PubMed Health⌕ Search

Biomedical subjects

F J Monteiro

Publications and source records attributed to F J Monteiro.

18 recordsLinked to original sources

Development of a system to adsorb drugs onto calcium phosphate materials.

Several studies were carried out in order to reduce the systemic use of antibiotics due to the high concentration required to provide the minimum inhibitory concentration (MIC) at infected sites. The aim of this study was to develop a system of drug adsorption onto commercial hydroxyapatite (HA, Ca10(PO4)6(OH)2) and glass reinforced hydroxyapatite (GR-HA) granules. The drug will then be released for the local treatment of periodontitis. The antibiotics used in this study were metronidazole, a specific antibiotic indicated for the systemic treatment of periodontitis, and ampicillin, a wide spectrum antibiotic. UV spectroscopy was used to measure the amount of drug adsorbed onto HA and GR-HA granules. Results showed that metronidazole was unable to adsorb on the material's surface, as opposed to ampicillin which adsorbed both onto HA and GR-HA. Preliminary release kinetics studies were carried out using a flow through dissolution system. Results are discussed in terms of the influence of the different surface characteristics of the materials on the adsorption processes.

Adsorption↗

Push-out testing and histological evaluation of glass reinforced hydroxyapatite composites implanted in the tibia of rabbits.

In vitro and in vivo bioactivity studies were performed to assess the biocompatibility of CaO-P2O5 glass-reinforced hydroxyapatite (GR-HA) composites. The ability to form an apatite layer by soaking in simulated body fluid (SBF) was examined and surfaces were characterized using FTIR reflection and thin-film X-ray diffraction analyses. Qualitative histology, histomorphometric measurements, and push-out testing were performed in a rabbit model for characterizing bone/implant bonding. Under the in vitro conditions using SBF, an apatite layer could not be formed on GR-HA composites within 8 weeks. Results of push-out testing showed bonding between the composites and bone, ranging from 130-145 N after 2 weeks of implantation. After the longest implantation period, 16 weeks, the GR-HA composite prepared with the higher content of CaO-P2O5 glass showed the highest bonding force, 606 +/- 45 N, compared to 459 +/- 30 N for sintered HA. Development of immature bone and modifications in the turnover of a more mature bone on the surface of GR-HA composites were similar to those on sintered HA.

Animals↗

Adsorption and release studies of sodium ampicillin from hydroxyapatite and glass-reinforced hydroxyapatite composites.

As a potential therapy for periodontitis, sodium ampicillin, a broad spectrum antibiotic, was adsorbed onto hydroxyapatite (HA) and glass-reinforced hydroxyaptite (GR-HA) composites, and was subsequently released in vitro. The sodium ampicillin, was adsorbed more on HA compared to the GR-HA composites. X-ray diffraction (XRD) and Rietveld analysis were used to identify and quantify the levels of HA and beta-tricalcium phosphate (beta-TCP) in the microstructure of the GR-HA composites. Lattice parameters changes were observed for the beta-TCP phase dependant on the amount of glass added. The release kinetics were shown to be divided into three stages, the first of which where a large amount of sodium ampicillin is released, followed by a slower release rate and then a final stage where the release amount approaches zero, until no more sodium ampicillin was present. X-ray photoeletron spectroscopy (XPS) studies were carried out in order to ensure that the entire antibiotic adsorbed onto the materials had been released. These kinetics studies have indicated the possibility of using these materials as possible carriers for drug delivery.

Adsorption↗

Effect of chemical composition on hydrophobicity and zeta potential of plasma sprayed HA/CaO-P2O5 glass coatings.

Multilayered plasma sprayed coatings on the surface of Ti-6Al-4V alloys have been prepared, which were composed of an underlayer of HA and a surface layer of a CaO-P2O5 glass-HA composite, with 2 or 4wt% of glass. Contact angle and surface tension variation with time, for both water and a protein solution, were determined by the sessile and pendent drop methods respectively using the ADSA-P software. Wettability studies showed that hydrophobicity of the coatings increase with the glass addition. The work of adhesion of albumin was also altered in a controlled manner by the addition of the CaO-P2O5 glass, being lower on the composite coatings than on HA. Zeta potential (ZP) results showed that composite coatings presented a higher net negative charge than HA coatings and that ZP values were also influenced by the content of the glass. This study demonstrated that the surface properties of those coatings may be modified by the addition of CaO-P2O5 glass.

