PubMed Health⌕ Search

Biomedical subjects

F J Hans

Publications and source records attributed to F J Hans.

At least 19 recordsLinked to original sources

Magnetic versus manual guidewire manipulation in neuroradiology: in vitro results.

INTRODUCTION: Standard microguidewires used in interventional neuroradiology have a predefined shape of the tip that cannot be changed while the guidewire is in the vessel. We evaluated a novel magnetic navigation system (MNS) that generates a magnetic field to control the deflection of a microguidewire that can be used to reshape the guidewire tip in vivo without removing the wire from the body, thereby potentially facilitating navigation along tortuous paths or multiple acute curves. METHOD: The MNS consists of two permanent magnets positioned on either side of the fluoroscopy table that create a constant precisely controlled magnetic field in the defined region of interest. This field enables omnidirectional rotation of a 0.014-inch magnetic microguidewire (MG). Speed of navigation, accuracy in a tortuous vessel anatomy and the potential for navigating into in vitro aneurysms were tested by four investigators with differing experience in neurointervention and compared to navigation with a standard, manually controlled microguidewire (SG). RESULTS: Navigation using MG was faster (P=0.0056) and more accurate (0.2 mistakes per trial vs. 2.6 mistakes per trial) only in less-experienced investigators. There were no statistically significant differences between the MG and the SG in the hands of experienced investigators. One aneurysm with an acute angulation from the carrier vessel could be navigated only with the MG while the SG failed, even after multiple reshaping manoeuvres. CONCLUSION: Our findings suggest that magnetic navigation seems to be easier, more accurate and faster in the hands of less-experienced investigators. We consider that the features of the MNS may improve the efficacy and safety of challenging neurointerventional procedures.

Catheterization↗

Silent microemboli related to diagnostic cerebral angiography: a matter of operator's experience and patient's disease.

INTRODUCTION: The aim of the present investigation was to elucidate in a large consecutive patient cohort whether the level of training has an effect on the number of microemboli detected by diffusion-weighted imaging (DWI) and which additional risk factors can be identified. METHODS: A total of 107 consecutive patients in whom a diagnostic cerebral angiography had been performed were prospectively investigated with DWI; 51 angiographies were performed by experienced neuroradiologists, 56 by neuroradiologists in training. RESULTS: In 12 patients (11.1%), a total of 17 new lesions without any clinically overt neurological symptoms were identified. Of these, 12 patients, 11 (91.7%) with 16 lesions were investigated by junior neuroradiologists. In 11 of 12 patients with DWI abnormalities (91.7%), risk factors could be identified (atherosclerotic vessel wall disease, vasculitis, hypercoagulable states). Experienced neuroradiologists performed 21 of 48 angiographies (43.8%) on patients with the above-mentioned risk factors, whereas junior neuroradiologists performed 27 angiographies in this subgroup (46.2%). The rate of diffusion abnormalities in patients with risk factors was 11/48 (22.9%) - considerably higher than in patients without risk factors (1/59; 1.7%). CONCLUSION: The level of experience and the nature of the underlying disease are predictors of the occurrence of cerebral ischemic events following neuroangiography. Alternative diagnostic modalities should be employed in patients who are investigated for diseases with the highest risk of angiographic complications (i.e., vasculitis, and arteriosclerotic vessel wall disease). If diagnostic angiography remains necessary in these patients, the highest level of practitioner training is necessary to ensure good patient outcome.

Adolescent↗

Technical pitfalls in a porcine brain retraction model. The impact of brain spatula on the retracted brain tissue in a porcine model: a feasibility study and its technical pitfalls.

