PubMed HealthSearch

Biomedical subjects

F J Pinto

Publications and source records attributed to F J Pinto.

16 recordsLinked to original sources

Systemic venous flow during cardiac surgery examined by intraoperative transesophageal echocardiography.

Patterns of systemic venous return change after cardiac surgery. However, the exact timing and underlying mechanisms are not well understood. To analyze these changes transesophageal echocardiography was used to evaluate 21 patients (mean age 56 +/- 17 years) during cardiac surgery. Eleven patients underwent coronary bypass grafting, 2 had ablation of accessory bundles, 4 had mitral and 4 had aortic valve replacements. All were in sinus rhythm and were undergoing their first cardiac operation. Hepatic and pulmonary venous flow, tricuspid annular motion, and signs of tricuspid regurgitation were recorded sequentially 5 times: (A) with chest closed, (B) with chest open and pericardium closed, (C) with both chest and pericardium open, (D) after cardiopulmonary bypass with chest open, and (E) after cardiopulmonary bypass with chest closed. The hepatic venous Doppler flow velocity integrals (cm) changed, from stage A to stage E: systolic flow decreased from 5.9 +/- 5.2 to 2.2 +/- 1.4 (p less than 0.01); diastolic flow increased from 3.1 +/- 1.5 to 4.8 +/- 3.3 (p less than 0.001); and systolic to diastolic ratio decreased from 2.0 +/- 1.2 to 0.7 +/- 0.6 (p less than 0.001). Reversed flow at the end of ventricular systole was present in 9 patients (43%) at stage A and in all patients at stage E. Decreased tricuspid annular motion was noted in all but 1 patient after cardiopulmonary bypass. No patient presented significant tricuspid regurgitation at any stage. In conclusion, the significant change in the pattern of systemic venous return after open heart surgery is not due to opening of the chest wall or parietal pericardium, or to tricuspid regurgitation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Nitroglycerin-induced coronary vasodilation in cardiac transplant recipients. Evaluation with in vivo intracoronary ultrasound.

BACKGROUND: Coronary artery vasomotion is altered after cardiac transplantation. The impact of accelerated transplant coronary atherosclerosis and myocardial rejection on vasomotion is not well understood. Intravascular ultrasound is a new imaging method with the ability to study real-time changes in coronary artery dimensions. METHODS AND RESULTS: Epicardial coronary artery response to nitroglycerin was studied in 32 cardiac transplant recipients (age, 47 +/- 11 years) 3 weeks to 10 years after transplantation with intracoronary ultrasound. Cross-sectional luminal area and diameter were measured at a fixed position in the left anterior descending artery immediately before and every 30 seconds for 5 minutes after 0.4 mg of sublingual nitroglycerin. Cross-sectional area increased from a baseline of 13.1 +/- 3.9 mm2 to 15.8 +/- 3.9 mm2 at maximal vasodilation; luminal diameter increased from 4.0 +/- 0.6 mm to 4.5 +/- 0.6 mm. This increase reached statistical significance (p less than 0.001) at 1.5 minutes after administration of nitroglycerin; mean maximum increase occurred at 4.5 minutes (24% for cross-sectional area and 11% for luminal diameter). Patients with biopsy-proven mild or moderate concurrent rejection had a significantly blunted vasodilatory response versus the nonrejection group (9% versus 27% for cross-sectional area, p less than 0.04), although a vasodilatory effect was still present. Nitroglycerin response was well preserved in patients up to 10 years after transplantation; however, there was a trend toward a decreased response in patients studied immediately after transplantation (21% versus 29%, p = 0.37). Coronary intimal thickness, as measured by ultrasound, had no impact on the vasodilatory response (R = 0.23, p = 0.34). CONCLUSIONS: Vasodilatory response to nitroglycerin in cardiac transplant recipients is attenuated during episodes of cardiac rejection. This response is preserved in long-term survivors and is independent of the degree of intimal thickening. Intravascular ultrasound provides a new method to document real-time epicardial coronary vasomotion.

Adult

Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of "angiographically silent" intimal thickening.