Calcium Compounds↗

HA and double-layer HA-P2O5/CaO glass coatings: influence of chemical composition on human bone marrow cells osteoblastic behavior.

Human osteoblastic bone marrow derived cells were cultured for 28 days onto the surface of a glass reinforced hydroxyapatite (HA) composite and a commercial type HA plasma sprayed coatings, both in the "as-received" condition and after an immersion treatment with culture medium during 21 days. Cell proliferation and differentiation were analyzed as a function of the chemical composition of the coatings and the immersion treatment. Cell attachment, growth and differentiation of osteoblastic bone marrow cells seeded onto "as-received" plasma sprayed coatings were strongly affected by the time-dependent variation of the surface structure occurring during the first hours of culture. Initial interactions leading to higher amounts of adsorbed protein and zeta potential shifts towards negative charges appeared to result in surface structures with better biological performance. Cultures grown onto the pretreated coatings showed higher rate of cell proliferation and increased functional activity, as compared to those grown onto the corresponding "as-received" materials. However, the cell behavior was similar in the glass composite and HA coatings. The results showed that the glass composites present better characteristics for bone cell growth and function than HA. In addition, this work also provide evidence that the biological performance of the glass composites can be modulated and improved by manipulations in the chemical composition, namely in the content of glass added to HA.

Journal Article↗

Direct and indirect effects of P2O5 glass reinforced-hydroxyapatite composites on the growth and function of osteoblast-like cells.

Human osteoblast-like cells were plated on hydroxyapatite and P2O5-glass reinforced hydroxyapatite composite discs. They were also cultured in the presence of media obtained by incubating the discs in the absence of cells. The effects of these direct and indirect interactions were examined by measuring cell proliferation and the expression of certain key extracellular matrix antigens. One composite was found to initially delay cell growth, while the extract of a different composite appeared to down-regulate DNA synthesis. Flow cytometry analysis showed that growth directly on the discs had little effect on collagen type I, but reduced fibronectin and osteocalcin levels. The extracts of the materials generally had less effect, although one extract obtained from the glass-reinforced hydroxyapatite significantly down-regulated fibronectin. These in vitro studies thus suggest that there were only few differences overall in the growth of the cells directly on the glass-reinforced compared with the hydroxyapatite discs and also only relatively small effects of the extracts on the cells. However, the flow cytometry results suggest that both the materials and the extracts may have a potentially important influence on connective tissue production, and that these effects are both material- and antigen-specific.

Antigens↗

Microstructural dependence of Young's and shear moduli of P2O5 glass reinforced hydroxyapatite for biomedical applications.

P2O5 glass reinforced hydroxyapatite composite materials were prepared through a liquid-phase sintering process. Secondary phases, beta- and alpha-tricalcium phosphates (beta-TCP and alpha-TCP), were formed in the microstructure of the composites, due to the reaction between the liquid glassy phase and the hydroxyapatite matrix. The dynamic Young's modulus (E) and shear modulus (G) of these composites were determined using an impulse excitation method. By applying the Duckworth-Knudsen equation, the elastic property results were correlated with the relative proportion of beta-TCP and alpha-TCP phases and with the porosity percentage present in the microstructure. Glass reinforced hydroxyapatite composites showed lower Young's and shear moduli than unmodified hydroxyapatite, mainly due to the presence of beta-TCP phase. The Duckworth-Knudsen model demonstrated an exponential dependence of E and G modulus with porosity and mathematical equations were derived for composite materials with porosity correction factors (b) of 4.04 and 4.11, respectively, indicating that porosity largely decreased both E and G moduli.