We describe technical pitfalls of a porcine brain injury model for identifying primary and secondary pathological sequelae following brain retraction by brain spatula. In 16 anaesthetised male pigs, the right frontal brain was retracted in the interhemispheric fissure by a brain spatulum with varying pressures applied by the gravitational force of weights from 10 to 70 g for a duration of 30 min. The retracted brain tissue was monitored for changes in intracranial pressure and perfusion of the cortex using a Laser Doppler Perfusion Imager (MoorLDI). To evaluate the extent of oedema and cortical contusions, MRI was performed 30 min and 72 h after brain retraction. Following the MR scan, the retracted brain areas were histopathologically assessed using H&E and Fluoro-Jade B staining for neuronal damage. Sinus occlusion occurred in four animals, resulting in bilateral cortical contusions and extensive brain oedema. Retracting the brain with weights of 70 g (n = 4) caused extensive oedema on FLAIR images that correlated clinically with a hemiparesis in three animals. Morphologically, an increased number of Fluoro-Jade B-positive neurons were found. A sequential decrease in weights prevented functional deficits in animals. A retraction pressure applied by 10-g weights (n = 7) caused a mean rise in intracranial pressure to 4.0 +/- 3.1 mm Hg, and a decrement in mean cortical perfusion from 740.8 +/- 41.5 to 693.8 +/- 72.4 PU/cm2 (P < 0.24). A meticulous dissection of the interhemispheric fissure and a reduction of weights to 10 g were found to be mandatory to study the cortical impact caused by brain spatula reproducibly.

Analysis of Variance↗

Primary lymphoma of the skull base.

This case demonstrates the rare finding of a primary malignant lymphoma of the frontobasis and ethmoidal cells in a patient presenting with progressive loss of vision. Computed tomography and MRI demonstrated a homogenously enhancing tumour with extensive bony destructions of the skull base. After transsphenoidal biopsy, histology revealed a highly malignant primary B-cell lymphoma. The patient was further treated with immunochemotherapy. Tissue diagnosis is, therefore, crucial before a definitive therapy is instituted.

Biopsy↗

Treatment of wide-necked aneurysms with balloon-expandable polyurethane-covered stentgrafts: experience in an animal model.

OBJECTIVE: Endovascular treatment of intracranial wide-necked aneurysms employing stentgrafts might constitute a promising alternative to established neurosurgical or endovascular treatment options. However, there is uncertainity concerning long-term vessel patency and biocompatibility of the covering material used for these stentgrafts. The objective of our study was, therefore, to evaluate in an animal model of wide necked aneurysms, which changes within the parent vessel wall are present after stentgraft placement using polyurethane as the covering material. METHODS: Wide-necked aneurysms were created in rabbits by distal ligation and intraluminal incubation of the right common carotid artery with elastase. All 10 animals were treated with polyurethane covered stentgrafts. Angiography and histological analyses were performed including immunohistochemical investigations for estimating the proliferation of the intima and possible inflammatory infiltration of the vessel wall after one (n = 5) and three months (n = 5) observation. RESULTS: Stentgrafts led to a complete and stable aneurysm occlusion in all but one animal in which the stent was initially misplaced. In one animal, the stentgraft was completely occluded as visible both at angiography and on histological examination. Here, old thrombus was found within the stent although the animal was on antiplatelet therapy. The other stentgrafts remained patent and demonstrated only minimal proliferative carrier vessel wall changes and no in-stent stenosis. CONCLUSIONS: In previous animal models using Dacron covered stentgrafts, a poor short term patency rate due to the limited biocompatibility was found. We found, that Polyurethane seemed to have less adverse effects upon the vessel wall. However, a longer follow-up period is necessary to exclude delayed stenosis of the parent vessels. Stentgrafts may, therefore, play a role in broad based aneurysms, dissecting aneurysms or pseudoaneurysms, however, vessel sacrifice using permanent balloon occlusion may be a safer and better established alternative compared to the use of stentgrafts.

Aneurysm↗

Clinical applications of 2-D dynamic contrast-enhanced MR subtraction angiography in neurosurgery -- preliminary results.

