is a technically demanding procedure that is based on the complexity and multiplicity of steps and the guidewire and catheter manipulations required. Brachial artery catheterization is an adjunctive technique that can facilitate the placement of an endoluminal prosthesis. METHODS: Brachial access was used during endoluminal AAA repair in 79 of 103 consecutive patients with a modular-design stent-graft prosthesis at two institutions. RESULTS: Left brachial access facilitated (1) angiography to guide juxtarenal device deployment, (2) antegrade contralateral limb access, (3) device delivery through disadvantaged iliac arteries by means of a brachial femoral wire, (4) access to renal arteries when necessary, and (5) catheter exchanges and a reduction in fluoroscopic positional changes. Complications included one puncture-site pseudoaneurysm, seven hematomas, and 29 patients with extensive ecchymosis. The length of stay was not prolonged in any case. There were no embolic, oculocerebral, or ischemic upper extremity events. CONCLUSIONS: Brachial artery catheterization, as an adjunctive technique to endoluminal AAA repair, offers noteworthy technical advantages with few, but self-limiting complications.

Angiography↗

Safety of coil embolization of the internal iliac artery in endovascular grafting of abdominal aortic aneurysms.

PURPOSE: During endovascular grafting of an abdominal aortic aneurysm (AAA), iliac limb extension to the external iliac artery may be indicated when the common iliac artery is ectatic or aneurysmal. Preliminary or concomitant coil embolization of the internal iliac artery (IIA) is thus necessary to prevent potential reflux and endoleak. We sought to determine the safety of hypogastric flow interruption in this setting. METHODS: We retrospectively reviewed 156 patients who underwent stent-graft AAA repair at two institutions between February 1, 1998, and January 31, 1999. Coil embolization of one or both IIAs was undertaken when the diameter of the common iliac artery was more than 20 mm to enable limb endograft extension to the external iliac artery. Bilateral procedures were staged. RESULTS: Thirty-nine (25%) of 156 patients were selected for coil embolization of one (n = 28) or both (n = 11) IIAs. The interventions were performed before (n = 31) or during (n = 8) the stent-graft procedure. Complications included groin hematomas in 3 patients, iliac artery dissection in 1, failure to catheterize the IIA in 2, and transient rise in the serum creatinine level in 3. One patient had erectile dysfunction, and five patients (13%) had buttock claudication after unilateral occlusion. Serious ischemic complications were not observed. CONCLUSION: Coil embolization of one or both IIAs appears to be safe in the setting of endovascular grafting of AAA. Buttock claudication is a relatively significant problem and may limit applicability of this strategy to patients who are unfit for standard open repair.

Aged↗