Biocompatible Materials↗

Flow cytometry analysis of the effects of pre-immersion on the biocompatibility of glass-reinforced hydroxyapatite plasma-sprayed coatings.

Multilayered coatings composed of mixtures of HA and P2O5-based bioactive glasses are of potential clinical benefit in orthopaedic and dental surgery. Pre-immersion of these materials has been reported to further enhance their efficacy in vivo, although the precise biological effects of this treatment are not yet known. In this study we have therefore prepared double-layer plasma-sprayed coatings and evaluated the effects of pre-immersion on the growth and function of human osteosarcoma cells in vitro, using the MTT assay and flow cytometry analysis, respectively. The results showed that the increase in numbers of viable cells was the same or elevated following incubation on the pre-immersed HA and glass-reinforced HA coatings compared with the non-immersed materials. In addition, the expression of bone sialoprotein and fibronectin, two key connective tissue antigens, was up-regulated in cultures grown on the pre-immersed surfaces compared with the non-treated materials. Moreover, cell numbers and antigen expression both improved as the proportion of glass increased, particularly in the pre-immersed samples. Our findings thus suggest that the immersion treatment of these materials appeared to improve the response of these bone-like cells.

Biocompatible Materials↗

Flow cytometry analysis of effects of glass on response of osteosarcoma cells to plasma-sprayed hydroxyapatite/CaO-P(2)O(5) coatings.

Multilayered coatings composed of mixtures of hydroxyapatite (HA) and P(2)O(5)-based bioactive glasses offer potential clinical benefits in orthopedic and dental surgery. In this study double-layer plasma-sprayed coatings were prepared and the biological response evaluated in tissue culture using two human osteosarcoma cell lines, MG63 and HOS TE85 (HOS). The cells were cultured on the materials and the effects on cell growth were determined using a spectrophometric assay of a mitochondrial enzyme that is active in viable cells. While none of the materials influenced the growth of the MG63 cells, the HOS cells appeared to undergo less proliferation on all the HA materials. Flow cytometry analysis was carried out using rabbit antibodies against osteonectin, osteopontin, bone sialoprotein, fibronectin, and collagen type I to measure the effects of the materials on key cellular functions. The results showed that the materials downregulated the expression of these extracellular matrix antigens by MG63 cells whereas they had less effect on the HOS cells compared to the same cells incubated on a plastic surface. Notably, with both cell lines the composite with the higher percentage of glass restored the production of connective tissue proteins to levels that were more similar to those present in the control cells.

Animals↗

Hydrophobicity, surface tension, and zeta potential measurements of glass-reinforced hydroxyapatite composites.

Wettability and zeta potential studies were performed to characterize the hydrophobicity, surface tension, and surface charge of P2O5-glass-reinforced hydroxyapatite composites. Quantitative phase analysis was performed by the Rietveld method using GSAS software applied to X-ray diffractograms. Surface charge was assessed by zeta potential measurements. Protein adsorption studies were performed using vitronectin. Contact angles and surface tensions variation with time were determined by the sessile and pendent drop techniques, respectively, using ADSA-P software. The highest (-18.1 mV) and lowest (-28.7 mV) values of zeta potential were found for hydroxyapatite (HA) and beta-tricalcium phosphate (beta-TCP), respectively, with composite materials presenting values in between. All studied bioceramic materials showed similar solid surface tension. For HA and beta-TCP, solid surface tensions of 46.7 and 45.3 mJ/m2, respectively, were obtained, while composites presented intermediate surface tension values. The dispersive component of surface tension was the predominant one for all materials studied. Adhesion work values between the vitronectin solution and HA and beta-TCP were found to be 79.8 and 88.0 mJ/m2, respectively, while the 4.0 wt % glass composites showed slightly lower values than the 2.5 wt % ones. The presence of beta-TCP influenced surface charge, hydrophobicity, and protein adsorption of the glass-reinforced HA composites, and therefore indirectly affected cell-biomaterial interactions.

Adsorption↗

CaO-P2O5 glass hydroxyapatite double-layer plasma-sprayed coating: in vitro bioactivity evaluation.