OBJECTIVES: Advances in MR hardware performance and imaging techniques have enabled us to perform sub-second frame rate contrast enhanced MR angiographies as a clinical routine, resulting in subtraction angiographies with temporal resolutions similar to those obtained by conventional DSA. In this manuscript, we describe the technique of 2-D dynamic contrast-enhanced MR subtraction angiography and its possible applications in neurosurgery. METHODS: A T (1)-weighted gradient-echo sequence with short TR and TE values was performed during the intravenous bolus application of MR contrast media. This sequence had a temporal resolution of up to 0.34 seconds per image and was performed in 28 patients harbouring arteriovenous malformations (n = 12), dural AV fistulas (n = 3), meningiomas (n = 8), glomus tympanicum or jugulare tumours (n = 3), and haemangioperizytomas (n = 2). Arterial digital subtraction angiography (DSA) was performed in all patients and compared to the MRA sequences with respect to differentiation into early, late arterial and venous phases, detectability of normal vessels, detection of the pathology, feeding arteries, capillary blush, early draining veins, and hyper-vascularization. RESULTS: In all 28 investigated cases and all pathological entities separation of early and late arterial phases, capillary phases, early and late venous phases was possible. The proximal portions of the major cerebral arteries, the capillary blush and the venous anatomy including the tributaries to the large sinuses could be well defined and correlated well with the gold standard, i. e. DSA. CONCLUSIONS: Dynamic contrast enhanced MR angiography will prove helpful in 1) the follow-up of AVMs since early venous drainage can be visualised; 2) the demonstration of dural AVF, which can be recognised as an early filling of a dural sinus during the early arterial phase; and 3) the characterisation of the degree of vascularisation of brain tumours.

Adult↗

Spontaneous regression of two supraophthalmic internal cerebral artery aneurysms following flow pattern alteration.

We report on a patient with fibromuscular dysplasia who presented with a right-sided giant calcified cavernous internal carotid artery (ICA) aneurysm and two additional supraophthalmic ICA aneurysms. Endovascular closure of the right ICA using detachable balloons was performed with collateralisation of the right hemisphere via the right-sided posterior communicating and the anterior communicating arteries. Repeat angiography after 6 months demonstrated spontaneous complete regression of the two supraophthalmic aneurysms, although the parent vessel was still perfused. In comparison to the former angiography, the flow within the parent vessel was reversed due to the proximal ICA balloon occlusion. MRI demonstrated that the aneurysms were not obliterated by thrombosis alone, but showed a real regression in size. This case report demonstrates that changes in cerebral hemodynamics potentially lead to plastic changes in the vessel architecture in adults and that aneurysms can be flow-related, even if not associated with high flow fistulas or arteriovenous malformations, especially in cases with an arterial wall disease.

Aged↗

Are the configuration and neck morphology of experimental aneurysms predictable? A technical approach.

Aneurysm configuration and neck morphology are important factors in the decision for cerebral aneurysm therapy, i.e., clipping versus coiling. The aim of our study was to create various aneurysm configurations in a predictable and reproducible way in an animal model. In our recently proposed endovascular approach to produce bifurcation aneurysms in the rabbit, the right common carotid artery (CCA) is surgically exposed and distally ligated, and a sheath is advanced retrogradely into the CCA, the base of which is proximally occluded using a Fogarty balloon. Subsequently, elastase is injected via a microcatheter that is placed directly distal to the balloon and allowed to incubate for 20 min. After removal of the sheath, saccular aneurysms begin to form within 2 weeks. For greater variability in aneurysm size and neck morphology, we modified two parameters of this formerly established elastase-induced aneurysm model--the distance between the balloon and sheath and the level of balloon position--before the elastase was endoluminally incubated in 15 rabbits. Three weeks after aneurysm induction, the size and configuration of the aneurysms were controlled using DSA. Our results confirm that balloon occlusion in the brachiocephalic trunk results in broad-based aneurysms, whereas balloon occlusion in the CCA gives rise to circumscribed aneurysm necks. By increasing the distance between the balloon and sheath, the rabbits developed significantly larger aneurysms. The balloon-sheath distance and the level of balloon occlusion proved to be parameters whose modifications result in predictable and reproducible aneurysm variants that can be used for the testing of endovascular devices.