BACKGROUND: Accelerated coronary atherosclerosis is a major factor limiting allograft longevity in cardiac transplant recipients. Histopathology studies have demonstrated the insensitivity of coronary angiography for detecting early atheromatous disease in this patient population. Intracoronary ultrasound is a new imaging technique that provides characterization of vessel wall morphology. The purpose of this study was to compare in vivo intracoronary ultrasound with angiography in cardiac transplant recipients. METHODS AND RESULTS: The left anterior descending coronary artery was studied with intracoronary ultrasound in 80 cardiac transplant recipients at the time of routine screening coronary angiography 2 weeks to 13 years after transplantation. A mean and index of intimal thickening were obtained at four coronary sites. Intimal proliferation was classified as minimal, mild, moderate, or severe according to thickness and degree of vessel circumference involved. Twenty patients were studied within 1 month of transplantation and had no angiographic evidence of coronary disease. An intimal layer was visualized by ultrasound in only 13 of these 20 presumably normal hearts. The 60 patients studied 1 year or more after transplantation all had at least minimal intimal thickening. Twenty-one patients (35%) showed minimal or mild, 17 (28%) moderate, and 21 (35%) severe thickening. Forty-two of these 60 patients had angiographically normal coronary arteries, 21 (50%) of whom had either moderate or severe thickening. All 18 patients with angiographic evidence of coronary disease had moderate or severe intimal thickening, but there was no statistically significant difference in intimal thickness or index when compared with the patients with moderate or severe proliferation and normal angiograms (thickness, 0.53 +/- 0.35 mm versus 0.64 +/- 0.30 mm, p = NS; index, 0.28 +/- 0.10 versus 0.34 +/- 0.10, p = NS). CONCLUSIONS: The majority of patients 1 or more years after cardiac transplantation have ultrasound evidence of intimal thickening not apparent by angiography. Intracoronary ultrasound offers early detection and quantitation of transplant coronary disease and provides characterization of vessel wall morphology, which may prove to be a prognostic marker of disease.

Coronary Angiography

Intravascular ultrasound imaging of coronary arteries. Is three layers the norm?

BACKGROUND: The purpose of this study was to evaluate the significance of the three-layered appearance of coronary arteries in adolescence and adults from intravascular ultrasound scans and to correlate these observations with histopathology. METHODS AND RESULTS: Sixteen intact hearts were excised at autopsy from patients with no clinical history of coronary artery disease. The patients' ages ranged from 13 to 55 years. A 30-MHz ultrasound imaging catheter was used to obtain images throughout the epicardial coronary vasculature. A total of 72 image cross sections was marked by epivascular sutures, and the corresponding histological sections were examined. Ultrasound images were classified into two groups: images exhibiting three-layered appearance and images without distinct layering. Histological analysis revealed a significantly greater degree of intimal thickening in segments with three layers (243 +/- 105 microns) than in nonlayered segments (112 +/- 55 microns). Discriminant analysis of these data predicted the threshold between the two groups to be 178 microns. Measurements of medial thickness were not different between these two groups (235 +/- 61 versus 210 +/- 76 microns). In the nonlayered group, the average patient age was 27.1 +/- 8.5 years, whereas in the three-layered groups, the average age was 42.8 +/- 9.8 years. CONCLUSIONS: The intracoronary ultrasound image appearance of young, morphologically normal coronary artery walls is homogeneous without layering. A three-layered appearance suggests the presence of at least 178 microns of intimal thickening and is seen more frequently with advancing age.

Adolescent

Detection of coronary atherosclerosis in young adult hearts using intravascular ultrasound.