Double-layer composite coatings composed of a P2O5-based glass/Ca10(PO4)6(OH)2 (HA) mixture top layer and a simple HA underlayer, on Ti-6Al-4V substrates, were prepared using a plasma-spraying technique. The in vitro bioactivity of these coatings was assessed by immersion testing in simulated body fluid. Both scanning electron microscopy (SEM) analysis and the ionic solution changes followed by atomic absorption spectroscopy and the molybdenum blue method demonstrated that these composite coatings induce a faster surface Ca-P layer formation than the simple HA coatings used as a control. X-ray photoelectron spectroscopy (XPS) analysis demonstrated that the Ca-P layer formed was apatite. The combination of SEM and XPS analyses showed that the apatite layer was a calcium-deficient hydroxyapatite with a Ca/P ranging from 1.3 to 1.4 with CO3(2-) groups contained in the structure.

Alloys↗

Glass-reinforced hydroxyapatite composites: secondary phase proportions and densification effects on biaxial bending strength.

CaO-P(2)O(5) glasses with additions of MgO and CaF(2) were used as a sintering aid of hydroxyapatite, and glass-reinforced hydroxyapatite composites obtained. Glasses promoted significant changes in the microstructure of the composites, namely with the formation of tricalcium phosphate secondary phases, beta and alpha-TCP. Quantitative phase analysis was performed by the Rietveld method using General Structure Analysis Software. Grain size measurements were carried out on SEM photomicrographs, using a planimetric procedure according to ASTM E 112-88. Flexural bending strength was determined from concentric ring-on-ring testing. Flexural bending strength (FBS) of glass-reinforced hydroxyapatite composites was found to be about twice or three times higher than that of unreinforced hydroxyapatite and tended to depend more on porosity and beta and alpha-TCP secondary phases, rather than on grain size. Traces of alpha-tricalcium phosphate significantly enhanced the strength of the composites. Using the rule of mixtures to estimate the zero porosity bending strength, the Duckworth-Knudsen model applied to the composites gave a porosity correction factor, b, with a value of 4.02. Weibull statistics were also used to analyze biaxial strength data and the level of reinforcement obtained by comparing failure probability for the composites and for the unreinforced hydroxyapatite. Lower activation energies for grain growth were observed for the composites compared to unreinforced hydroxyapatite, which should be attributed to the presence of a liquid glassy phase that promotes atomic diffusion during the sintering process.

Biocompatible Materials↗

Glass-reinforced hydroxyapatite composites: fracture toughness and hardness dependence on microstructural characteristics.

Fracture toughness and hardness properties of CaO-P2O5 glass-reinforced hydroxyapatite composites have been assessed using indentation techniques and results calculated according to Laugier and Evans' equations. Both properties showed to be dependent upon several microstructural characteristics, namely residual porosity and the percentage of secondary beta and alpha tricalcium phosphate phases in the structure of the composites. Composites presented a Palmqvist-type indentation crack system, which is the specific crack system addressed by Laugier's approach. Fracture toughness determinations according to Evan's equation, which is a universal one and adapted to both median and Palmqvist crack systems, did not correlate well with Laugier determinations.

Biocompatible Materials↗

In vitro growth and differentiation of osteoblast-like human bone marrow cells on glass reinforced hydroxyapatite plasma-sprayed coatings.

Human osteoblastic bone marrow cells were cultured for periods of up to 28 days in control conditions and on the surface of a glass reinforced hydroxyapatite composite (HA/G1) and commercial hydroxyapatite (HA) plasma-sprayed coatings, in the "as-received" condition and after immersion treatment in culture medium for 21 days. Cultures were characterized for total protein content and alkaline phosphatase activity. Scanning electron microscope analyses were performed on control cultures, seeded materials and materials incubated in the absence of cells. Culture media were analyzed for total and ionized calcium and phosphorus concentrations throughout the incubation period. Immersion of HA/G1 and HA coatings in culture medium resulted in significant alterations to the levels of calcium and phosphorus in the medium, leading to surface modifications. However, seeded material samples showed significant differences in the pattern of variation of the levels of these species. Cell proliferation was observed in the "as-received" HA/G1 composite, but cell mediated formation of mineral deposits was not proved. In contrast, "as-received" HA hardly supported cell growth. Previously immersed material samples showed cell proliferation and evidence of biological formation of mineral deposits. However, the HA/G1 composite presented better surface characteristics for cell growth as the behavior of bone marrow cells was closer to that observed in control cultures.