Animals↗

Detection of intracranial aneurysms with multislice CT: comparison with conventional angiography.

We assessed the diagnostic accuracy of multislice CT in detection of intracranial aneurysms in patients presenting with subarachnoid or intracranial haemorrhage. Multislice CT and multiplanar digital subtraction angiography (DSA) images were obtained in 50 consecutive patients presenting with subarachnoid (SAH) and/or intracranial haemorrhage and reviewed by three neuroradiologists for the number, size and site of any aneurysms. The CT data were assessed using multiplanar reformats (MPR), maximum-intensity projections (MIP), surface-shaded display (SSD) and volume-rendering (VRT). In conventional angiography 51 aneurysms were detected in 41 patients. CT angiography (CTA) showed up to 48 aneurysms in 39 patients, depending on the observer. The overall sensitivity of multislice CT was 83.3% for small (< 4 mm), 90.6% for medium-size (5-12 mm) and 100% for large (> 13 mm) aneurysms. The sensitivity of multislice CTA to medium-size and large intracranial aneurysm is within the upper part of the range reported for helical single-slice CT. However, as small aneurysms may not be found, DSA remains the standard technique for investigation of SAH.

Angiography, Digital Subtraction↗

Haemorrhagic tracheal necrosis as a lethal complication of an aneurysm model in rabbits via endoluminal incubation with elastase.

BACKGROUND: We describe a lethal complication of an aneurysm model in rabbits for saccular aneurysmal creation via endoluminal incubation with elastase. METHOD: In 24 anaesthetized female New Zealand White rabbits, the right common carotid artery (CCA) was ligated distally to the arteriotomy. A 4F sheath was then placed retrograde into the CCA, and its origin was occluded endoluminally using a 2F Fogarty balloon. Elastase was incubated above the balloon in the separated vessel lumen for the duration of 20 minutes. Two weeks later, digital subtraction angiography was performed for aneurysm control. Two animals were then sacrificed and the aneurysm studied on histology. All animals that died within the experiment were examined post-mortem. FINDINGS: Following this protocol, an aneurysm with a mean size of 7.6 x 3.2 mm could be created in 11 out of 24 animals. 9 out of 13 animals with lethal outcome died from haemorrhagic necrosis of the trachea with subsequent pulmonary complications. DSA releaved an arterial branch originating from the proximal CCA in a near 90 degree-angle aiming at the trachea. INTERPRETATION: The endoluminal incubation with elastase is suitable for aneurysm creation of reproducible size that are suited to test new endovascular devices such as stents and new coils. One should always be aware of an arterial branch of the CCA supplying the trachea. In case of elastase instillation into this branch, lethal haemorrhagic necrosis of the trachea occurs. Bearing this complication in mind, we have experienced a minimal loss of animals in subsequent studies.

Animals↗

Lumbar nerve root avulsion following trauma: balanced fast field-echo MRI.

Lumbosacral nerve root avulsion uncommonly complicates major trauma. Most patients also have pelvic or lumbar fractures. We present a patient who had a high-velocity vehicle accident with traumatic hip dislocation without fractures of the spine or pelvis. MRI demonstrated lumbosacral traumatic pseudomeningoceles. We used balanced fast field echo and MR myelography to make the diagnosis and show the extent of the pseudomeningocele.

Adult↗

Endovascular treatment of experimentally induced aneurysms in rabbits using stents: a feasibility study.