BACKGROUND: Coronary atherosclerosis has been demonstrated in young adults by postmortem pathology. Angiographic evaluation of coronary disease in young adults is limited by ethical issues and the insensitivity of angiography for detecting early pathology. Catheter-based intracoronary ultrasound has proven useful both in detecting and quantitating coronary disease, but the ultrasound appearance of young, angiographically normal, coronary arteries has not been well defined. METHODS AND RESULTS: Twenty-five subjects were examined with intracoronary ultrasound within 1 month of cardiac transplantation. Mean age of the donor hearts was 28 years (range, 14-43 years). Measurements of an index of intimal thickening were obtained at four left anterior descending coronary artery sites in each patient. All study patients had angiographically normal coronary arteries. Ultrasound in 14 subjects demonstrated a three-layered appearance of the coronary vessel wall with a mean intimal index of 0.16 +/- 0.07. The other 10 subjects, including all donors under the age of 25 years, had coronary vessel wall layers too thin to be imaged separately at the 30-MHz sound frequency. Five subjects had ultrasound evidence of focal intimal thickening greater than 500 microns. The donors of these hearts each had risk factors for coronary artery disease. Two subjects died within 5 weeks of their ultrasound study. Histological measurements of the vessel wall layers were similar to the corresponding ultrasound values. CONCLUSIONS: This study provides a reference for the intravascular ultrasound appearance of young adult coronary arteries and confirms pathology findings that young subjects with angiographically normal vessels have a range of coronary intimal thickening, which includes occasional evidence of focal, early atheromatous lesions.

Adult

Aspects of mechanical ventilation affecting interatrial shunt flow during general anesthesia.

Intraoperative transesophageal echocardiography was used to study the incidence of flow-patent foramen ovale in 33 normal, healthy patients (ASA physical status I) undergoing general anesthesia in the supine position for nonthoracic surgical procedures. Echocardiographic contrast was injected intravenously during mechanical ventilation in the presence of 0, 5, 10, 15, or 19 cm H2O positive end-expiratory pressure (PEEP). A final test was performed during the release of 19 cm H2O PEEP. The presence of a flow-patent foramen ovale was detected when the injected echo targets were observed crossing the interatrial septum from right to left. Most interesting, 3 of 33 patients developed a right-to-left shunt that was first detected with the steady application of 10 (1 patient) or 15 cm H2O PEEP (2 patients). In all three cases, the shunt flow was accentuated on the release of PEEP; however, no additional cases were detected using this respiratory maneuver. These cases represent the first demonstration of right-to-left interatrial shunting evoked as the result of the sustained application of PEEP. This study also revealed a lower than expected incidence of flow-patent foramen ovale (9%) when measured during general anesthesia and positive pressure ventilation with or without PEEP.

Adult

Hepatic venous flow assessed by transesophageal echocardiography.

Systemic venous flow patterns are easily assessed by transthoracic echocardiography for evaluation of right heart dynamics. However, the transthoracic approach cannot be used in patients undergoing thoracic surgery. The present study describes a method for obtaining hepatic venous flow velocity with transesophageal Doppler echocardiography. Twenty-nine patients were studied with transthoracic echocardiography just before cardiac surgery and with transesophageal echocardiography during surgery. Hepatic venous flow velocity recordings were obtained in 14 of 29 patients with the transthoracic and in all 29 with the transesophageal approach. Timing of flow pattern was similar with the two methods, but recordings obtained with transesophageal echocardiography were inverted compared with those obtained with transthoracic echocardiography as a result of the difference in probe location in relation to flow direction. The time-velocity integrals obtained with the two techniques did not differ significantly; for the transthoracic and transesophageal approaches, they were, respectively, 7.3 +/- 3.4 versus 5.7 +/- 4.4 for systolic flow; 1.0 +/- 1.0 versus 0.5 +/- 0.6 for end-systolic flow reversal; 4.7 +/- 2.3 versus 3.7 +/- 1.7 for diastolic flow; 2.0 +/- 1.8 versus 1.5 +/- 1.5 for atrial flow reversal and 1.9 +/- 1.0 versus 1.7 +/- 1.1 for systolic/diastolic ratio. In conclusion, hepatic venous flow values are obtained more frequently and with better quality by transesophageal than by transthoracic echocardiography. The flow patterns and velocity integrals are similar with both methods and previous experience with transthoracic echocardiography should be applicable to the transesophageal technique. Transesophageal Doppler echocardiography therefore has potential for studying right heart dynamics during anesthesia and surgery.

Anesthesia, General

Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Angiography

Disorders of hypopigmentation in children.