Journal Article↗

Flow cytometry for assessing biocompatibility.

Flow cytometry (FCM) was examined as a possible procedure for measuring in vitro the biocompatibility of implant materials for orthopedic and dental surgery. The human osteoblast-like cell line MG63 was grown on hydroxyapatite (HA) and P2O5 glass-reinforced HA composite discs and compared with the same cells grown on polystyrene culture dishes. While morphological observation at the light and electron microscopic levels showed no major deleterious effects, FCM indicated that cell size was somewhat reduced, particularly by growth on the HA composite. Morever, this material also appeared to delay the progression of the cells from the G0/G1 into the S phase of the cell cycle. In addition to this low level of inhibition of cell growth relative to control cultures, FCM analysis also demonstrated that the glass-reinforced HA caused some down-regulation of the expression of osteocalcin and fibronectin, two antigens which play a vital part in the integrity and function of bone and soft connective tissue, respectively. These results thus show, first, that although HA and the HA composite used in these experiments were generally biocompatible, they nevertheless had certain suboptimal effects on the cells; and second, that FCM could be a highly useful procedure for effectively screening and evaluating important biological responses to implant materials.

Biocompatible Materials↗

Glass-reinforced hydroxyapatite: a comprehensive study of the effect of glass composition on the crystallography of the composite.

Glass-reinforced HA composites were produced using phosphate-based glasses, and a structure refinement was carried out to determine the effect of the glass on the structure of the residual HA. Quantitative phase analysis showed that the glass causes some of the HA to decompose to beta-TCP and, at higher temperatures, to alpha-TCP. It also was indicated that when three phases were present, the formation of the alpha-TCP arose from decomposition of the beta-TCP and not from further decomposition of HA to alpha-TCP. The unit cell dimensions showed a decrease in the a axis and an increase in the c axis, giving an overall unit cell decrease in volume. There also was a significant effect based on the amount of glass added. The changes found in the composite containing the 4 wt% glass were attributed to the loss of carbonate and loss of hydroxyl. This was expected to cause shrinkage in the unit cell; however this was not seen, and therefore the major changes in the unit cell were attributed to the ions from the glass taking an interstitial role in the HA structure, thus not allowing the unit cell to shrink as much as expected.

Ceramics↗

Surface modifications of glass-reinforced hydroxyapatite composites.

Surface modifications of glass-reinforced hydroxyapatite composites immersed in a simulated physiological solution were studied using X-ray photoelectron spectroscopy, scanning electron microscopy and energy dispersive X-ray spectroscopy. In the first stages of the apatite formation process, calcium and silicon ions were leached out from the surface of the composites. After 12 days of immersion, apatite crystals were detected on the surface indicating bioactive behaviour. Sodium ions attributed to sodium sulphate were also found in the apatite layer. Bound water on the surface also increased with immersion time.

Biocompatible Materials↗

Microstructural characterization of glass-reinforced hydroxyapatite composites.

The influence of phosphate-based glasses and a bioactive silica glass on the sintering mechanism of hydroxyapatite was studied over a wide range of temperatures. The composites were microstructurally characterized using X-ray diffraction (XRD), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). Small additions of phosphate-based glasses proved to be beneficial to the sintering process and fully dense materials were obtained. A significant improvement in mechanical properties was achieved. beta-TCP and alpha-TCP were found in the microstructure depending on the sintering temperature. Additions of bioactive glass led to the development of calcium phosphate silicate.

Biocompatible Materials↗