Although Guglielmi detachable coil (GDC) systems have been generally accepted for treatment of intracranial aneurysms, primary stenting of aneurysms using porous stents or implantation of coils after stent placement remains experimental. Testing of these new methods requires an animal model which imitates human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements of and steps for transfemoral stent treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk in rabbits. We created aneurysms in ten rabbits by distal ligation and intraluminal digestion of the right common carotid artery with elastase. We treated five animals with porous stents alone, and five with stents plus coiling via the meshes of the stent, which permitted dense packing of coils. No complications related to the procedures occurred. In all animals, even in those treated solely with porous stents, total occlusion of the aneurysm was achieved. Our animal model can be suitable for testing the biocompatibility and occlusion rate of new methods and devices for the treatment of experimental aneurysms.

Aneurysm↗

Endovascular treatment of experimental aneurysms in rabbits using Guglielmi detachable coils -- a feasibility study.

The Guglielmi detachable coil (GDC) has been generally accepted for treatment of intracranial aneurysms. Preclinical testing of new coil developments requires animal models of aneurysms which imitate human aneurysms in size, configuration and neck morphology. We assessed in detail the technical requirements and steps for transfemoral treatment of experimentally induced aneurysms at the top of the brachiocephalic trunk (TBC) in rabbits. We created aneurysms in five rabbits by distal ligation and intraluminal incubation of the right common carotid artery with elastase. All animals were treated successfully 2-3 weeks after induction of the aneurysm, with dense packing of the coils. No complications related to the procedures occurred. The study demonstrates that our animal model can be a suitable method for testing the biocompatibility and occlusion rate of new embolic materials.

Aneurysm↗

[Pterional orbital decompression in traumatic orbital hematomas].

The results are presented for pterional orbital decompression in 12 patients with symptomatic traumatic retrobulbar hematoma after various traumatic mechanisms. Pre- and postoperative course, neuroradiological findings, additional brain or facial injuries as well as outcome of eye function are analyzed in detail. Mean time delay between trauma and decompression was 56 h (2.4 days), with a wide range from 2 h to 15 days. Preoperative exophthalmos and pupillary disturbances as well as restrictions of extraocular movements decreased in all patients after orbital decompression and removal of the retrobulbar hematoma if the bleeding was localized. Visual acuity remained normal or showed significant improvement in seven patients, four of whom experienced complete recovery. In three patients the eye remained amaurotic. No complications related to the operation were seen. The pterional orbital decompression described here represents an effective alternative approach for patients with sight-threatening retrobulbar hematoma, especially in cases where it is necessary to gain space for the orbit in addition to evacuating space-occupying blood or bone clots and treating neighbouring lesions. Immediate detection and adequate treatment of orbital hematomas is mandatory to achieve an acceptable outcome of eye function.

Adolescent↗

Functional MRI and 18F FDG-positron emission tomography for presurgical planning: comparison with electrical cortical stimulation.

BACKGROUND: In patients with mass lesions near "eloquent" cortical areas different preoperative mapping techniques can be used. Two of the most widely used approaches include positron emission tomography (PET) and functional MRI (fMRI). We employed both methods in the same patients undergoing presurgical evaluation and compared the results to those obtained by direct electrical cortical stimulation (DECS). METHOD: 22 patients with tumours of different aetiology near the central region were investigated. FMRI was performed using a T2(*)-weighted gradient-echo BOLD sequence at 1.5 T, PET was performed after injection of 122-301 MBq (18)F-Fluorodeoxyglucose (18-FDG) under rest and activation conditions. DECS was performed in all patients with recordings of muscles primarily involved in the investigated tasks. FINDINGS: In 19 patients all three modalities could be compared, 1 patient demonstrated discordance between fMRI and PET with DECS speaking in favour of fMRI, 6 patients had neighbouring results of PET and fMRI (between 1-2 cm distance), 12 patients had overlapping results. INTERPRETATION: The high incidence of neighbouring results is presumably related to fMRI specific artefacts. Advantages of fMRI are: Higher spatial and temporal resolution, more and different functional runs, shorter examination time, wider availability, longitudinal examinations, non-invasiveness and cost-effectiveness, easy registration to anatomical images. Advantages of PET are: higher signal-to-noise ratio, lesser susceptibility to artefacts (motion, draining veins), evaluation of tumour metabolism. It is our opinion that the neurosurgeon has to decide on a case-by-case basis which study suits his specific needs in the presurgical evaluation of his patient.