The most common disorders of hypopigmentation in children are pityriasis alba, vitiligo, nevus depigmentosus, and tinea versicolor. Pityriasis alba usually presents as ill defined, scaly patches of hypomelanosis on the cheeks of children with an atopic diathesis. The face is also a favored site for vitiligo, but the distribution is periorificial, and the pigment loss is complete because of a destruction of melanocytes. Vitiligo is an acquired, progressive disorder in contrast to nevus depigmentosus, which is a stable, congenital leukoderma. The localized form of nevus depigmentosus must be distinguished from an ash leaf spot, the earliest cutaneous manifestation of tuberous sclerosis, whereas the systematized form may be confused with hypomelanosis of Ito, another neurocutaneous disorder. The lesions of tinea versicolor favor the upper trunk of adolescents, and potassium hydroxide examination of the associated scale reveals hyphal and yeast forms of P. orbiculare. Any inflammatory process in the skin such as dermatitis or psoriasis can resolve with areas of hypopigmentation.

Adolescent

Abnormal right heart filling after cardiac surgery: time course and mechanisms.

OBJECTIVE: To study the time course and underlying mechanisms of right heart filling after cardiac surgery. DESIGN: A prospective observational study of adult patients undergoing cardiac surgery. SETTING: Echocardiography laboratory of the Stanford University Medical Center. PATIENTS: Twenty six patients (mean age 54.9) undergoing cardiac surgery were studied before and two days, one week, six weeks, and six months after cardiac surgery. MAIN OUTCOME MEASURES: Flow in the hepatic veins and superior vena cava, tricuspid and mitral annulus motion, signs of tricuspid regurgitation, and right ventricular size were assessed by echocardiography. RESULTS: Right heart filling, expressed as the ratio of systolic to diastolic forward flow Doppler velocity integrals in the superior vena cava and by tricuspid annulus motion, decreased in parallel from before surgery baseline values of 3.5 (SD 3.1) and 21.9 (3.4) mm, respectively to 0.2 (0.1) and 8.1 (2.3) mm two days after operation. A gradual increase towards baseline values was noted after six months, to 1.4 (1.3) and 15.1 (2.3) mm respectively; however, these values were still significantly less than those before operation. Similar changes were seen in the hepatic venous flow pattern. The decrease in total tricuspid annulus motion was most pronounced in its lateral segment and the atrial component of the tricuspid annulus motion showed similar changes. CONCLUSIONS: The pronounced decrease in tricuspid annulus motion during the early postoperative period suggests right atrial and right ventricular dysfunction as mechanisms responsible for the early changes seen. The progressive return to a normal venous filling pattern and the partial recovery of annular motion six months after operation further support the influence of the above mechanisms, as well as their resolution with time. The persistent flow abnormalities and compromised motion of the free aspects of the tricuspid annulus, however, suggest long term tethering of the right heart wall.

Adult

Tricuspid annular motion.

Triscupid annular motion is related to right ventricular systolic function in the same way mitral annulus motion is related to left ventricular function. Tricuspid annular excursion reflects the longitudinal motion of the right ventricle, and the systolic descent of the anulus correlates with systolic venous inflow to the right atrium. However, it has not been shown clearly how to reproducibly quantify this motion. Therefore we describe a method to measure triscuspid annular motion using two-dimensional oriented M-mode echocardiography from the apical view. We studied a group of 10 normal subjects (mean age, 28.7 years; range, 25 to 38 years) and a group of 29 patients (mean age, 57.2 years; range, 20 to 84 years) with disease of the left side of the heart but no evidence of involvement of the right side of the heart. In each subject, tricuspid and mitral annular motion were measured respectively at their lateral, septal or medial, anterior, and posterior margin points. The total tricuspid annular motion for normal subjects was, as follows: lateral, 24.9 +/- 3.5 mm; medial, 20.1 +/- 2.5 mm; anterior, 21.6 +/- 3.8 mm; and posterior, 22.3 +/- 2.3 mm. Interobserver and intraobserver variability was low, with a coefficient of variance for the different annular points ranging from 6.19% to 11.56% between observers and from 4.10% to 7.26% within observer. We conclude that it is possible to measure tricuspid annular motion with this method in a reproducible way and to use it as a diagnostic tool in evaluating function of the right side of the heart.

Adult