Adult↗

Movement artefacts and MR BOLD signal increase during different paradigms for mapping the sensorimotor cortex.

BACKGROUND: The authors evaluated the impact of motion artefacts on presurgical mapping of the sensorimotor cortex with functional magnetic resonance imaging (fMRI). Different mapping paradigms were compared with regard to the frequency of motion artefacts and the resulting signal increase. METHOD: 94 surgical candidates with mass lesions near the central region were investigated using BOLD(1)-contrast T2(*) weighted multislice multi-echo EPI gradient echo sequences on a 1,5 T Philips Gyroscan. Three functional paradigms were performed: a) repetitive self-paced clenching of the hand to a fist (68 runs); b) repetitive finger-to-thumb opposition (46 runs); c) sensory stimulation by repetitive brushing of the palm (15 runs). Task-related haemodynamic changes were identified by statistical analysis with the Kolmogorov-Smirnov-test. MR signal increase in percent was calculated for each of the paradigms. Motion artefacts were rated on a scale from 1 to 3. FINDINGS: Severe motion artefacts occurred in 8 hand clenching runs and in 2 finger opposition runs. Artefacts were more pronounced in hand clenching than in finger opposition. There were no motion artefacts in any of the sensory stimulation runs. Concerning the percent MR signal change there was no significant difference between hand clenching and finger opposition (T-test: p>0,5) but a highly significant difference (p<0,0001) between both motor tasks and the sensory paradigm (hand clenching: 2.68+/-0.75; finger opposition: 2.76+/-0.79; sensory stimulation: 1.72+/-0.65). INTERPRETATION: Sensory stimulation causes by far less artefacts than motor paradigms but it also has to be considered less sensitive as it produces a smaller MR signal increase. Therefore in presurgical evaluation sensory stimulation should be kept in reserve for cases in whom motion artefacts are very likely to occur, i.e. patients with severe forms of paresis.

Adolescent↗

Is the head position during preoperative image data acquisition essential for the accuracy of navigated brain tumor surgery?

OBJECTIVE: To analyze the influence of head positioning during preoperative image data acquisition on intraoperative accuracy of modern neuronavigation systems. MATERIAL AND METHODS: All measurements were performed preoperatively before opening the head. In 24 patients, preoperative MR image data acquisition was performed twice on a 0.5 T scanner using a contrast-enhanced T1-weighted sequence; first in the neutral head position, and thereafter in the surgical head position for pterional craniotomy. For both data sets, the Sylvian fissure, the central sulcus, and the superior and inferior temporal sulci were depicted on the patient's scalp using the frameless neuronavigation system EasyGuide Neurotrade mark. At the beginning of surgery, with the head fixed in a Mayfield clamp and an articulated instrument holder being used for fixation of the navigation system's pointer, the distances of 10 correlating points of the sulci for the two data sets were measured. To evaluate the accuracy of the navigation system in this experimental set-up, a phantom study was also performed. RESULTS: The phantom study revealed a mean inaccuracy of 1.6 mm (range 0.1-2.3 mm, standard deviation 0.6 mm). The patient study revealed a mean inaccuracy of 1.8 mm (range 0.4-2.8 mm, standard deviation 0.5 mm). CONCLUSIONS: The data suggest that the positioning of the patient's head during preoperative imaging plays no relevant role in intraoperative accuracy of neuronavigation. However, further studies and a larger number of patients with various pathologies in different regions of the brain are necessary to obtain a better understanding of the problem of brain shift in neuronavigation due to patient positioning alone, and to avoid procedure-related operative morbidity.

Adult↗